Yakup Daşdemirli

Yakup Daşdemirli

Auto-generated profile, based on publicly available information

Yakup Daşdemirli

Karabuk University

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2026 in Russian Journal of Electrochemistry
Verified
Journal Article
Closed access
SBShokhrukhbek Bakhramov
Shokhrukhbek Bakhramov
YDYakup Daşdemirli
Yakup Daşdemirli
MYMustafa YASAR
Mustafa YASAR

20 February 2026 in Gazi University Journal of Science
Verified
Journal Article
Closed access
YDYakup Daşdemirli
Yakup Daşdemirli
UMUlaş Matik
Ulaş Matik
MKMuhammet Kayfeci
Muhammet Kayfeci
This study investigates the thermal and mass transfer behaviors of the LaNi5 alloy during hydrogen absorption after applying three different surface coatings. To enhance heat transfer within the metal hydride reactor and evaluate its performance, three reactor designs were developed: a reference design, a design incorporating a central heat pipe, and an advanced design equipped with a finned heat pipe to improve heat distribution. LaNi5 powders were ground for one hour using mechanical milling and then coated under controlled conditions to produce copper-coated, Cu/Ag double-layer-coated, and silver-coated samples. The findings demonstrate that a homogeneous and stable Cu/Ag duplex coating can be successfully applied to LaNi5 powders. This offers the potential to enhance heat transfer in hydrogen storage systems by improving the thermal behavior of metal hydrides. The thermal conductivity of uncoated and coated powders was measured experimentally. Experiments confirmed that higher operating pressures resulted in improved hydrogen absorption. Not only did enhanced thermal conductivity accelerate hydrogen absorption, but it also reduced local temperature spikes, promoting a more uniform temperature distribution throughout the reactor. These values were then used in a three-dimensional model to simulate the hydrogen absorption process. This model assessed the storage capacity of hydrogen and the temperature distribution over time at various operating pressures (3, 6, 9, 10, 12, and 15 bar). Using heat pipes and fins significantly enhanced heat transfer within the reactor, resulting in improved overall performance.

17 July 2026 in Journal of Thermal Engineering
Verified
Journal Article
Open access
PDF file
ADAbdullah DAĞDEVİREN
Abdullah DAĞDEVİREN
YDYakup Daşdemirli
Yakup Daşdemirli
BABahadır Acar
Bahadır Acar
MMMegen Guled Mohammed
Megen Guled Mohammed
ÖIÖzgür İnAnç
Özgür İnAnç
In this study, the freeze-drying (FD) behavior of ginger (Zingiber officinale) at thicknesses of 5 and 7 mm was analyzed experimentally and statistically. The drying process was evaluated using ten empirical models to decide which was most proper for predicting weight reduction. Among the evaluated models, the Logarithmic Model was the most correct in describing the drying kinetics for both sample thicknesses, showing the lowest error rates of 8.39% for 5 mm samples and 8.42% for 7 mm samples. The 5 mm samples had statistical parameters of correlation coefficient (R2) = 0.9902, chi-square (X2) = 1.402×10-3 and root mean square error (RMSE) = 0.03211. The 7 mm samples had R2 = 0.9986, X2= 1.153×10-3, and RMSE = 0.03411. Additionally, the calculated effective moisture diffusion coefficient (Deff) values for 5 mm and 7 mm were 2.075×10-7 m2/s and 4.079×10-10 m2/s, respectively, which are in line with the values reported for different food items.

29 December 2025 in International Journal of Energy Studies
Verified
Journal Article
Closed access
MKMuhammet Kayfeci
Muhammet Kayfeci
UMUlaş Matik
Ulaş Matik
YDYakup Daşdemirli
Yakup Daşdemirli
The low thermal conductivity of LaNi₅-based metal hydride powders limits efficient heat removal during hydrogen charging and discharging, thereby reducing overall system efficiency. This study examines the application of a Cu/Ag duplex coating on LaNi₅ metal hydride particles to minimize interparticle thermal resistance and improve thermal conductivity. LaNi₅ particles were first ground in a ball mill for one hour, then coated with Cu via a chemical reduction method in a copper sulfate-containing solution. The Cu/Ag duplex coating was subsequently formed by reducing the Cu-coated surfaces with [Ag(NH₃)₂]⁺ complex ions in a solution containing potassium sodium tartrate (KNaC₄H₄O₆·4H₂O). The structural, morphological, and thermal properties of the coatings were characterized using several techniques. Scanning electron microscopy (SEM) was used to analyze the surface morphology, while energy dispersive X-Ray spectroscopy (EDX) confirmed the elemental composition. X-ray diffraction (XRD) was used to determine the phase structure. Differential scanning calorimetry (DSC) was performed to evaluate thermal stability and potential structural transformations. The results show that a uniform and stable Cu/Ag duplex coating can be successfully applied to LaNi5 powders. DSC analysis further reveals that the duplex coating improves the thermal behavior of metal hydrides, offering a promising method for enhancing heat transfer in hydrogen storage systems.

29 December 2025 in International Journal of Energy Studies
Verified
Journal Article
Closed access
MKMuhammet Kayfeci
Muhammet Kayfeci
UMUlaş Matik
Ulaş Matik
YDYakup Daşdemirli
Yakup Daşdemirli
The thermal and mass behavior of LaNi5 alloy, a metal hydride-based hydrogen storage material, modified with different surface coating types was investigated during the hydrogen storage process. Based on the experimentally measured thermal conductivity coefficients, four different sample groups were created: Sample 1 – uncoated LaNi5 powder, Sample 2 – copper-coated LaNi5, Sample 3 – copper/silver double-layer-coated LaNi5, and Sample 4 – silver-coated LaNi5. The thermal conductivity values of each sample were determined, and these data were evaluated in a three-dimensional model developed in COMSOL Multiphysics software. During the modeling process, the amount of hydrogen stored in the metal hydride reactor under different operating pressures (4 bar, 8 bar, and 12 bar) was calculated; the transient temperature distribution and hydrogen concentration profiles of the system were analyzed with time. It was shown that the coated samples – especially the Cu, Cu/Ag, and Ag coated samples – had higher thermal conductivities than the uncoated sample. This increase contributes to the shortening of the hydrogen absorption time and the limitation of local temperature increases, resulting in a more homogeneous temperature distribution in the system.