14 October 2021 in Engineering Research Express
4 September 2017 in Chemical Communications
Through a simple chemical activation of biomolecules present in the outer structures of microbial cells, microorganisms can be rapidly isolated on gold-coated surfaces in a microfluidic device with over 99% capture efficiency.
20 November 2012 in Biopolymers and Cell
Aim. To determine an influence of serum components on the L-arginine biosensor sensitivity and to formulate practical recommendations for its reliable analysis. Methods. The L-arginine biosensor comprised arginase and urease co-immobilized by cross-linking. Results. The biosensor specificity was investigated based on a series of representative studies (namely, through urea determination in the serum; inhibitory effect studies of mercury ions; high temperature treatment of sensors; studying the biosensor sensitivity to the serum treated by enzymes, and selectivity studies). It was found that the response of the biosensor to the serum injections was determined by high sensitivity of the L-arginine biosensor toward not only to L-arginine but also toward two other basic amino acids (L-lysine and L-histidine). Conclusions. A detailed procedure of optimization of the conductometric biosensor for L-arginine determination in blood serum has been proposed
21 October 2021 in Tekhnichna Elektrodynamika
The differential method of conductometric measurements does not fully solve the problem of the influence of changes in the background electrical conductivity of the working buffer solutions on the results of conversion of the biosensor responses. The variation in the background electrical conductivity of the buffer solution upon addition of the highly conductive analyte acts as a common mode interference and causes the additive error. Here we present a new measurement method and structure of the device for quantification of the analytes that provide a significant decrease in the measurement error associated with a change in the background electrical conductivity caused by the introduction of the analyte to the working solution prior to the generation of the informative signal. A block diagram of the device and a vector model of the balancing process of its measuring circuit are presented. The advantages of the developed method and biosensor analyzer for application within the possible changes of the transducer parameters and measurement conditions are demonstrated. References 28, figures 4.
25 May 2022 in Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
A method for measuring local changes in the electrical conductivity of solutions using differential conductometric sensors is considered. The method makes it possible to significantly reduce the measurement error due to changes in the background electrical conductivity of the measuring medium when applying the test substance with non-identical parameters of equivalent electrical circuits of the sensor components. The bridge measuring circuit is brought to a quasi-balanced state, while the voltages in the sections of the working solution of the working and reference transducers of the sensor coincide in phase with each other, and their values are proportional to the conductivity of these sections. At the same time, changes in the background electrical conductivity of the solution do not lead to a change in the imbalance signal of the bridge circuit, which allows measuring the informative local change in the electrical conductivity of the working transducer with high sensitivity. The method can be used for highly sensitive and accurate quantification of solutions of electrically conductive substances in technological processes in the energy, chemical, and food industries, in the latest technologies, in particular in biosensor analyzers. The research results of the experimental sample of the conductometric analyzer are given. Ref. 9, table. Розглянуто спосіб вимірювання локальних змін електропровідності розчинів з використанням диференційних кондуктометричних сенсорів. Спосіб дає можливість за неідентичних параметрів еквівалентних електричних схем компонентів сенсора суттєво знизити похибку вимірювань, зумовлену змінами фонової електропровідності вимірювального середовища під час внесення досліджуваної речовини. Мостове вимірювальне коло приводиться в стан квазірівноваги, водночас напруги на ділянках робочого розчину робочого і референсного перетворювачів сенсора збігаються за фазою між собою, а їхні значення пропорційні значенням електропровідності цих ділянок. Водночас зміни фонової електропровідності розчину не призводять до зміни сигналу нерівноваги мостового кола, що дає змогу вимірювати інформативну локальну зміну електропровідності робочого перетворювача з високою чутливістю. Спосіб може бути використаний для високочутливого і точного визначення кількісного складу розчинів електропровідних речовин у технологічних процесах в енергетиці, хімічній та харчовій промисловості, в новітніх технологіях, зокрема в біосенсорних аналізаторах. Наведено результати комп’ютерного моделювання розробленого способу. Бібл. 9, таблиця.