This article investigates the challenges of designing 6.78 MHz multi-kilowatt H-bridge inverters with high-voltage silicon carbide (SiC) and gallium nitride (GaN) devices, while comparing their performance. First, a design methodology for MHz-switching H-bridge inverters is proposed, addressing critical aspects such as switch selection, gate driver supply design, parasitic inductance minimization, zero-voltage switching, and thermal management. Three 1st-generation inverters are then implemented using 650 V wide-bandgap devices: SiC MOSFET (C3M0060065K), GaN field-effect transistor (FET) (TP65H070G4PS), and GaN FET (GS66506T). In multi-MHz and multi-kW testing, the SiC-based inverter reaches a switching limit of 4 MHz at 3.874 kW but suffers from gate driver overpowering and thermal constraints. The TP65H070G4PS GaN inverter achieves the optimal frequency-power balance, delivering 2.026 kW at 6.78 MHz, though it exhibits significant oscillations at low dc voltages (<250 V). Meanwhile, the GS66506T GaN inverter demonstrates superior high-frequency performance but struggles with thermal dissipation, attaining 1.105 kW at 6.78 MHz. To enable reliable 6.78 MHz power conversion, a 2nd-generation design is developed using enhanced SiC (C3M0120100K) and GaN (GS66508T) switches and evaluated in a 6.78-MHz and 2.4-kW isolated dc–dc converter. These inverters achieve 2.448 kW with 93.63% dc–dc efficiency for the SiC inverter, while the GaN variant reaches 2.483 kW at 95.17% efficiency. This marks the first practical demonstration of a multi-kW SiC H-bridge inverter operating at 6.78 MHz and highlights the performance tradeoffs between SiC and GaN technologies.
21 August 2025 in IEEE Transactions on Industry Applications
Front-end monitoring of coupling and load conditions is vital for next-generation inductive power transfer (IPT) systems, especially with the shift to new control paradigms. Existing monitoring schemes often face challenges such as non-resonant frequency identification, low accuracy, extensive data measurement requirements, and limited operating conditions. To tackle these issues, this paper proposes a resonant-frequency-based dynamic front-end monitoring strategy for typical series-series (SS)-compensated IPT systems. This method is grounded in the small-signal model of the SS-compensated IPT system, allowing for the estimation of mutual inductance and load conditions based solely on the dynamic responses of the transmitter-side current, without requiring communication feedback from the receiver. A key advantage of this strategy is its ability to accurately and rapidly determine mutual inductance and load conditions at resonant frequency during the initial soft starting phase. Both simulation and experimental results demonstrate the superior performance of the proposed monitoring strategy compared to conventional non-resonant frequency-based steady-state methods.
This paper introduces a communication-free series-series (SS) inductive power transfer (IPT) system designed for electric vehicle (EV) charging, featuring three key advantages: 1) exceptional power regulatability adapting to the charging profiles of EV battery, 2) high tolerance to misalignment, ensuring stable charging power under misaligned conditions, and 3) bidirectional power transfer capability. The phase angle Δθ between the AC output current and voltage is controlled by the proposed vehicle-side active rectifier. With 0≤Δθ<90°, the IPT system works in grid-to-vehicle (G2V) charging mode, and the output current/voltage/power can be monotonously regulated by adjusting Δθ, achieving constant-current (CC) and constant-voltage (CV) charging as well as high misalignment tolerance. With 90°<Δθ≤180°, the IPT system works in vehicle-to-grid (V2G) discharging mode, contributing to bidirectional power transfer. All the functions are achieved by the vehicle-side active rectifier without the involvement of grid-sided converters, consequently removing the dual-sided communication and the front/back-end converters. To validate the proposed design, a 3kW IPT prototype is implemented. Experimental results demonstrate a CC charging limit of 8.1A, a CV charging limit of 400V, and a ±100 mm misalignment tolerance in both x and y directions in G2V mode, and the maximum G2V efficiency achieves 96.9% with 3.02kW at a distance of 180mm (k=0.237). With Δθ=153°, 3kW V2G discharging is verified, and a maximum V2G efficiency of 96.59% with 2.01kW is achieved.