Marion Bost

Marion Bost

Auto-generated profile, based on publicly available information

Marion Bost

University of Lyon, IFSTTAR, GERS, RRO, Lyon, France

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2017 in Rock Mechanics and Rock Engineering
Verified
Journal Article
Closed access
PDF file
HMHussein Mouzannar
Hussein Mouzannar
MBMarion Bost
Marion Bost
MLMadly Leroux
Madly Leroux
DVDidier Virely
Didier Virely

20 October 2016 in Bulletin of Engineering Geology and the Environment
Verified
Journal Article
Closed access
PDF file
MBMarion Bost
Marion Bost
APAhmad Pouya
Ahmad Pouya

1 July 2019 in International Journal of Rock Mechanics and Mining Sciences
Verified
Journal Article
Closed access
DHD.-A. Ho
D.-A. Ho
MBM. Bost
M. Bost
JRJ.-P. Rajot
J.-P. Rajot

29 November 2010 in Sensors
Verified
Journal Article
Open access
PDF file
MPMonica Proto
Monica Proto
MBMassimo Bavusi
Massimo Bavusi
RBRomeo Bernini
Romeo Bernini
LBLorenzo Bigagli
Lorenzo Bigagli
MBMarie Bost
Marie Bost
FTFédrèric Taillade
Fédrèric Taillade
The ISTIMES project, funded by the European Commission in the frame of a joint Call “ICT and Security” of the Seventh Framework Programme, is presented and preliminary research results are discussed. The main objective of the ISTIMES project is to design, assess and promote an Information and Communication Technologies (ICT)-based system, exploiting distributed and local sensors, for non-destructive electromagnetic monitoring of critical transport infrastructures. The integration of electromagnetic technologies with new ICT information and telecommunications systems enables remotely controlled monitoring and surveillance and real time data imaging of the critical transport infrastructures. The project exploits different non-invasive imaging technologies based on electromagnetic sensing (optic fiber sensors, Synthetic Aperture Radar satellite platform based, hyperspectral spectroscopy, Infrared thermography, Ground Penetrating Radar-, low-frequency geophysical techniques, Ground based systems for displacement monitoring). In this paper, we show the preliminary results arising from the GPR and infrared thermographic measurements carried out on the Musmeci bridge in Potenza, located in a highly seismic area of the Apennine chain (Southern Italy) and representing one of the test beds of the project.

3 September 2017 in European Journal of Environmental and Civil Engineering
Verified
Journal Article
Closed access
TBTan-Trung Bui
Tan-Trung Bui
ALAli Limam
Ali Limam
WNWendpanga-Serge-Auguste Nana
Wendpanga-Serge-Auguste Nana
EFEmmanuel Ferrier
Emmanuel Ferrier
MBMarion Bost
Marion Bost
QBQuoc-Bao Bui
Quoc-Bao Bui
The shear design of concrete slabs is still an unsolved problem. The following study presents experimental and numerical investigations on the shear behaviour of reinforced concrete slabs (without shear reinforcement) under concentrated loads. The small thick slabs of 10 cm were tested in this study. Experimental tests were conducted to quantify the shear strength and the associated failure modes. The influence of several variables was addressed such as the influence of boundary conditions, four supported side slabs instead of two supported side slabs, the influence of loading plate length. A series of eight tests on six slabs were presented. The experiments are firstly used to evaluate the pertinence of Eurocode 2 and Model Code 2010 formulations using the levels of approximation LoA I and LoA II for the shear design of reinforced concrete slabs without shear reinforcement in comparison with the French approach, and secondly validated numerical modelling using the non-linear finite element method. The proposed numerical model showed good agreement with the experimental results in terms of slab behaviour.

30 November 2018 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
WNW. S. A. Nana
W. S. A. Nana
TBTan-Trung Bui
Tan-Trung Bui
MBM. Bost
M. Bost
ALA. Limam
A. Limam
For reinforced concrete structures, as beams, slabs or walls, failure under bending is well known and its description and design is relatively internationally agreed. However for the shear failure phenomenon, there is not yet a common agreement at the international level, no consensus is reached on the subject at this time. Many parameters are involved in the shear resistance mechanism and many phenomena coexist. The shear force transfer mechanisms are sometimes complex and difficult to discern. By analyzing the different shear design codes, some shear parameters are taken into account and ignored by others, which makes that a shear effect may be omitted. In addition, different ways are adopted to take into account the different shear parameters. The main purpose of this study is to help the engineering by presenting a comparative study of all the main analytical models for the determination of shear capacity: The EN 1992-1-1:2005 standard (EC2) (CEN, 2005), French National Annex (FD P 18-717, 2013), ACI 318-14 (ACI Committee 318, 2014), fib Model Code 2010 (Fib Model Code 2010, 2012) using level of approximation LoA I and LoA II and (CSA Committee A23.3, 2004) both Modified Compression Field Theory (MCFT) based models, and finally the Critical Shear Crack Theory (CSCT) which is the basis of the Swiss standard SIA 262 (SIA 262, 2003) are all examined. The results obtained are discussed regarding their agreement with eighteen shear experimental results on thick slabs (30 cm, 35 cm, and 40 cm) and thin slabs (10 cm) without shear reinforcement.