Serge Alexander Trines

Serge Alexander Trines

Auto-generated profile, based on publicly available information

Serge Alexander Trines

Department of Cardiology, Heart Lung Center, Leiden University Medical Center, Leiden, The Netherlands

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2008 in Heart
Verified
Journal Article
Closed access
PDF file
JLJ C Lekkerkerker
J C Lekkerkerker
CNCees van Nieuwkoop
Cees van Nieuwkoop
STS A Trines
S A Trines
JBJohanna (Anske) Gerarda van der Bom
Johanna (Anske) Gerarda van der Bom
ABA Bernards
A Bernards
LEL van Erven
L van Erven
Aims: A nested case-control study of 75 patients with cardiac device infections (CDI) and 75 matched controls was conducted to evaluate time course, risk factors, culture results and frequency of CDI. Methods and results: CDI occurred in 75/3410 (2.2%) device implantation and revision procedures, performed between 2000 and 2007. The time delay between device procedure and infection ranged from 0 to 64 months (mean 14 (SD 16)), 21 patients (28%) had an early infection (12 months). Of interest, 18 (24%) patients presented with an infection >24 months after the device-related procedure. Time delay until infection was significantly shorter when cultures were positive for micro-organisms compared to negative cultures (8 (12) vs 18 (18) months, p = 0.03). Pocket cultures in delayed infections remained more often negative (61% vs 23%, p = 0.01). Independent CDI risk factors were: device revision (odds ratio (OR) 3.67; 95% confidence interval (CI), 1.51 to 8.96), renal dysfunction defined as glomerular filtration rate <60 ml/min (OR 4.64; CI, 1.48 to 14.62) and oral anticoagulation use (OR 2.83; CI 1.20 to 6.68). Conclusion: CDI occurred in 2.2% of device procedures, with 24% occurring more than two years after the device-related procedure. Renal dysfunction, device revisions and oral anticoagulation are potent risk factors for CDI.

1 January 2011 in JACC
Verified
Journal Article
Closed access
LTLaurens F. Tops
Laurens F. Tops
VDVictoria Delgado
Victoria Delgado
Matteo BertiniMatteo Bertini
Matteo Bertini
NMNina Ajmone Marsan
Nina Ajmone Marsan
DUDennis W. Den Uijl
Dennis W. Den Uijl
JBJeroen J. Bax
Jeroen J. Bax

31 January 2014 in European Heart Journal
Verified
Journal Article
Open access
PDF file
Elena ArbeloElena Arbelo
Elena Arbelo
JBJosep Brugada
Josep Brugada
GHGerhard Hindricks
Gerhard Hindricks
Aldo Pietro MaggioniAldo Pietro Maggioni
Aldo Pietro Maggioni
LTLuigi Tavazzi
Luigi Tavazzi
AIAtrial Fibrillation Ablation Pilot Study Investigators
Atrial Fibrillation Ablation Pilot Study Investigators
The Atrial Fibrillation Ablation Pilot Study is a prospective registry designed to describe the clinical epidemiology of patients undergoing an atrial fibrillation (AFib) ablation, and the diagnostic/therapeutic processes applied across Europe. The aims of the 1-year follow-up were to analyse how centres assess in routine clinical practice the success of the procedure and to evaluate the success rate and long-term safety/complications. Seventy-two centres in 10 European countries were asked to enrol 20 consecutive patients undergoing a first AFib ablation procedure. A web-based case report form captured information on pre-procedural, procedural, and 1-year follow-up data. Between October 2010 and May 2011, 1410 patients were included and 1391 underwent an AFib ablation (98.7%). A total of 1300 patients (93.5%) completed a follow-up control 367 ± 42 days after the procedure. Arrhythmia documentation was done by an electrocardiogram in 76%, Holter-monitoring in 52%, transtelephonic monitoring in 8%, and/or implanted systems in 4.5%. Over 50% became asymptomatic. Twenty-one per cent were re-admitted due to post-ablation arrhythmias. Success without antiarrhythmic drugs was achieved in 40.7% of patients (43.7% in paroxysmal AF; 30.2% in persistent AF; 36.7% in long-lasting persistent AF). A second ablation was required in 18% of the cases and 43.4% were under antiarrhythmic treatment. Thirty-three patients (2.5%) suffered an adverse event, 272 (21%) experienced a left atrial tachycardia, and 4 patients died (1 haemorrhagic stroke, 1 ventricular fibrillation in a patient with ischaemic heart disease, 1 cancer, and 1 of unknown cause). The AFib Ablation Pilot Study provided crucial information on the epidemiology, management, and outcomes of catheter ablation of AFib in a real-world setting. The methods used to assess the success of the procedure appeared at least suboptimal. Even in this context, the 12-month success rate appears to be somewhat lower to the one reported clinical trials.

1 April 2009 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
VDVictoria Delgado
Victoria Delgado
LTLaurens F. Tops
Laurens F. Tops
STSerge A. Trines
Serge A. Trines
KZKatja Zeppenfeld
Katja Zeppenfeld
NMNina Ajmone Marsan
Nina Ajmone Marsan
JBJeroen J. Bax
Jeroen J. Bax
Chronic right ventricular (RV) apical pacing has a detrimental effect on left ventricular (LV) function. However, the acute effects of RV apical pacing on LV mechanics remain unclear. The purpose of the study was to assess the acute impact of RV apical pacing on global LV function, evaluating LV contraction synchrony and LV shortening and twist, using 2D speckle-tracking strain imaging. A group of 25 patients with structural normal hearts referred for electrophysiological study were studied. Two-dimensional echocardiography was performed at baseline and during RV apical pacing at the time of the electrophysiological study. Changes in LV synchrony and mechanics (longitudinal shortening and twist) were assessed using speckle-tracking strain imaging. In addition, 25 controls matched by age, sex, and LV function were studied during sinus rhythm. The group of patients (44+/-12 years, 10 men) and the group of controls (48+/-3 years, 8 men) showed comparable LV synchrony, LV longitudinal shortening, and LV twist at baseline. However, during RV apical pacing, a more dyssynchronous LV contraction was observed in the patients (from 21 ms [Q(1):10, Q(3):53] to 91 ms [Q(1):40, Q(3):204], P<0.001) together with an impairment in LV longitudinal shortening (from -18.3+/-3.5% to -11.8+/-3.6%, P<0.001) and in LV twist (from 12.4+/-3.7 degrees to 9.7+/-2.6 degrees , P=0.001). During RV apical pacing, an acute induction of LV dyssynchrony is observed. In addition, LV longitudinal shortening and LV twist are acutely impaired.

24 May 2012 in EP Europace
Verified
Journal Article
Open access
PDF file
Elena ArbeloElena Arbelo
Elena Arbelo
JBJosep Brugada
Josep Brugada
GHGerhard Hindricks
Gerhard Hindricks
Aldo Pietro MaggioniAldo Pietro Maggioni
Aldo Pietro Maggioni
LTLuigi Tavazzi
Luigi Tavazzi
OIon behalf of the Atrial Fibrillation Ablation Pilot Study Investigators
on behalf of the Atrial Fibrillation Ablation Pilot Study Investigators
The Atrial Fibrillation Ablation Pilot Study is a prospective, multinational registry conducted by the European Heart Rhythm Association of the European Society of Cardiology that has been designed to describe the clinical epidemiology of patients undergoing an atrial fibrillation (AFib) ablation procedure, and the diagnostic/therapeutic processes applied in these patients across Europe. We present the results of the short-term (in-hospital) analysis. A total of 72 centres in 10 European countries were asked to enrol 20 consecutive patients scheduled for a first AFib ablation procedure. Between October 2010 and May 2011, 1410 patients were included, of which 1391 underwent an AFib ablation (98.7%). The median age was 60 years [inter-quartile range (IQR) 52–66], and 28% were females. Two-thirds presented paroxysmal AFib and 38% lone AFib. Symptoms were present in 86%. The indications for ablation were mostly symptomatic AFib, but in over a third of patients there was also a desire for a drug-free lifestyle and the maintenance of sinus rhythm. Pulmonary vein isolation was attempted in 98.4% of patients, the roof line in 21.3% and the mitral isthmus line in 12.8%. Complex-fractionated atrial electrograms were targeted in 17.9% and the ganglionated plexi in 3.3%. Complications occurred in 7.7%, of which 1.7% was major (i.e. cardiac perforation, myocardial infraction, endocarditis, cardiac arrest, stroke, hemothorax, pneumothorax, and sepsis). The median duration of hospitalization was 3 days (IQR 2–4). At discharge, 91.4% of patients were in sinus rhythm, 88.3% of patients were given vitamin K antagonists, and 67% antiarrhythmic medication. There was one death after the ablation procedure. The AFib Ablation Pilot Study provides crucial information on AF ablation in clinical practice across Europe. These data are relevant for further improvement of the management strategies of patients suffering from atrial fibrillation.

1 June 2013 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
PDF file
SPSebastiaan R.D. Piers
Sebastiaan R.D. Piers
DLDarryl P. Leong
Darryl P. Leong
CTCarine F.B. van Huls van Taxis
Carine F.B. van Huls van Taxis
MTMohammad Tayyebi
Mohammad Tayyebi
STSerge A. Trines
Serge A. Trines
KZKatja Zeppenfeld
Katja Zeppenfeld
Background—: Ablation failure and recurrence rates after ventricular tachycardia (VT) ablation in nonischemic cardiomyopathy are high and the optimal procedural end point is not well defined. This study assessed the outcome after ablation, the impact of noninducibility, and other potential predictors of VT recurrence. Methods and Results—: Forty-five patients with nonischemic cardiomyopathy (60±16 years; left ventricular ejection fraction, 44±14%) accepted for VT ablation were included. Epicardial mapping was performed in 29 (64%). A median of 2 (first-to-third quartile, 2–4) VTs (cycle length, 342±77 ms) were induced per patient. After ablation, the complete programmed electric stimulation protocol (3 drive cycle length, 3 extrastimuli ≥200 ms, and burst≥2 sites) was repeated. Complete success (noninducibility of any monomorphic VT) was achieved in 17 patients (38%), partial success (elimination of clinical VT, persistent inducibility of nonclinical VT) in 17 patients (38%), and failure (persistent inducibility of clinical VT) in 11 patients (24%). During 25±15 months of follow-up, VT occurred in 24 patients (53%), but the 6-month VT burden was reduced by ≥75% in 79%. Recurrence rates were low after complete procedural success (18%), but high after both partial success (77%) and failure (73%). Non-complete procedural success was the strongest predictor of VT recurrence (hazard ratio, 8.20; 95% confidence interval, 2.37–28.43; P =0.001). Conclusions—: Although 53% of patients had VT during follow-up, the 6-month VT burden was decreased by ≥75% in 79%. Recurrence rates are low after complete procedural success, but high after both partial success and failure. Non-complete procedural success was the strongest predictor of VT recurrence.