Yi Deng

Yi Deng

Auto-generated profile, based on publicly available information

Yi Deng

Graduate School of Pure and Applied Sciences, University of Tsukuba

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2024 in ACS Omega
Verified
Journal Article
Open access
YSYusuke Shirato
Yusuke Shirato
AHAn-Ju Hsueh
An-Ju Hsueh
NMNurul Asyikeen Ab Mutalib
Nurul Asyikeen Ab Mutalib
YDYi Deng
Yi Deng
RSRyohei Suematsu
Ryohei Suematsu
HSHiroaki Suzuki
Hiroaki Suzuki
Various miniature Clark-type oxygen electrodes (COEs), which are typically used to measure dissolved oxygen (DO) concentration in cellular respiration, have been developed since the 1980s. Arrays with individually addressable electrodes that constitute the sensor were used for various applications. However, the large number of leads and contact pads required for connecting the electrodes and the external instrument complicate the electrode layout and make the operation of integrated COE arrays challenging. Here, we fabricated closed bipolar electrochemical systems comprising 6 × 8 and 4 × 4 arrays of COEs for imaging and multiplexed detection. The cathodic compartment was sealed with a hydrophobic oxygen-permeable membrane to separate the internal electrolyte solution from the sample solutions. Using the bipolar Clark-type oxygen electrode (BCOE) arrays and electrochemiluminescence (ECL), we measured the DO concentration at each cathode. The results revealed that the ECL intensity changed linearly with the DO concentration. In addition, we used ECL imaging to investigate the respiratory activity of Escherichia coli (E. coli) and Pseudomonas aeruginosa (P. aeruginosa) in suspensions with different cell densities. The ECL images showed that the ECL intensity changed noticeably with the bacterial density. The bacterial respiratory activity was then qualitatively analyzed based on the ECL images acquired successively over a time duration. Further, we measured the antibiotic efficacy of piperacillin, oxacillin, gentamicin, and cefmetazole against E. coli and P. aeruginosa using the BCOE. We found that the ECL intensity increased with the antibiotic concentration, thus indicating the suppression of the bacterial respiratory activity.

28 February 2026 in Electrochemistry
Verified
Journal Article
Open access
PDF file
YDYi Deng
Yi Deng
NMNurul Asyikeen Ab Mutalib
Nurul Asyikeen Ab Mutalib
JXJian Xiong
Jian Xiong
HSHiroaki Suzuki
Hiroaki Suzuki
STSeiya TSUJIMURA
Seiya TSUJIMURA
An electrochemical circuit containing a control unit is used to control the interfacial potential difference between the bipolar electrodes (BPEs) and the electrolyte solution in an open bipolar system. The control unit consists of a polymeric Na+ ion-selective electrode (ISE) connected to a BPE and an Ag/AgCl wire, which connects the electrolyte solution in the control unit to the main chamber via the BPEs. The BPEs contain openings with exposed platinum areas, which serve as cathodic and anodic poles and a potential-determining element. The interfacial potential difference between the potential-determining opening (PDO) and the electrolyte solution can be determined by applying Kirchhoff's second law to the closed circuit containing the PDO, ISE, and Ag/AgCl wire. In the open bipolar system, the intensity of the electrochemiluminescence signal measured for analysis varies depending on the position of the opening of the BPEs. The results suggest that the interfacial potential difference between the anodic and cathodic poles can be varied with a control unit by avoiding ionic crosstalk.

1 November 2026 in Electrochemistry
Verified
Journal Article
Open access
PDF file
JXJian Xiong
Jian Xiong
YDYi Deng
Yi Deng
HSHiroaki Suzuki
Hiroaki Suzuki
STSeiya TSUJIMURA
Seiya TSUJIMURA
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.