17 June 2020 in IEEE Access
We present a united coherence factor beamformer for coherent plane-wave compounding (CPWC). CPWC is capable to reach an image quality comparable to the conventional B-mode imaging with a much higher frame rate and could be further applied to Doppler imaging. Conventional coherence factor (CF) based beamformers for CPWC use only either the spatial coherence or angular coherence information, which limits the image quality. To take full advantage of the radio frequency (RF) data for better image quality, this paper proposes a united coherence factor (uCF) using both spatial and angular information for CPWC. The proposed uCF is applied to simulated, phantom and in vivo imaging data. We evaluate the performance of the proposed method by lateral resolution and contrast. For simulated images, the contrast ratio (CR) improvements are over 80%. In the phantom images, the maximum improvements of the lateral full width at half maximum (FWHM) and CR are 10% and 105%, respectively. To compare the most core differences, the spatial and angular methods are also presented in this paper. uCF is superior in lateral resolution improvement and contrast among the beamformers. In addition, the proposed uCF performance also shows good performance in the power Doppler experiment with improved image quality, which is further verified by the spatial similarity matrix of the Doppler image. Thus, the proposed method (uCF) has a great potential to be applied in CPWC for image quality improvement.
29 December 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Intraosseous ultrasound imaging can serve as a guiding tool for the placement of pedicle screws during spinal fusion surgery. Thus far, there has been limited scholarly exploration of methods for intraosseous multi-frequency ultrasound imaging, which can achieve simultaneous high resolution and deep penetration. The proposed method introduced a dynamic fusion strategy, grounded in wavelet transformation for the multi-frequency image decomposition. This strategy accomplished the effective amalgamation of high-frequency ultrasound images and low-frequency ultrasound images, enabling to obtain fused images with enhanced details and better overall image quality. A novel near-field effect elimination method was also proposed to improve the quality of ultrasound imaging in the near-field region. Experimental evaluations were conducted on isolated bovine circle bone and sheep spine with pedicle screw tracks. The fusion images are capable of effectively detecting areas within the pedicle screw track that have either ruptured or are in close proximity to rupture, even measuring the size of breaches. Evaluation criteria including information entropy, spatial frequency, average gradient, mutual information, structural similarity index, and edge information-based image fusion quality metric were employed to assess the fusion performance. Moreover, the influence of mother wavelet function selection and decomposition levels on computational complexity and fusion image quality was thoroughly discussed. The proposed method exhibited promising potential for intraosseous imaging navigation, which can aid in accurate diagnosis, treatment planning, and monitoring in fields such as orthopedics, surgery, and interventional procedures.