16 October 2014 in IEEE Transactions on Applied Superconductivity
A high-resolution 1.3-GHz/54-mm low-temperature superconducting/high-temperature superconducting (HTS) nuclear magnetic resonance magnet (1.3 G) is currently in the final stage at the Massachusetts Institute of Technology Francis Bitter Magnet Laboratory. Its key component is a three-coil (Coils 1-3) 800-MHz HTS insert comprising 96 no-insulation (NI) double-pancake coils, each wound with a 6-mm-wide GdBCO tape. In this paper, after describing the overall 1.3-G system, we present innovative design features incorporated in 1.3 G: 1) an NI winding technique applied to Coils 1-3 and its adverse effect in the form of charging time delay; 2) persistent-mode HTS shims; 3) a “shaking” magnet; and 4) preliminary results of Coil 1 operated at 4.2 K.
23 August 2019 in Superconductor Science and Technology
The nonuniform superconducting current distribution in a REBCO coated conductor, including a varying-field-induced screening current, is responsible for a significant magnetization effect that not only degrades the field quality of REBCO magnets, but introduces risks of overstressing the conductor. This paper presents our experimental and simulation studies on the screening current effect on an 800 MHz (18.8 T) REBCO insert (H800) that together with a 500 MHz LTS nuclear magnetic resonance (NMR) magnet (L500) constitutes the MIT 1.3 GHz LTS/HTS NMR magnet (1.3 G). To develop our simulation model, which was subsequently validated by a good agreement between simulation and experiment, we chose H800, Coil 1 of the 3-coil assembly operated alone and the entire H800, for the sources of experimental data, specifically their remnant fields after current discharge and diminished axial fields during operation. Armed with this valid model, we examined in detail the negative effects of screening current on H800, an important 1.3 G component. Our simulation indicates that the screening current, nonuniformly distributed in the REBCO conductor, not only deteriorates H800 field, both strength and homogeneity, thus that of 1.3 G, but may overstress the REBCO conductor.
25 February 2019 in IEEE Transactions on Applied Superconductivity
We present assembly and test results of a 3-nested-coil 800-MHz (18.8 T) REBCO insert (H800) for the MIT 1.3 GHz LTS/HTS NMR magnet currently under completion. Each of the three H800 coils is a stack of no-insulation (NI) REBCO double-pancake coils (DPs). The innermost 8.7-T Coil 1 (26 DPs) was completed by mid-2016; the middle 5.6-T Coil 2 (32 DPs) was completed in mid-2017; while the outermost 4.5-T Coil 3 (38 DPs) was completed in early 2018. Coils 1, 2, and 3 were assembled together in early 2018 as a 3-nested-coil, the H800, and tested, first in liquid nitrogen to a power supply current of 20 A, followed by testing in liquid helium to a power supply current of 251.3 A, the H800's design operating current. After roughly five minutes settling time at 251.3 A, the H800 quenched. In this paper, we examine probable sources of quench initiation and simulate ensuing quench behavior. Remedial efforts to minimize the tendency toward quenching in the H800 are presented and discussed.
17 March 2017 in Superconductor Science and Technology
In this article I present our experience at the Magnet Technology Division of the MIT Francis Bitter Magnet Laboratory on liquid-helium (LHe)-free, persistent-mode MgB 2 MRI magnets. Before reporting on our MgB 2 magnets, I first summarize the basic work that we began in the late 1990s to develop LHe-free, high-temperature superconductor (HTS) magnets cooled in solid cryogen—I begin by discussing the enabling feature, particularly of solid nitrogen (SN2), for adiabatic HTS magnets. The next topic is our first LHe-free, SN2–HTS magnet, for which we chose Bi2223 because in the late 1990s Bi2223 was the only HTS available to build an HTS magnet. I then move on to two MgB 2 magnets, I and II, developed after discovery of MgB 2 in 2000. The SN2–MgB 2 Magnet II—0.5 T/240 mm, SN2-cooled, and operated in persistent mode—was completed in January 2016. The final major topic in this article is a tabletop LHe-free, persistent-mode 1.5 T/70 mm SN2–MgB 2 ‘finger’ MRI magnet for osteoporosis screening—we expect to begin this project in 2017. Before concluding this article, I present my current view on challenges and prospects for MgB 2 MRI magnets.
18 February 2020 in IEEE Transactions on Applied Superconductivity
Screening currents in REBCO conductors, induced by time-varying magnetic fields, not only affect the field quality of HTS coils but also cause strain gradients along REBCO tape width that may overstress REBCO conductors used in NMR and other high-field magnets. In this paper, we present results of an experimental and analytical study on screening-current-induced strain gradients, performed with small REBCO pancake coils. Because we believe that screening current effect is reduced in multifilament conductor, we have studied 2 test coils, φ150 mm, one wound with monofilament and the other with 3-striate/4-filament REBCO tapes. A 5-T/ 300-mm room-temperature bore magnet was used not only to excite a strong screening current but also apply the nonuniform Lorentz force to each coil at 4.2 K. Our experiment and analysis have quantitatively demonstrated that we can effectively suppress the screening-current effect on strain gradient, not surprisingly, by using striated multifilament REBCO conductor.
1 December 2016 in IEEE Transactions on Applied Superconductivity
A 1.3-GHz/54-mm LTS/HTS NMR magnet, assembled with a three-coil (Coils 1-3) 800-MHz HTS insert in a 500-MHz LTS NMR magnet, is under construction. The innermost HTS insert Coil 1 has a stack of 26 no-insulation (NI) double pancake (DP) coils wound of 6-mm-wide and 75-μm-thick REBCO tapes. In order to keep the hoop strains on REBCO tape <;0.6% at an operating current I op of 250 A and in a field of 30.5 T, we overbanded each pancake in Coil 1 with a 6-mm-wide, 76-μm-thick 304 stainless steel strip: 7-mm-thick radial build for the central 18 pancakes, while 6-mm-thick for the outer 2 × 17 pancakes. In this paper, Coil 1 was successfully tested at 77 K and 4.2 K. In the 77-K test, the measured critical current was 35.7 A, determined by an E-field criterion of 0.1 μV/cm. The center field magnet constant decreased from 34.2 to 29.3 mT/A, when I op increased from 5 to 40 A. The field distribution at different I op along the z-axis was measured. The residual field distributions discharged from 10 and 20 A were recorded. In the 4.2-K test, Coil 1 successfully generated a central field of 8.78 T at 255 A. The magnet constant is 34.4 mT/A, which is same as our designed value. The field homogeneity at the coil center within a ±15-mm region is around 1700 ppm. This large error field must be reduced before field shimming is applied.