Tianqi Zhu

Tianqi Zhu

Auto-generated profile, based on publicly available information

Tianqi Zhu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2025 in Materials & Design
Verified
Journal Article
Open access
TZTianqi Zhu
Tianqi Zhu
YXYingchun Xie
Yingchun Xie
BSBo Song
Bo Song
CCChaoyue Chen
Chaoyue Chen
RZRuixin Zhao
Ruixin Zhao
Shuo YinShuo Yin
Shuo Yin

25 September 2022 in Materials Science and Engineering: A
Verified
Journal Article
Closed access
TZTianqi Zhu
Tianqi Zhu
HLHongmei Li
Hongmei Li
NTNaoki Takata
Naoki Takata
MKMakoto Kobashi
Makoto Kobashi
MYMasataka Yoshino
Masataka Yoshino

27 October 2025 in Acta Materialia
Verified
Journal Article
Open access
MLMarcus Lorentzon
Marcus Lorentzon
Naoki TakataNaoki Takata
Naoki Takata
DDDiederik Depla
Diederik Depla
TZTianqi Zhu
Tianqi Zhu
GGGrzegorz Greczynski
Grzegorz Greczynski
NGNaureen Ghafoor
Naureen Ghafoor

24 July 2026 in Scripta Materialia
Verified
Journal Article
Open access
TZTianqi Zhu
Tianqi Zhu
LDLeo Devlin
Leo Devlin
WSWeiming Su
Weiming Su
YCYan Chen
Yan Chen
PYPengfei Yu
Pengfei Yu
Shuo YinShuo Yin
Shuo Yin

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
TZTianqi Zhu
Tianqi Zhu
HLHongmei Li
Hongmei Li
NTNaoki Takata
Naoki Takata
MKMakoto Kobashi
Makoto Kobashi
MYMasataka Yoshino
Masataka Yoshino
The aim of the present study was to identify the effect of solute Ni element on the plastic deformation and its thermal activation process of 18Cr ferritic stainless steels. Single-crystal micropillars with different diameters of approximately 2 and 5 μm were fabricated on the surface of Fe-18%Cr-Ni alloy sheets containing different contents of Ni (0–2 mass%). Compression tests were performed on the micropillars at different initial strain rates to investigate the strain rate sensitivity ( m ) of stress for the slip initiation and the specimen-size dependence of the m value. In micropillars with a small diameter of 2 μm, the Fe-18Cr binary alloy specimen exhibited a relatively higher strain-rate sensitivity of initial slip stress ( m = 0.12), whereas m was reduced to 0.01 by adding 2% Ni. The same trend was observed in micropillars with a larger size of approximately 5 μm. The experimental results were utilized to evaluate the activation volume of plastic deformation. The activation volumes of the Fe-18%Cr alloy and alloy containing 1% Ni followed the specimen-size dependence trend of activation volume in bcc metals; however, the alloy containing 2% Ni exhibited larger activation volumes, suggesting a different thermal activation process presumably due to the significant interaction that occurred between dislocations and solute Ni atoms in bcc solid-solutions.