Mojtaba Saki

Mojtaba Saki

Auto-generated profile, based on publicly available information

Mojtaba Saki

Department of Electrical Engineering and Computing, Engineering Faculty, Shahed University of Tehran, Tehran, Iran

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2024 in IEEE Access
Verified
Journal Article
Open access
MRMohammad Amin Rezaei
Mohammad Amin Rezaei
AFArman Fathollahi
Arman Fathollahi
EAEhsan Akbari
Ehsan Akbari
MSMojtaba Saki
Mojtaba Saki
EKErfan Khorgami
Erfan Khorgami
Amir MosaviAmir Mosavi
Amir Mosavi
Capacitor banks (CBs) play a crucial role in energy storage and frequency control within autonomous microgrids. However, the impact of internal capacitor configurations, varying in terms of equivalent series resistance (ESR), capacitance, and rated voltage, on CB degradation, reliability, and peak current remains an understudied aspect. Moreover, the absence of a capacitance degradation coefficient in the standard MIL-HDBK-217 equations for predicting the reliability of electrolytic capacitors poses a significant challenge. To address these issues, this study examines a microgrid composed of diverse renewable energy systems, featuring nine distinct CB arrangements. The design of CBs considers both capacitance and peak output current individually. An evaluation is conducted to compare construction costs, lifetimes, and peak output currents across all layouts. Additionally, a novel formula is introduced to estimate the reliability and lifetime of CBs, while an existing formula for calculating CB peak output current is enhanced. The research explores the impact of ambient temperature and capacitor voltage on the reliability of various capacitor designs, proposing a novel framework for assessing CB reliability based on MIL-HDBK-338B, which accounts for both short-circuit and open-circuit faults. The practicality of these findings is confirmed through a comparison of experimental and simulation results. The inverter operation video, simulation, and all production data including PCB and processor codes are also attached.

14 October 2022 in IEEE Access
Verified
Journal Article
Open access
EAEhsan Akbari
Ehsan Akbari
ATAli Reza Teimouri
Ali Reza Teimouri
MSMojtaba Saki
Mojtaba Saki
MRMohammad Amin Rezaei
Mohammad Amin Rezaei
Jiefeng HuJiefeng Hu
Jiefeng Hu
Amir MosaviAmir Mosavi
Amir Mosavi
Cascaded multilevel inverters (MLIs) generate an output voltage using series-connected power modules that employ standard configurations of low-voltage components. Each module may employ one or more switched capacitors to double or quadruple its input voltage. The higher number of switched capacitors and semiconductor switches in MLIs compared to conventional two-level inverters has led to concerns about overall system reliability. A fault-tolerant design can mitigate this reliability issue. If one part of the system fails, the MLI can continue its planned operation at a reduced level rather than the entire system failing, which makes the fault tolerance of the MLI particularly important. In this paper, a novel fault location technique is presented that leads to a significant reduction in fault location detection time based on the reliability priority of the components of the proposed fault-tolerant switched capacitor cascaded MLI (CSCMLI). The main contribution of this paper is to reduce the number of MLI switches under fault conditions while operating at lower levels. The fault-tolerant inverter requires fewer switches at higher reliability, and the comparison with similar MLIs shows a faster dynamic response of fault detection and reduced fault location detection time. The experimental results confirm the effectiveness of the presented methods applied in the CSCMLI. Also, all experimental data including processor code, schematic, PCB, and video of CSCMLI operation are attached.