19 February 2018 in IEEE Transactions on Industrial Electronics
The low-frequency magnetic field immunity test usually requires a homogenous magnetic field inside a cubic space to demonstrate the interference field. However, the 3-dB homogenous magnetic field region generated by the commonly used the Helmholtz coil is not a cubic space, which indicates a suboptimal design. This paper proposes an improved two-coil configuration for low-frequency magnetic field immunity tests and other similar applications, and discusses two key issues related to its field inhomogeneity, namely winding cross section and installation misalignment. Three simple formulas are concluded to establish a relationship between the parameters of the improved coil and the required homogenous magnetic field. These formulas enable the parametric and fast design of the improved coil. A comparison with the Helmholtz coil shows that the improved coil can reduce over 10% conductor mass cost when the same homogenous magnetic field is required. In addition, the effects of winding cross section and installation misalignments on the field homogeneity are analyzed, and valuable suggestions are provided for the design of a practical coil system. At last, an experimental test and a finite-element analysis are performed. The results are compared with the theoretical analysis, and the validity of the main conclusions in this paper is proved.
2 July 2019 in IEEE Transactions on Applied Superconductivity
China Fusion Engineering Test Reactor (CFETR) is a new tokamak device, which is one design option under the consideration of the China National Integration Design Group employs superconducting magnets. The main target of this project is to build a self-sufficiency fusion engineering tokamak reactor with its fusion power is 50-200 MW. Toroidal Field (TF) coils, Center Solenoid (CS) coils and Poloidal Field (PF) coils, whose rated current range from 52.9 kA to 90 kA, produce the magnetic field for plasma generation and confinement. The core of Quench Protection Unit (QPU) is to divert the coil current into Discharge Resistor (DR) by using commutation technology, which should be determined by the rated current and voltage requirement of magnets. Different kinds of technologies for QPU are considered, and an advanced commutation technology composed of a mechanical Bypass Switch (BPS), Vacuum Circuit Breaker (VCB) and LC commutation circuit based on artificial current zero technology has been worked out to meet the current and voltage requirement (10 kV/100 kA). To provide a faster and more reliable removal of the energy stored in those superconducting coils, this paper detailed analyzes the feasibility of a commutation scheme based on artificial current zero technology by analyzing and simulating each stage of the commutation process under such large rated current and high voltage conditions. Both analysis and simulation results verified that the operating reliability of QPU can be guaranteed by this 100 kA DC commutation scheme.
31 August 2018 in IEEE Transactions on Components, Packaging and Manufacturing Technology
The Integrated Gate Commutated Thyristors (IGCT) is widely used in power electronics system such as power converter and Solid-State Circuit Breaker (SSCB). Higher operating temperature of the IGCT will lead to the increase of the failure rate and the reduction of the reliability. In this paper, a thermal analysis of the IGCT water-cooled heat sink for the SSCB rated for current of 7.5 kA is described. In order to ensure the reliability of the paralleled connection IGCTs, two schemes of the IGCT water-cooled heat sink based on S-type fluid tube and Archimedes spiral fluid tube for the SSCB are studied. Through the three-dimensional finite element method simulation, the comparison of results show that Archimedes spiral fluid tube has lower thermal resistance and pressure drop under the same heat power condition and the water flow rate. At last, the corresponding test results indicate that the junction temperature of the IGCTs will not exceed 100 °C by using the water-cooled heat sink based on the Archimedes spiral fluid tube which can meet the design requirement.
1 June 2016 in IEEE Transactions on Plasma Science
This paper presents the design and testing of the full scale prototype of the international thermonuclear experimental reactor (ITER) poloidial field converter unit (PFCU), which is mainly composed of converter transformer, converter module, external bypass, and dc reactors with a rated capacity of 82 MVA and a rated dc current of 55 kA. Considering the space limitation, the high safety and reliability requirements, the nonsame-phase antiparallel connection structure, and the fault suppression capability criterion are applied in the prototype design. After the completion of the preliminary design of the PFCU in summer 2012, the detailed prototype structure design and the manufacturing of the PFCU were launched and completed at the end of 2013, then the following main type tests, including short circuit current test and temperature rise test on the main components of the PFCU, have been done on the ITER power supply test platform at ASIPP site. In addition, the PFCU integration test has also been done to verify the system operation performance. The prototype test results are well in compliance with the design requirements of the ITER PF converter system. It indicates that the full scale prototype research and development of PFCU has been accomplished successfully.
7 June 2016 in IEEE Transactions on Plasma Science
This paper describes the coupled force and natural convection analysis technique to calculate the increase in temperature of the international thermonuclear experimental reactor poloidal field converter water-cooling dc busbar. The increase in temperature of the busbar is due to Joule's losses and heat dissipation by cooling water and air convection. Joule's loss is calculated by the 3-D eddy-current field analysis and used as the input for the thermal fluid analysis. Energy conservation equation is coded and the primary natural convection coefficient on the external surface of the dc busbar is calculated. An interactive procedure is proposed to predict the busbar operation behavior. Two sets of computational fluid dynamics analysis are presented to calculate the temperature distribution of the dc busbar, cooling water, and air. One is to solve the force convection heat transfer problem inside the busbar cooling water channel with the primary equivalent natural convection coefficient calculated in energy conservation equation. The other is to solve the natural convection behavior on the dc busbar external wall with the equivalent force convection coefficient on the busbar internal cooling channel. The final temperature distribution result is determined by the two heat convection coefficient difference between these two simulations. The accuracy of the technique developed is verified by comparing the measured and the simulated temperature in a prototype thermal test, which proves the high efficiency and accuracy of the proposed approach in the design of water-cooling dc busbar.
21 February 2020 in IEEE Transactions on Plasma Science
The quench protection system in a large-scale superconductor test facility (LSTF) aims to protect the superconducting magnets from being damaged by long time and severe conducting current. A super-high pulse current from oscillation between a pulse inductor and a storage capacitor flows reversely into the main circuit to force the current in the main circuit cross zero, which ensures the reliable turn-off of the mechanical switch to protect the superconducting magnets. Furthermore, the pulse inductor also plays an essential role in adjusting the pulsewidth and the limiting pulse peak value. For the inductor, the pulse current is up to 130 kA and the rated inductance is 30 μH. To release the electromagnetic (EM) force largely and reinforce the structure and insulation properties, a circular multi-winding structure with epoxy resin-casting technique is presented. Based on the 2-D/3-D model built in finite element analysis software, the structure resist, deformation, heat, and EM environment of the design are simulated. The terminals are also optimized to minimize the damage from the EM force and extend the operation life of the inductor. In addition, a fatigue analysis is carried out to estimate the working life of the inductor and verify the reliability of the structure under the 130-kA pulse current working condition.