Protection devices are extensively utilized in direct current (DC) systems to ensure their normal operation and safety. However, series arc faults that establish current paths in the air between conductors introduce arc impedance to the system. Consequently, they can result in a decrease of current, and thus conventional protection devices may not be triggered. Undetected series arc faults can cause malfunctions and even lead to fire hazards. Therefore, a series arc-fault detection system is essential to DC systems to operate reliably and efficiently. In this paper, a series arc-fault detection system based on arc time-frequency signatures extracted by a modified empirical mode decomposition (EMD) technique and using a support vector machine (SVM) algorithm in decision making is proposed for DC systems. The oscillatory frequencies from the arc current are decomposed by the EMD with an analysis of the Hurst exponent ( ${H}$ ) to reject interference from the power electronics noise. ${H}$ analyzes the trend of a signal and the intrinsic oscillations of the signal are those with values of ${H}$ larger than 1/2. Comparing to traditional filters or wavelet transforms, this method does not require knowledge of the frequency range of the interference which varies from system to system. The capability and applicability of the proposed technique are validated in a photovoltaic system. The effectiveness of arc-fault detection is significantly improved by this technique because it can acquire sufficient and accurate arc signatures and it does not need to predefine various thresholds.
Fast online detection of inter-turn short-circuit faults for permanent magnet synchronous machines (PMSMs) is a challenging task. Previous attempts based on phase currents or back EMF monitoring lack the capability to accurately locate the inter-turn short-circuit faults in stator windings. This work proposed a new approach to online inter-turn short-circuit fault detection for PMSMs by means of sensing the external stray magnetic field outside the motor stator yoke. The stray magnetic field provides the information about the phase currents as well as the status of stator windings; thus, the location of inter-turn short-circuit fault can be detected accordingly. In this work, the inter-turn short-circuit model and the stray magnetic flux model for PMSMs were theoretically analyzed. Both FEM simulations and experiments have been presented to validate the effectiveness of the proposed approach. A sensor array composed of 24 sensitive tunneling magnetoresistive (TMR) sensor units was employed to measure the stray magnetic field distribution outside the PMSM stator yoke. The experimental results show that both the location and severity of the inter-turn short-circuit fault in PMSMs were effectively detected using the proposed approach.
Noncontact monitoring technique of mechanical and electrical states is increasingly attractive for the overhead transmission system. This paper proposes a new technique to detect the tower inclination and transmission line sag, and measure transmission current simultaneously. The key of this technique is to use the ground magnetoresistive (MR) sensor to measure the magnetic flux density along the center line from the three-phase transmission lines. Moreover, the magnetic field (MF) calculation formulas for a tilted tower are given in this paper. Finally, with MF calculation formulas, an algorithm based on artificial immune system (AIS) is applied to estimate the transmission line sag and tower tilt angles, and reconstruct currents. Model simulations of an overhead transmission system are carried out to verify the idea. The simulation results validate the feasibility of this noncontact approach to estimate mechanical parameters and reconstruct electrical parameters for overhead transmission system.
22 March 2022 in IEEE Transactions on Industrial Electronics
The detection and location of eccentricity faults in a permanent magnet synchronous generator (PMSG) become increasingly essential, especially in safety-critical applications. However, the existing approaches for monitoring eccentricity subject to many limitations. In this article, a novel method for online detection and location of the eccentricity fault in a PMSG is proposed based on the external magnetic sensing. The noninvasiveness facilitates installation and maintenance work. In this article, the effect of different eccentricity faults on the external leakage flux density is analyzed theoretically with the magnetic equivalent circuit method first. Then, two indicators are proposed for detecting static eccentricity (SE) and dynamic eccentricity (DE), respectively. The amplitudes of the SE and DE indicators are proportional to the fault degree. The angle of the SE indicator proves to be the direction of SE. Meanwhile, two indicators show excellent robustness and are independent of loads and rotation speed. Moreover, these indicators can be applied in any surface-mounted PMSG with a three-multiple number of slots. Accordingly, an algorithm to diagnose the eccentricity fault is shown based on two indicators from three sensing points outside. The computation of the method is light, which leads to fast detection speed. Finally, the accurate results in multioperating conditions from simulations and experiments verify the feasibility of the proposed approach.
15 April 2021 in IEEE Transactions on Transportation Electrification
Recently, detecting the magnet defect fault in permanent magnet synchronous generators (PMSGs) is still challenging. The previous work mainly focuses on the phase current, back electromotive force, or searching coils. However, these methods are sometimes limited due to the machine configuration, being computationally complex, or even being intrusive to the system. This article presents a new method for the online detection of the magnet defect in a PMSG simultaneously. This method is based on the leakage flux outside the generator, which is noninvasive. In the practical application, the leakage flux is measured by magnetic sensors mounted outside a PMSG under various operating conditions. First, the external leakage flux is derived theoretically with the magnetic equivalent circuit when one defective rotor magnet exists in a PMSG. Then, the external leakage flux is proved to contain information about the health condition of inside magnets during the machine operation. Subsequently, the permanent magnet defect indicator $F_{\mathrm {ind}}$ is proposed for analyzing the condition of the rotor magnets in detail. Finally, both simulation and experiment results verify the efficacy of the proposed method.
Monitoring power quality in microgrids is gaining increasing attention in recent years due to the popularity of microgrids and power quality disturbances caused by renewable energies. Many techniques based on artificial neural networks (ANNs) are proposed for monitoring the power quality with no need to pre-set thresholds. However, the necessity of retraining the ANN is a big problem when the electrical parameters vary. This paper proposes a new approach to detect and classify the power quality disturbances accurately in multi microgrids based on electromagnetic sensing and portability-enhanced ANN. The proposed ANN-based approach avoids the retraining of weights, when the voltage, current and frequency varies with microgrids. Two steps are critical for achieving the portability of the ANN in various microgrids, which are pre-normalization and using the same maximum and minimum feature vectors for feature matrix normalization. Meanwhile, the electromagnetic sensing facilitates non-intrusive monitoring and easy installation. The high accuracy of simulation and experimental results in various scenarios validate the effectiveness and efficiency of this portable and non-invasive approach for monitoring power quality in multi microgrids without retraining ANN.