Yasuyuki Shiraishi

Yasuyuki Shiraishi

Auto-generated profile, based on publicly available information

Yasuyuki Shiraishi

Tohoku University

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2021 in Kidney and Dialysis
Verified
Journal Article
Open access
PDF file
Yasuhide NakayamaYasuhide Nakayama
Yasuhide Nakayama
RHRyuji Higashita
Ryuji Higashita
YSYasuyuki Shiraishi
Yasuyuki Shiraishi
TUTadahi Umeno
Tadahi Umeno
TTTsutomu Tajikawa
Tsutomu Tajikawa
SMSHINJI MIYAMOTO
SHINJI MIYAMOTO
Blood access is a lifeline for dialysis patients. However, serious problems such as stenosis or obstruction of access blood vessels, which are life-threatening conditions in daily clinical practice, still remain. One of the most promising candidates for solving these problems may be Biotube blood vessels. More than 20 years have passed since the development of in-body tissue architecture (iBTA), a technology for preparing tissues for autologous implantation in patients. The tissues obtained by iBTA do not elicit immunological rejection, which is one of the ultimate goals of regenerative medical engineering; however, their practical applications were quite challenging. The seemingly unorthodox iBTA concepts that do not follow the current pre-established medical system may not be readily accepted in general medicine. In contrast, there are many diseases that cannot be adequately addressed even with the latest and most advanced medical technology. However, iBTA may be able to save patients with serious diseases. It is natural that the development of high-risk medical devices that do not fit the corporate logic would be avoided. In order to actively treat such largely unattached diseases, we started Biotube Co., Ltd. with an aim to contribute to society. Biotubes induced by iBTA are collagenous tubular tissues prepared in the patient’s body for autologous implantation. The application of Biotubes as tissues for vascular implantation has been studied for many years. Biotubes may have excellent potential as small-diameter artificial blood vessels, one of the most difficult to clinically achieve. Their possibility is currently being confirmed in preclinical tests. Biotubes may save hundreds of thousands of patients worldwide annually from amputation. In addition, we aim to eliminate the recuring access vascular problems in millions of dialysis patients. This study provides an update on the current development status and future possibilities of Biotubes and their preparation molds, Biotube Makers.

9 February 2021 in Journal of Artificial Organs
Verified
Journal Article
Open access
PDF file
YSYasuyuki Shiraishi
Yasuyuki Shiraishi
YTYuma Tachizaki
Yuma Tachizaki
YIYusuke Inoue
Yusuke Inoue
MHMasaki Hayakawa
Masaki Hayakawa
AYAkihiro Yamada
Akihiro Yamada
TYTomoyuki Yambe
Tomoyuki Yambe
Chronic blood trauma caused by the shear stresses generated by mechanical circulatory support (MCS) systems is one of the major concerns to be considered during the development of ventricular assist devices. Large multimers with high-molecular-weight von Willebrand factor (VWF) are extended by the fluid forces in a shear flow and are cleaved by ADAMTS13. Since the mechanical revolving motions in artificial MCSs induce cleavage in large VWF multimers, nonsurgical bleeding associated with the MCS is likely to occur after mechanical hemodynamic support. In this study, the shear stress (~ 600 Pa) and exposure time related to hemolysis and VWF degradation were investigated using a newly designed mechanical shuttle shear flow tester. The device consisted of a pair of cylinders facing the test section of a small-sized pipe; both the cylinders were connected to composite mechanical heads with a sliding-sleeve structure for axial separation during the withdrawing motion. The influence of exposure time, in terms of the number of stress cycles, on hemolysis and VWF degradation was confirmed using fresh goat blood, and the differences in the rates of dissipation of the multimers were established. The plasma-free hemoglobin levels showed a logarithmic increase corresponding to the number of cycles, and the dissipation of large VWF multimers occurred within a few seconds under high shear stress flow conditions.

1 January 2021 in Advanced Biomedical Engineering
Verified
Journal Article
Open access
PDF file
AYAkihiro Yamada
Akihiro Yamada
YIYusuke Inoue
Yusuke Inoue
YSYasuyuki Shiraishi
Yasuyuki Shiraishi
TSTakashi Seki
Takashi Seki
TYTomoyuki Yambe
Tomoyuki Yambe
In traditional Chinese pulse diagnosis, the pulses of bilateral radial arteries are palpated by three fingers. In this study, a device that can objectively perform pulse diagnosis using multiple pressure sensors with a cuff was developed. The device has three pressure sensors in series and a cuff to apply external pressure load. Pulse waves were measured using the non-invasive pulse diagnostic device. The relationship of the data obtained from the proposed system with the diagnosis by the traditional method was examined. The study was conducted with the approval of the Ethics Committee in Tohoku University. Twelve adult male subjects were studied. Data of pulse waveforms recorded from the pulse diagnosis device, electrocardiogram, and continuous blood pressure measured at the fingertip were stored and analyzed. The pulse waves of the subjects were categorized as middle pulse, floating pulse, or sunken pulse according to pulse diagnosis in traditional Chinese medicine. Pulse–waveform data were obtained to measure the pulse–pressure changes, which showed different patterns of the rise time at the three measurement sites. Envelope analysis of the pulse waveform from the middle sensor revealed that the peak value of the pulse pressure increased during calculation stress compared to the resting state. It was possible to measure the pulse waves even when a higher external pressure was applied. Objective pulse-wave measurement using a method similar to that in traditional pulse diagnosis was realized, and pulse waveforms were measured using the proposed pulse diagnosis system.

1 July 2013
Verified
Conference Paper
Closed access
MHMohamed O. Hashem
Mohamed O. Hashem
AYA. Yamada
A. Yamada
YTYusuke Tsuboko
Yusuke Tsuboko
HMH. Muira
H. Muira
DHD. Homma
D. Homma
TYT. Yambe
T. Yambe
Diastolic counter-pulsation has been used to provide circulatory augmentation for short term cardiac support. The success of intra-aortic balloon pump (IABP) therapy has generated interest in long term counter-pulsation strategies to treat heart failure patients. The authors have been developing a totally implantable extra aortic pulsation device for the circulatory support of heart failure patients, using 150μm Ni-Ti anisotropic shape memory alloy (SMA) fibers. These fibers contract by Joule heating with an electric current supply. The special features of our design are as follow: non blood contacting, extra aortic pulsation function synchronizing with the native heart, a wrapping mechanical structure for the aorta in order to achieve its assistance as the aortomyoplsty and the extra aortic balloon pump. The device consisted of rubber silicone wall plates, serially connected for radial contraction. We examined the contractile function of the device, as well as it controlling methods; the phase delay parameter and the pulse width modulation, in a systemic mock circulatory system, with a pneumatically driven silicone left ventricle model, arterial rubber tubing, a peripheral resistance unit, and a venous reservoir. The device was secured around the aortic tubing with a counter-pulsation mode of 1-4 against the heartbeat. Pressure and flow waveforms were measured at the aortic outflow, as well as its driving condition of the contraction phase width and the phase delay. The device achieved its variable phase control for co-pulsation or counter-pulsation modes by changing the phase delay of the SMA fibers. Peak diastolic pressure significantly augmented, mean flow increased (p<;0.05) according to the pulse width modulation. Therefore the newly developed extra aortic counter-pulsation device using SMA fibers, through it controlling methods indicated its promising alternative extra aortic approach for non-blood contacting cardiovascular circulatory support.

15 September 2020 in Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
AFAoi Fukaya
Aoi Fukaya
YSYasuyuki Shiraishi
Yasuyuki Shiraishi
YIYusuke Inoue
Yusuke Inoue
AYAkihiko Yamada
Akihiko Yamada
GSGenta Sahara
Genta Sahara
TYTomoyuki Yambe
Tomoyuki Yambe

30 July 2021 in Journal of Environmental Engineering (Transactions of AIJ)
Verified
Journal Article
Open access
PDF file
KTKento Tomoda
Kento Tomoda
YSYasuyuki Shiraishi
Yasuyuki Shiraishi
Earth-to-air heat exchangers (EAHE) utilize the heat capacity of soil to pre-cool or pre-heat outside air (OA), and then introduce OA into the air handling unit to reduce the heat load of OA. However, at the operational phase, the control of an EAHE is not optimized (e.g., inefficient energy saving or lower quality of introduced air). It is also difficult to establish the optimal control rule that considering the future effects by sequential operations since the control response takes extremely long time. In this study, we focused on the reinforcement learning (RL) control, which does not require the construction of control rules. In RL, an agent learns to maximize reward in the state s within an environment, and this algorithm achieves its purpose by passing action a that maximizes reward to the environment. One of the advantages of RL is maximizing the cumulative reward instead of maximizing the sequential reward. For this reason, RL is suitable for unsteady problems. The purpose of this study is to establish the optimal control rules for an EAHE by RL. In this paper, we validate the RL control rule that achieve the two objectives in which decreasing the heat load of the fresh air handling unit (FAHU) and suppressing the occurrence of condensation in the EAHE. Firstly, we define the control problem for RL using the environment estimated by long-term performance prediction method of EAHEs based on CFD developed by authors. Then, we incorporate training logic to the environment and conduct the training of RL. Secondary, we implement the algorithm for efficient learning by defining rewards as the results of factual and counterfactual actions. Then, we verify the effectiveness of the RL control by comparing the RL control with the scheduled control, etc. Finally, we analyze the tendency of actions selected by RL. The reward is defined by a method of feeding back to the actions selected by the Agent to the relative rewards. This method compares and evaluates not only the results of factual action but also the results of counterfactual action based on the Counterfactual Predictor. This makes it possible to give immediate feedback to the Agent which action was appropriate. We call this method Factual and Counterfactual Reward Estimation (FCRE). As a result of RL using FCRE, it is possible to obtain rough policy in the early stages of the learning and high convergence of learning. Comparing the RL control with the scheduled control, heat load of FAHU is increased about 3%, but the occurrence of the condensation is extremely decreased by the RL control. It was confirmed that it is possible to control to achieve the above two objectives simultaneously by the RL control.