16 July 2021 in IEEE Transactions on Transportation Electrification
Adopting dry-type on-board traction transformer (OBTT) is one of the main ways to reduce the weight of electric traction systems, and its thermal characteristics are crucial for the safe operation of high-speed electric multiple units (EMUs). However, the existing thermal modeling methods either cannot realize the fast calculation of thermal characteristics of dry-type OBTT, or cannot accurately obtain the turbulence heat-transfer intensity when using the high-speed train-induced wind cooling. This article proposes an efficient method for dry-type OBTT thermal characteristics calculation. First, the thermal network of the winding area is proposed considering the thermal developing region of the air duct and the heat flow in the insulation paper between conductors. Then, the effects of key parameters on convective heat-transfer intensity are obtained by computational fluid dynamics (CFD) parametric sweeps, and then a novel local Nusselt number correlation for accurately calculating the turbulent convective thermal resistance is proposed. Finally, validation is performed with an experimental setup. The experimental results show that the computationally efficient thermal network model proposed in this article can quickly obtain the winding temperature distribution and the location of the hot-spot temperature. Moreover, the thermal analysis of a 6.3 MVA dry-type OBTT was conducted using the proposed modeling method.
11 March 2019 in IEEE Transactions on Power Delivery
In order to dig out more potential of design parameters besides nameplate information, a set of pre-physical modelling methods was proposed and integrated into the dynamic thermal model-ling procedure, aiming to optimize the key thermal parameters individually. In this method, a global oil momentum model was created considering the flow resistance, and for the problem of heat transfer between windings, oil flow and radiator, a whole oil flow thermal model was established based on heat transfer principle and energy conservation. Then, the double logarithmic linear regression was applied to quantify the value of the exponents. According to the overload heat run tests, the temperature calculated by the existing models during multiple overloads is obviously different from the measured temperature, while the improved dynamic thermal modelling procedure with optimized thermal parameters attains estimates more accurately.
24 November 2022 in IEEE Transactions on Transportation Electrification
Using the dry-type on-board traction transformer cooled by train-induced wind is an effective way to realize the lightweight of on-board equipment. However, the existing small capacity fan cooled dry-type on-board traction transformer cannot meet the power requirements of the high-speed electric multiple unit. For the large capacity dry-type on-board traction transformer, the lack of mathematical models that can reflect the relationship between hotspot temperature and design parameters limits its development. This paper aims to propose an optimization method for large capacity dry-type on-board traction transformer. First, the user-defined function based computational fluid dynamics modelling method for dry-type on-board traction transformer is proposed and validated to accurately obtain the winding hotspot temperature. Then, the response surface models of winding hotspot temperature are firstly proposed based on the response surface methodology. Finally, the lightweight optimization of a 6.3 MVA dry-type on-board traction transformer is completed, and the influence of design parameters on the weight reduction is studied. Under the conservative optimization strategy, the total weight of dry-type on-board traction transformer is reduced to 3650.40 kg, which is reduced by 38.55% compared with the oil cooled on-board traction transformer with the same rated capacity. This paper provides an efficient and feasible method and regular guidance for the lightweight optimal design of dry-type on-board traction transformer, and the obtained response surface models can be used for the optimization of similar dry-type on-board traction transformer under different specific needs.
28 October 2022 in High Voltage
Thermal characteristic is one of the key performances of dry‐type on‐board traction transformer (D‐OBTT), which directly affects the operation safety of the new generation electric multiple units. However, due to the particularity of train‐induced wind cooling mode of D‐OBTT, the existing efficient thermal modelling methods cannot be used under fluctuating air velocity and load. A time‐saving transient thermal model for D‐OBTT is proposed. First, the framework of the transient thermal network model (TTNM) is proposed considering the coexistence of non‐fully and fully developed state of the train‐induced wind and the addition heat flow in the solid domain. Then, a novel formula for calculating the length of non‐fully developed section considering the geometric dimensions and heat flux density is proposed based on computational fluid dynamics (CFD) parametric sweeps for the first time. The accuracy of TTNM is validated by a D‐OBTT experimental setup, and the time consumption is significantly reduced compared with CFD.
6 April 2023 in IEEE Transactions on Power Delivery
Multiple strokes (MS) is the primary factor leading to the failure of electrical equipment. Arrester, as the critical lightning protective instrument, its service status is directly relevant to the stability of transmission system operation. Meanwhile, MS also significantly accelerates the impulse aging of arresters and ultimately causes malfunction. This paper proposes a method to evaluate the impulse aging of arresters under MS based on frequency domain dielectric spectroscopy (FDS). Firstly, MS experiments are performed, and then the FDS parameters of arresters are measured. Subsequently, the improved Havriliak–Negami equation (IHNE) is developed to explicitly analyze the dielectric relaxation process of arresters. Additionally, an improved metaheuristic algorithm is presented to identify the parameters in IHNE based on FDS, which has significant parameter identification. Eventually, the impulse aging evaluation model is established. Simultaneously, the condition of two types of arresters (including new and used arrester in service on transmission lines) are estimated based on the evaluation method presented in this paper. The maximum absolute errors are 0.73 times and 1.2 times, respectively, fully validating the effectiveness of the presented method. The investigation of this paper can provide a direct foundation for the replacement and overhaul of line arresters.
2 September 2025 in IEEE Transactions on Instrumentation and Measurement
The calculation of the dynamic temperature distribution of on-board traction transformers in high-speed electric multiple unit (EMU) is a key step in the verification of the rationality of the design, the assessment of insulation status, and other thermal related work. However, for dry-type on-board traction transformers (D-OBTTs) that are rapidly developing in the context of on-board equipment lightweight, due to their special cooling mode, existing dynamic thermal modeling methods cannot be directly applied. In this article, a dynamic temperature distribution calculation method applicable to D-OBTT is proposed. First, a dynamic thermal network modeling method for the winding area is presented. Then, a convection heat transfer intensity model applicable to the air duct area was obtained based on the dimensional analysis theory. Furthermore, a lumped parameter thermal-circuit model was constructed to obtain the necessary reference temperature in the dynamic thermal network model. Finally, a thermal test under dynamic traction load was conducted on the experimental setup to validate the proposed model. The experimental results indicate that the model proposed in this article has sufficient accuracy and computational efficiency, thus providing an efficient and reliable dynamic temperature distribution calculation method for the optimal design and lifespan evaluation of D-OBTT.