Chen Chen

Chen Chen

Auto-generated profile, based on publicly available information

Chen Chen

Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences 4 , Suzhou 215123

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2024 in Nanophotonics
Verified
Journal Article
Open access
PDF file
BLBaiying Lyu
Baiying Lyu
CCChen Chen
Chen Chen
JWJian Wang
Jian Wang
CLChang Li
Chang Li
WZWei Zhang
Wei Zhang
DWDongmin Wu
Dongmin Wu
Structured light projection provides a promising approach to achieving fast and non‐contact three‐dimensional (3D) imaging. The resolution is a crucial index that represents security and accuracy in applications such as face recognition and robot vision. It depends on the density of dots in the projection. However, further improving the density of dots in the current system must be at the cost of speed or volume. Here, an all‐dielectric ultra‐thin metasurface is designed and fabricated to project a multi‐wavelength dot array. The density of dots is improved because projected dots with different wavelengths fill the gaps with each other. The experimental results demonstrate that the multi‐wavelength projection improves the resolution of 3D imaging. Furthermore, the multi‐wavelength system is beneficial to measuring a surface with varying colors. The approach has the potential to achieve a new generation of high‐resolution systems for tiny fluctuations and colorful 3D imaging in dark environments.

7 August 2023 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
MJMinwei Jiang
Minwei Jiang
HZhao zhai
hao zhai
CJChunyu Jiang
Chunyu Jiang
JWJian Wang
Jian Wang
CCChen Chen
Chen Chen
PJPeng Jin
Peng Jin
Accurate characterization of atomic vapor cells is crucial for enhancing the sensitivity of miniature atomic magnetometers. In this study, a fast and efficient approach is developed to characterize relaxation properties of the inner surface of the 87Rb micro-electro-mechanical systems (MEMS) vapor cell. Based on the zero-field level crossing effect, the transverse relaxation rate was experimentally determined, and the depolarization coefficient of 0.097 for atom-wall collisions in the 87Rb MEMS vapor cell was obtained. The experiments demonstrated that the alkali-wall collision relaxation gradually dominates the depolarization of the 87Rb ensemble as the radius of the vapor cell decreases. This research provides a quantitative method to evaluate the effectiveness of the MEMS vapor cell anti-relaxation coatings and offers the design inspiration for MEMS atomic vapor cells from the perspective of relaxation characterization. It is beneficial for the development of weak magnetic field detections such as biomagnetism detection in ambient environments.

29 August 2024 in Advanced Optical Materials
Verified
Journal Article
Closed access
CCChen Chen
Chen Chen
CLChang Li
Chang Li
BLBaiying Lv
Baiying Lv
JHJie Huang
Jie Huang
BZBaoshun Zhang
Baoshun Zhang
PJPeng Jin
Peng Jin

22 June 2024 in Laser & Photonics Reviews
Verified
Journal Article
Closed access
HQHaotong Qi
Haotong Qi
JHJianyang Hu
Jianyang Hu
CLChang Li
Chang Li
XZXuyao Zhang
Xuyao Zhang
CCChen Chen
Chen Chen
PJPeng Jin
Peng Jin

4 August 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
QZQi Zhang
Qi Zhang
JWJian Wang
Jian Wang
CJChunyu Jiang
Chunyu Jiang
CCChen Chen
Chen Chen
JWJingjing Wang
Jingjing Wang
YWYiqun Wang
Yiqun Wang
We describe a magnetically silent gradiometer based on the 87Rb micro-electro-mechanical systems vapor cell with an internal volume of 0.1 cm3. The gradiometer measures the magnetic field by probing the free induction-decay frequency in the time domain, thereby eliminating feedback loop interference and RF crosstalk. Experimental results demonstrated that a differential sensitivity of 300 fT/Hz1/2 can be realized with a millimeter-scale vapor cell, even in the geomagnetic field range, which is consistent with the theoretical differential Cramér–Rao lower bound. To characterize magnetometer noise sources, in-phase and quadrature resonance curves were recorded using a lock-in amplifier, identifying single-channel photon shot noise of approximately 180 fT/Hz1/2 as the primary limitation of the device sensitivity. The compact and array-compatible design facilitates portable quantum sensing applications in unshielded environments.

11 May 2026 in Applied Physics Letters
Verified
Journal Article
Closed access
JHJianyang Hu
Jianyang Hu
BLBin Liu
Bin Liu
CCChen Chen
Chen Chen
GLGang Liu
Gang Liu
LWLei Wang
Lei Wang
PJPeng Jin
Peng Jin
Spider webs can couple acoustic signals with maximum physical efficiency over a broad frequency range. Inspired by the acoustic flow sensing mechanism of spider webs, a fiber-optic Fabry–Pérot (F–P) hydrophone is proposed. The sensitive diaphragm of the hydrophone adopts a bionic web-like structure (BWS), where the hub diaphragm of the structure and the fiber end-face form an F–P cavity. Finite element simulation is employed to optimize the geometric structure of the BWS and a full-phase spectrum demodulation method is used to demodulate the interference spectra. The test results demonstrate that the BWS hydrophone features a bandwidth of 10–2000 Hz, a sensitivity of 52.4 nm/Pa at 100 Hz and a minimum detectable pressure of 0.44 mPa/Hz1/2, and it also exhibits favorable acoustic directivity. Furthermore, due to the hollowed-out structure of the BWS, the hydrophone is immune to hydrostatic pressure. This fiber-optic hydrophone based on the acoustic flow mechanism provides a novel strategy and solution for low-frequency, high-sensitivity underwater acoustic signal detection.