Yonghao Zhou

Yonghao Zhou

Auto-generated profile, based on publicly available information

Yonghao Zhou

School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
LCLin Chang
Lin Chang
YZYonghao Zhou
Yonghao Zhou
YYYingjie Yu
Yingjie Yu

20 April 2024 in Optics & Laser Technology
Verified
Journal Article
Closed access
LCLin Chang
Lin Chang
JGJiehua Gao
Jiehua Gao
BLBing Li
Bing Li
YZYonghao Zhou
Yonghao Zhou
YYYingjie Yu
Yingjie Yu

3 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YZYonghao Zhou
Yonghao Zhou
BSBin Shen
Bin Shen
XLXingyu Lin
Xingyu Lin
LCLin Chang
Lin Chang
JLJiaoyang LI
Jiaoyang LI
YYYingjie Yu
Yingjie Yu
The fringe analysis method, using phase modulation with wavelength tuning, is widely used in profiling the surfaces and thickness variation in optical flat interferometry. However, the measurement accuracy may deteriorate owing to the phase demodulation errors resulting from the offsets in frequency estimation due to the unavoidable spectrum leakage. To address this challenge, a dual-window all-phase harmonic demodulation on wavelength tuning interferometry (Dwa-WTI) is developed to improve the measurement accuracy of surface profiles and thickness variation of the optical flat. The Dwa-WTI compensates for the effect of the sampling sequence on the spectrum by synthesizing the new interferograms, which effectively suppresses the undesirable error of phase demodulation. With the developed Dwa-WTI, the initial phase of the wavefront distribution at the spectrum peak of the synthesized sequence is independent of the frequency offset. The reliability of the Dwa-WTI has been validated by numerical simulations and experiments. In experiments, the optical flats with thickness of 5 mm, 10 mm and 30 mm are measured. The difference of peak-to-valley (PV) and root-mean-square (RMS) for the profiles of the thickness variation, front and rear surfaces are compared in repeated experiments. Meanwhile, the measurements under different spatial carriers are compared to assess the stability of the Dwa-WTI and the relative standard deviation (RSD) for the root-mean-square of the theoretical error (RMSTE) is about 0.085.

27 February 2025 in Advances in Manufacturing
Verified
Journal Article
Closed access
PDF file
YZYong-Hao Zhou
Yong-Hao Zhou
BSBin Shen
Bin Shen
LCLin Chang
Lin Chang
SVSergiy Valyukh
Sergiy Valyukh
YYYingjie Yu
Yingjie Yu

29 July 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YZYonghao Zhou
Yonghao Zhou
LPLeyuan Peng
Leyuan Peng
JMJiaxin Mo
Jiaxin Mo
YYYingjie Yu
Yingjie Yu
Wavelength-tuning interferometry is essential instrument to measure the surface profile of transparent plates in semiconductor lithography field. The wavelength-tuning range of the laser is a key parameter in interferometry. An insufficient tuning range can cause the interference signal being sampled under non-full-period, resulting in the inability to separate the surface profile from the superimposed interferograms. To tackle these challenges, a synchronous multi-surface interferometry algorithm based on rotational invariance under non-full-period sampling (SMSI-RIns) is developed to measure the optical thickness variation, front, and rear surface profile of transparent plates in this paper. The proposed SMSI-RIns first identifies the harmonic components from the superimposed interferogram. To mitigate the nonlinear of phase demodulation error by the misalignment of the air gap between the test and the reference of the interferometer, the harmonic frequencies of the interference signals are determined using rotation operator and total least squares in the signal subspace. Then, an iterative framework for phase demodulation is developed to determine the initial phase of the surface profile and suppress the ripple caused by harmonic crosstalk in the reconstructed one. Numerical simulations incorporating multiple factors is performed and thousands of Monte Carlo simulations also confirm the robustness of the proposed SMSI-RIns under non-full-period. Experiments with different factors on transparent plates with a thickness of 1 mm are conducted to validate the effectiveness of the proposed SMSI-RIns. The standard deviations of peak-to-valley (PV) and root-mean-square (RMS) are better than 0.0091 λ0 and 0.45×10-4 λ0 (λ0 = 632.8 nm) at 90%, 80%, 70%, 60%, and 50% of the full-period sampling, respectively. Moreover, the relative error between the PV and RMS of the proposed SMSI-RIns over 100 GHz wavelength-tuning range and the ZYGO VeriFire MST over 200 GHz for a transparent plate with a thickness of 0.6 mm is less than 5% and 2%.