Woo Seung Lee

Woo Seung Lee

Auto-generated profile, based on publicly available information

Woo Seung Lee

Korea Basic Science Institute, Cheongju-si, South Korea

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YLYi Li
Yi Li
DPDongkeun Park
Dongkeun Park
WLWooseung Lee
Wooseung Lee
YCYoonhyuck Choi
Yoonhyuck Choi
HTHiromi Tanaka
Hiromi Tanaka
YIYukikazu Iwasa
Yukikazu Iwasa
Screening currents in REBCO conductors, induced by time-varying magnetic fields, not only affect the field quality of HTS coils but also cause strain gradients along REBCO tape width that may overstress REBCO conductors used in NMR and other high-field magnets. In this paper, we present results of an experimental and analytical study on screening-current-induced strain gradients, performed with small REBCO pancake coils. Because we believe that screening current effect is reduced in multifilament conductor, we have studied 2 test coils, φ150 mm, one wound with monofilament and the other with 3-striate/4-filament REBCO tapes. A 5-T/ 300-mm room-temperature bore magnet was used not only to excite a strong screening current but also apply the nonuniform Lorentz force to each coil at 4.2 K. Our experiment and analysis have quantitatively demonstrated that we can effectively suppress the screening-current effect on strain gradient, not surprisingly, by using striated multifilament REBCO conductor.

4 March 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
DPDongkeun Park
Dongkeun Park
JBJuan Bascunan
Juan Bascunan
YLYi Li
Yi Li
WLWooseung Lee
Wooseung Lee
YCYoonhyuck Choi
Yoonhyuck Choi
YIYukikazu Iwasa
Yukikazu Iwasa
We present a design overview of the MIT 1.3-GHz LTS/HTS NMR magnet (1.3G) with a newly designed 835-MHz REBCO insert (H835) as a replacement for the 800-MHz REBCO insert (H800) that was damaged when it quenched during operation in 2018. The new H835 is designed to contribute 19.6 T in a background field of 10.93 T by an LTS NMR magnet that normally rated at 11.74 T (500 MHz): combined, 1.3G generates a total field of 30.53 T corresponding to a proton resonance frequency of 1.3 GHz. H835 is designed to operate stably while meeting 1.3G design constraints. We have also designed H835 to protect it from permanent damage in an improbable event like a quench. Key design features are: 1) a single-coil formation, composed of 38 stacked metal-co-wound no-insulation and 2 stacked no-insulation double-pancake coils, all with mechanically improved cross-over sections; 2) enhanced thermal stability; and 3) reduced current margin with a detect-and-heat method. This paper includes: 1) electromagnetic and mechanical design of H835; 2) cryogenics overview; 3) quench protection strategy; and 3) discussion on the next steps to successfully complete 1.3G.

31 August 2022 in Superconductor Science and Technology
Verified
Journal Article
Closed access
WLWooseung Lee
Wooseung Lee
DPDongkeun Park
Dongkeun Park
JBJuan Bascuñán
Juan Bascuñán
YIYukikazu Iwasa
Yukikazu Iwasa
A compact benchtop high-field REBCO nuclear magnetic resonance is one of the most promising high-temperature superconductor applications. An all-REBCO, conduction-cooled magnet is a very attractive design option for demonstrating the unique potential of REBCO for forefront magnets. In this research, we have successfully constructed and tested a prototype all-REBCO, conduction-cooled, 23.5 T magnet operating at 10 K. We have applied the concept of an extreme no-insulation winding technique, coupled with a solder-shunting procedure to improve magnet performance. We have also used a temperature-controlled charging sequence to reduce the screening current. The magnet was energized to 23.6 T at 14 K; it was further operated to 25 T at 10 K for nearly 60 h.

23 March 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
DPDongkeun Park
Dongkeun Park
WLWooseung Lee
Wooseung Lee
JBJuan Bascunan
Juan Bascunan
HKHo Min Kim
Ho Min Kim
YIYukikazu Iwasa
Yukikazu Iwasa
We present the operation result of a cryogen-free 23.5 T/ϕ12.5 mm-cold-bore magnet prototype composed of a stack of 12 no-insulation (NI) REBCO single pancake coils—ten middle coils of 6-mm wide and two end coils of 8-mm wide tape—forming 6 double pancake (DP) coils with inner joints. Each coil was wound with the tape having only 1-μm-thick copper layer on each side to overcome the conductor thickness uniformity issue and enhance the mechanical strength within the winding, and then, additional electrical shunting by thin layers of solder was applied on the top and bottom surfaces of each DP coil for effective cooling and quench protection—called extreme-NI winding technique. With this small prototype magnet towards a benchtop 1-GHz NMR, we validate our coil design that include conductor performance, screening-current-induced field and stresses, and conduction-cooling cryogenics. Included in the paper are: 1) conductor issues and our counterproposal in winding; 2) screening-current reduction method; 3) design and manufacture summary of the magnet; and 4) operating test results of the magnet up to 25 Tesla.

7 November 2022 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
FDFangliang Dong
Fangliang Dong
DPDongkeun Park
Dongkeun Park
WLWooseung Lee
Wooseung Lee
LHLuning Hao
Luning Hao
ZHZhen Huang
Zhen Huang
YIYukikazu Iwasa
Yukikazu Iwasa
Here, we present experimental and analytical results of a preventive approach applied to a fault-mode phenomenon caused by electrodes or power-source failure in a no-insulation (NI) high-temperature superconducting REBa2Cu3O7−x (REBCO, RE = rare earth) magnet. It is generally agreed that the NI magnets, at least those of laboratory scale, are self-protected from overheating and, therefore, from quenching, chiefly because of turn-to-turn current bypassing unique to NI. However, these NI magnets do experience unexpected quenches, e.g., when the current through the magnet suddenly drops due to the aforementioned fault-mode phenomenon. Here, we report this phenomenon of a sudden-discharging-triggered quench of an NI REBCO coil, conduction-cooled, and operated at 4.2 K. We also present our preventive approach for this phenomenon that relies on an appropriately designed resistor shunted across the coil terminals. With this shunt resistor, a quench was prevented by suppressing the quench initiating turn-to-turn heat and induced overcurrent within the NI winding, and the coil current decayed safely.

14 February 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YCYoon Do Chung
Yoon Do Chung
EPEun Young Park
Eun Young Park
WLWoo Seung Lee
Woo Seung Lee
JLJe Yull Lee
Je Yull Lee
Our research team has been developed wireless power charging (WPC) system for electric vehicle (EV) using superconducting and normal conducting resonance coils in order to improve the transfer efficiency and stability. In the practical approach, when the EV, which is installed outside, is wirelessly charged without moving. The antenna (Tx) coil is disclosed by rain or snow and so on. From this reason, the transfer characteristics surrounded aqua circumstance i.e. fresh water or salt water, should be evaluated to commercialize In addition, the high voltage wireless power charging system generates strong electromagnetic fields (EMFs) around Tx an receiver (Rx) coils. As the human safety with respect to EMFs is an important measure, it is required to identify the condition under which human exposure complies with the safety regulations. Thus, in this paper, as a fundamental approach, the spatial spots of current around Tx and Rx coils were measured. As well as, the transfer efficiencies of WPC unit under different aqua circumstances of Tx and Rx coil were measured with RF generator power of 150 W, 370 kHz.