Adrien Rapeaux

Adrien Rapeaux

Auto-generated profile, based on publicly available information

Adrien Rapeaux

Imperial College London Faculty of Engineering, Imperial College London, London, SW7 2AZ, United Kingdom of Great Britain and Northern Ireland

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Current Opinion in Biotechnology
Verified
Journal Article
Open access
ARAdrien B Rapeaux
Adrien B Rapeaux
TCTimothy Constandinou
Timothy Constandinou
Implantable brain machine interfaces (BMIs) are now on a trajectory to go mainstream, wherein what was once considered last resort will progressively become elective at earlier stages in disease treatment. First-in-human successes have demonstrated the ability to decode highly dexterous motor skills such as handwriting, and speech from human cortical activity. These have been used for cursor and prosthesis control, direct-to-text communication and speech synthesis. Along with these breakthrough studies, technology advancements have enabled the observation of more channels of neural activity through new concepts for centralised/distributed implant architectures. This is complemented by research in flexible substrates, packaging, surgical workflows and data processing. New regulatory guidance and funding has galvanised the field. This culmination of resource, efforts and capability is now attracting significant investment for BMI commercialisation. This paper reviews recent developments and describes the paradigm shift in BMI development that is leading to new innovations, insights and BMI translation.

3 November 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
YLYan Liu
Yan Liu
SLSong Luan
Song Luan
IWIan Williams
Ian Williams
ARAdrien Rapeaux
Adrien Rapeaux
TCTimothy Constandinou
Timothy Constandinou
Modern microtechnology is enabling the channel count of neural recording integrated circuits to scale exponentially. However, the raw data bandwidth of these systems is increasing proportionately, presenting major challenges in terms of power consumption and data transmission (especially for wireless systems). This paper presents a system that exploits the sparse nature of neural signals to address these challenges and provides a reconfigurable low-bandwidth event-driven output. Specifically, we present a novel 64-channel low-noise (2.1 $\mu$V$_{\text{rms}}$), low-power (23 $\mu$W per analogue channel) neural recording system-on-chip (SoC). This features individually configurable channels, 10-bit analogue-to-digital conversion, digital filtering, spike detection, and an event-driven output. Each channel’s gain, bandwidth, and sampling rate settings can be independently configured to extract local field potentials at a low data-rate and/or action potentials (APs) at a higher data rate. The sampled data are streamed through an SRAM buffer that supports additional on-chip processing such as digital filtering and spike detection. Real-time spike detection can achieve $\sim$2 orders of magnitude data reduction, by using a dual polarity simple threshold to enable an event driven output for neural spikes (16-sample window). The SoC additionally features a latency-encoded asynchronous output that is critical if used as part of a closed-loop system. This has been specifically developed to complement a separate on-node spike sorting coprocessor to provide a real-time (low latency) output. The system has been implemented in a commercially available 0.35-$\mu$m CMOS technology occupying a silicon area of 19.1 mm$^2$ (0.3 mm$^2$ gross per channel), demonstrating a low-power and efficient architecture that could be further optimized by aggressive technology and supply voltage scaling.

3 May 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
Charalambos HadjipanayiCharalambos Hadjipanayi
Charalambos Hadjipanayi
MYMaowen Yin
Maowen Yin
ABAlan Bannon
Alan Bannon
ARAdrien Rapeaux
Adrien Rapeaux
MBMatthew Banger
Matthew Banger
TCTimothy Constandinou
Timothy Constandinou
Objective: In recent years, radar technology has been extensively utilized in contactless human behavior monitoring systems. The unique capabilities of ultra-wideband (UWB) radars compared to conventional radar technologies, due to time-of-flight measurements, present new untapped opportunities for in-depth monitoring of human movement during overground locomotion. This study aims to investigate the deployability of UWB radars in accurately capturing the gait patterns of healthy individuals with no known walking impairments. Methods: A novel algorithm was developed that can extract ten clinical spatiotemporal gait features using the Doppler information captured from three monostatic UWB radar sensors during a 6-meter walking task. Key gait events are detected from lower-extremity movements based on the joint range-Doppler-time representation of recorded radar data. The estimated gait parameters were validated against a gold-standard optical motion tracking system using 12 healthy volunteers. Results: On average, nine gait parameters can be consistently estimated with 90-98% accuracy, while capturing 94.5% of participants' gait variability and 90.8% of inter-limb symmetry. Correlation and Bland-Altman analysis revealed a strong correlation between radar-based parameters and the ground-truth values, with average discrepancies consistently close to 0. Conclusion: Results prove that radar sensing can provide accurate biomarkers to supplement clinical human gait analysis, with quality similar to gold standard assessment. Significance: Radars can potentially allow a transition from expensive and cumbersome lab-based gait analysis tools toward a completely unobtrusive and affordable solution for in-home deployment, enabling continuous long-term monitoring of individuals for research and healthcare applications.

10 September 2020 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
IWIan Williams
Ian Williams
EBEmma Brunton
Emma Brunton
ARAdrien Rapeaux
Adrien Rapeaux
YLYan Liu
Yan Liu
SLSong Luan
Song Luan
TCTimothy Constandinou
Timothy Constandinou
Chronic in-vivo neurophysiology experiments require highly miniaturized, remotely powered multi-channel neural interfaces which are currently lacking in power or flexibility post implantation. To resolve this problem we present the SenseBack system, a post-implantation reprogrammable wireless 32-channel bidirectional neural interfacing device that can enable chronic peripheral electrophysiology experiments in freely behaving small animals. The large number of channels for a peripheral neural interface, coupled with fully implantable hardware and complete software flexibility enable complex in-vivo studies where the system can adapt to evolving study needs as they arise. In complementary \textit{ex-vivo} and \textit{in-vivo} preparations, we demonstrate that this system can record neural signals and perform high-voltage, bipolar stimulation on any channel. In addition, we demonstrate transcutaneous power delivery and Bluetooth 5 data communication with a PC. The SenseBack system is capable of stimulation on any channel with 20 V of compliance and up to 315 A of current, and highly configurable recording with per-channel adjustable gain and filtering with 8 sets of 10-bit ADCs to sample data at 20 kHz for each channel. To our knowledge this is the first such implantable research platform offering this level of performance and flexibility post-implantation (including complete reprogramming even after encapsulation) for small animal electrophysiology. Here we present initial acute trials, demonstrations and progress towards a system that we expect to enable a wide range of electrophysiology experiments in freely behaving animals.

6 March 2025 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MYMaowen Yin
Maowen Yin
Charalambos HadjipanayiCharalambos Hadjipanayi
Charalambos Hadjipanayi
KRKiran K G Ravindran
Kiran K G Ravindran
ABAlan Bannon
Alan Bannon
ARAdrien Rapeaux
Adrien Rapeaux
TCTimothy Constandinou
Timothy Constandinou
Objective: Ultra-wideband (UWB) radar technology has emerged as a promising alternative for creating portable and cost-effective in-home monitoring devices. Although there exists good evidence supporting its effectiveness in sleep monitoring, previous studies predominantly focus on younger, healthy participants. This research evaluates the applicability of commercial impulse UWB radar for sleep monitoring in older people and people with neurodegenerative disorders (NDDs). Methods: 47 older people (mean age: 71.2 $\pm$ 6.5, 18 with prodromal or mild Alzheimer's disease) participated in our overnight sleep trial with polysomnography (PSG) and UWB radar monitoring. Data processing based on multivariate empirical mode decomposition (MEMD) was employed to reconstruct cardiopulmonary activity and limb movements from radar signals. 29 features were extracted from the radar signals, and sleep stages were classified using a sequence-to-sequence neural network. Additionally, a cross-entropy-based approach was used to quantify uncertainties in the radar classification model and provide confidence in the classification. Results: The UWB radar system demonstrated high accuracy in detecting body movements, reconstructing respiratory patterns, and monitoring heart rate. For sleep stage classification, the results showed a Kappa coefficient of 0.63 and an average accuracy of 74.4% across wake, REM sleep, light sleep (N1 + N2), and deep sleep (N3) categories. Conclusion: The proposed method reliably monitors physiological changes during sleep, which suggests its potential as a cost-effective alternative to traditional sleep monitoring devices. Significance: The findings underscore the viability of UWB radar as a nonintrusive, forward-looking sleep assessment tool that could significantly benefit care for older people and people with neurodegenerative disorders.

19 May 2020 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
ARAdrien Rapeaux
Adrien Rapeaux
TCTimothy Constandinou
Timothy Constandinou
Objective: This paper describes the design, testing and use of a novel multichannel block-capable stimulator for acute neurophysiology experiments to study highly selective neural interfacing techniques. This paper demonstrates the stimulator's ability to excite and inhibit nerve activity in the rat sciatic nerve model concurrently using monophasic and biphasic nerve stimulation as well as high-frequency alternating current (HFAC). Approach: The proposed stimulator uses a Howland Current Pump circuit as the main analogue stimulator element. 4 current output channels with a common return path were implemented on printed circuit board using Commercial Off-The-Shelf components. Programmable operation is carried out by an ARM Cortex-M4 Microcontroller on the Freescale freedom development platform (K64F). Main Results: This stimulator design achieves +-10 mA of output current with +-15 V of compliance and less than 6 uA of resolution using a quad-channel 12-bit external DAC, for four independently driven channels. This allows the stimulator to carry out both excitatory and inhibitory (HFAC block) stimulation. DC Output impedance is above 1 Mohm. Overall cost for materials i.e. PCB boards and electronic components is less than USD 450 or GBP 350 and device size is approximately 9 cm x 6 cm x 5 cm. Significance: Experimental neurophysiology often requires significant investment in bulky equipment for specific stimulation requirements, especially when using HFAC block. Different stimulators have limited means of communicating with each other, making protocols more complicated. This device provides an effective solution for multi-channel stimulation and block of nerves, enabling studies on selective neural interfacing in acute scenarios with an affordable, portable and space-saving design for the laboratory. The stimulator can be further upgraded with additional modules to extend functionality while maintaining straightforward programming and integration of functions with one controller. Additionally, all source files including all code and PCB design files are freely available to the community to use and further develop.