16 November 2022 in IEEE Transactions on Medical Imaging
Optical Coherence Tomography Angiography (OCTA), a functional extension of OCT, has the potential to replace most invasive fluorescein angiography (FA) exams in ophthalmology. So far, OCTA’s field of view is however still lacking behind fluorescence fundus photography techniques. This is problematic, because many retinal diseases manifest at an early stage by changes of the peripheral retinal capillary network. It is therefore desirable to expand OCTA’s field of view to match that of ultra-widefield fundus cameras. We present a custom developed clinical high-speed swept-source OCT (SS-OCT) system operating at an acquisition rate 8-16 times faster than today’s state-of-the-art commercially available OCTA devices. Its speed allows us to capture ultra-wide fields of view of up to 90 degrees with an unprecedented sampling density and hence extraordinary resolution by merging two single shot scans with 60 degrees in diameter. To further enhance the visual appearance of the angiograms, we developed for the first time a three-dimensional deep learning based algorithm for denoising volumetric OCTA data sets. We showcase its imaging performance and clinical usability by presenting images of patients suffering from diabetic retinopathy.
13 January 2025 in IEEE Transactions on Medical Imaging
Four-dimensional microscope-integrated optical coherence tomography enables volumetric imaging of tissue structures and tool-tissue interactions in ophthalmic surgery at interactive update rates. This enables surgeons to undertake particular surgical steps under four-dimensional optical coherence tomography (4D OCT) guidance. However, current 4D OCT systems are limited by their field of view and signal quality. Both are attributable to the emphasis on high volume acquisition rates, which is critical for smooth visual perception by the surgeon. Existing 3D volume mosaicing methods are developed in the context of diagnostic imaging and do not take dynamic surgical interactions and real-time processing into account. In this paper, we propose a novel volume mosaicing and visualization methodology that not only aims at leveraging the temporal information to overcome some of the current limitations and imaging artifacts of 4D OCT, but also is aware of the surgical context and dynamic instrument motion implicitly during registration and explicitly for visualization. We propose a rapid 4-degrees of freedom volume registration, integrating an innovative approach for volume mosaicing that takes temporal recency and semantic information into account for enhanced surgical visualization. Our experiments on 4D OCT datasets demonstrate high registration accuracy and illustrate the benefits for visualization by reducing imaging artifacts and dynamically expanding the surgical view.
2 April 2024 in Translational Vision Science & Technology
JMJennifer-Magdalena Masch
+5
Purpose: To investigate the visualization capabilities of high-speed swept-source optical coherence tomography (SS-OCT) in cataract surgery. Methods: Cataract surgery was simulated in wet labs with ex vivo porcine eyes. Each phase of the surgery was visualized with a novel surgical microscope-integrated SS-OCT with a variable imaging speed of over 1 million A-scans per second. It was designed to provide four-dimensional (4D) live-volumetric videos, live B-scans, and volume capture scans. Results: Four-dimensional videos, B-scans, and volume capture scans of corneal incision, ophthalmic viscosurgical device injection, capsulorrhexis, phacoemulsification, intraocular lens (IOL) injection, and position of unfolded IOL in the capsular bag were recorded. The flexibility of the SS-OCT system allowed us to tailor the scanning parameters to meet the specific demands of dynamic surgical steps and static pauses. The entire length of the eye was recorded in a single scan, and unfolding of the IOL was visualized dynamically. Conclusions: The presented novel visualization method for fast ophthalmic surgical microscope-integrated intraoperative OCT imaging in cataract surgery allowed the visualization of all major steps of the procedure by achieving large imaging depths covering the entire eye and high acquisition speeds enabling live volumetric 4D-OCT imaging. This promising technology may become an integral part of routine and advanced robotic-assisted cataract surgery in the future. Translational Relevance: We demonstrate the visualization capabilities of a cutting edge swept-source OCT system integrated into an ophthalmic surgical microscope during cataract surgery.
31 August 2024 in American Journal of Ophthalmology
To introduce and validate a novel substantially lower-priced and rapid swept-source investigational optical biometer in healthy and cataractous eyes, using a thermally tuned laser diode used extensively in cell phones and data communication as an alternative swept source. Prospective accuracy, validity, and reliability analysis. A total of 60 eyes of 59 subjects (29 eyes of 29 healthy subjects and 31 eyes of 30 cataract patients) were enrolled in a prospective comparative study at the Vienna General Hospital between August 2021 and April 2023. Averaged intraocular distances were acquired in 2.5 seconds from datasets consisting of 5000 consecutive A-scans at a single position by a low-cost swept-source optical biometry (SSOB) system. Instrument repeatability was assessed via standard deviations (SDs) and coefficients of variation (CoVs) of parameters such as axial length (AL), anterior chamber depth (ACD), lens thickness (LT), and central corneal thickness (CCT). Healthy subjects and cataract patients were subsequently measured on the same day with the SSOB and a referential partial coherence interferometry (PCI) biometer (IOLMaster 500) to establish AL inter-device correlation (r) for instrument calibration. AL and ACD as shared parameters between both biometers were evaluated for their limits of agreements (LoA) using Bland-Altman analysis. Repeated measurements of AL, ACD, LT, and CCT revealed SDs of 18 µm, 12 µm, 12 µm, and 10 µm, respectively. All parameters except for CCT had a COV 0.99). The 95% LoAs between both biometers were -0.14 to 0.13 mm for AL and -0.28 to 0.25 mm for ACD. Optical biometry using a thermally tunable VCSEL swept-source light source has the potential to provide clinically relevant biometric parameters at an unprecedented 100-fold lower price point than currently used state-of-the-art optical biometers, paving the way for compact devices in remote care settings.
17 July 2026 in Medical Image Analysis
In Fourier-domain optical coherence tomography (FD-OCT) imaging, saturation of the data acquisition chain leads to loss of information by clipping the spectral interferograms. When reconstructed, affected depth profiles are degraded by bright axial lines or periodical patterns which mask the underlying information and thereby affect clinical utility. In this work, we propose an approach to faithfully recover the distorted information from saturated FD-OCT scans based on physical insights. For this purpose, genesis and appearance of saturation artifacts are analyzed, revealing a wavelength-dependency within individual interferograms. We propose to use this knowledge in a dual manner: Firstly, we present a simulation model that can dynamically generate realistically saturated interferograms from clean counterparts. This physics-based model allows training neural networks for artifact removal solely on synthesized image pairs. Secondly, to make the wavelength-dependency of artifacts directly accessible, we propose a multi-input, single-output (MISO) network framework. In addition to full B-scans, MISO receives images reconstructed from various spectral sub-windows. Our experiments confirm successful generalization of networks trained on simulated training data to real-world artifact removal in ophthalmic anterior segment imaging. This includes reflexes of various origin in diagnostic or intra-surgical imaging, such as different tissue structures or surgical instruments. Furthermore, a comparison of the proposed multi-input network to single-input baselines reveals consistent performance and reliability gains on both swept-source and spectral domain datasets.