The growing demand for electricity and the rapid proliferation of electric vehicles present significant challenges for low-voltage distribution networks, particularly their critical components, such as distribution transformers. Infrastructure designed for traditional loads faces the risk of overloading due to high peak loads caused by uncontrolled electric vehicles charging. This paper develops a comprehensive methodological approach to assessing the impact of charging processes on the lifespan of distribution transformers, considering various levels of electric vehicles penetration, combinations of electrical loads, and local operating conditions. The study is based on the hypothesis that is optimizing charging schedules, particularly shifting charging to off-peak hours, can significantly reduce transformer ageing rates and enhance the reliability of the power supply. The proposed methodology employs a fuzzy logic-based model that integrates numerous factors affecting transformer performance, including ambient temperature, harmonic distortion, reactive power compensation, reverse energy flows from photovoltaic installations, and overload risks. The study examines charging scenarios on demand, off-peak charging, and a combined mode with vehicle-to-home (V2H) technology, which integrates electric vehicles as a backup energy source for household needs. The results demonstrate that such approaches can minimize network upgrade costs while maintaining network stability even under high electric vehicles penetration levels. The presented methodology provides a foundation for developing adaptive energy resource management strategies aimed at improving distribution system resilience, extending transformer lifespan, and enhancing the economic efficiency of the infrastructure.
5 July 2024 in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
Currently, we are moving towards more ecological modes of transport. As a result, the demand for electric vehicles is growing exponentially, and new loads, related to charging, can negatively affect the operation of electrical grids and their elements. Concurrent and uncontrolled charging of electric vehicles can cause a blackout. Considering the stochastic nature of the additional load from electric cars, it is difficult to predict such a load by analytical methods. The fuzzy logic approach can be used to formalize the tasks with ambiguity. In this paper, a fuzzy-based block diagram of the algorithm was developed in the MATLAB-Simulink environment for evaluating the impact of the charging load of electric vehicles on the aging of transformers, as well as a model was built and the effect of various penetrations of electric cars was evaluated. The fuzzy logic-based model includes the effects of ambient temperature, power quality, and overloads. It contains a diagnostic part that warns the dispatcher of the power distribution network about possible problems, providing up-to-date information about the state of the transformer. In addition, the efficiency of photovoltaic generators to increase the service life of distribution transformers was analyzed. The results show that photovoltaic power plants are not effective enough for high levels of electric vehicle penetration, and more advanced strategies should be used.
9 July 2025 in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
The increasing popularity of electric vehicles and their widespread adoption in everyday life present numerous technical and operational challenges for electric distribution networks, particularly their critical components, such as distribution transformers. High peak loads caused by uncontrolled electric vehicles charging processes can lead to overloads and reduced equipment lifespan, increasing infrastructure maintenance and modernization costs. This paper discusses and proposes a practically oriented method for optimal charging of electric vehicles based on a comprehensive approach using fuzzy logic. This approach enables a detailed assessment of the charging processes' impact on distribution networks, including analysis of harmonic voltage distortions, temperature operating conditions, and variable transformer loading levels. The study examines various charging scenarios: on-demand charging, off-peak charging, and a combined mode employing Vehicle-to-Home (V2H) technology for bidirectional energy exchange between the electric vehicles and household. The analysis results demonstrate that optimizing charging schedules significantly reduces the risk of network and transformer overloads, decreases their ageing rate, ensures higher power quality, and enables avoiding or substantially reducing financial costs associated with energy infrastructure upgrades. The proposed method considers local operational conditions, facilitating its effective implementation in actual electricity distribution systems by adapting to individual user requirements and network specifics.
27 June 2024 in Electrical Engineering and Power Engineering
Purpose. This paper aims to evaluate the negative factors that affect the aging of power distribution transformers, develop a fuzzy control model for their compensation, and study the results of applying the proposed model to different modes of the electrical power network. Methodology. The mathematical method of fuzzy logic was used to implement the control system of the power grid operating modes. Findings. The article presents a structure based on fuzzy logic for compensating depreciation factors of distribution transformers. A tuning algorithm and measures were developed to optimize the transformer's load level and power factor. The developed model analyzes the parameters and factors affecting the normal operation of the transformer and warns of dangerous factors that threaten reliability and may lead to a malfunction. In addition, the efficiency of PV generating stations, shunt capacitor banks, and energy storage systems installed on the secondary voltage side to preserve the service life of distribution transformers was analyzed and discussed. Originality. The paper further develops the fuzzy logic models used to optimize the operation of the power grid and compensate for the aging factors of power distribution transformers Practical value. The results obtained in the paper can be used to build an optimal system for controlling the operation modes of the electric power grid, which reduces the factors that accelerate the aging of power distribution transformers.
1 July 2024 in Problems of Informatization and Management
Запропоновано прикладну методику швидкого переходу від заздалегідь оптимізованого опорного алгоритму управління до його дискретизованого (програмного) аналога для потреб дискретного управління об'єктами, які працюють за принципом on-off. Ця методика може бути корисною при проектуванні та реалізації бюджетних систем автоматичного управління, зокрема систем побудованих на основі єдиної інформаційно-керуючої мережі за клієнт-серверним принципом. Застосування методики передбачає ряд етапів, а саме: базова формалізація контурів регулювання та отримання оптимальних перехідних процесів за допомогою моделювання (у статті реалізовано за допомогою середовища MatLab Simulink), виявлення оптимального опорного алгоритму управління та його параметрів, побудова адаптаційної характеристики, soft-реалізація адаптаційної характеристики на рівні контролера.
5 July 2024 in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
Currently, there is a constant growth of distributed energy resources, it became necessary to integrate them into the power grid. However, the integration process must consider not only the control parameters of the distributed energy resource but also the parallel operation of several such resources, the parameters of the power system as a whole. At the highest level of control, it is also necessary to consider the economic indicators formed by the energy market. Special devices – controlled inverters – can be effectively used for integration. The most difficult task is choosing a control system for controlled inverters. There are many different control systems such as Proportional-Integral, Deadbeat controllers, etc. The purpose of this paper is to build an information model for controlling distributed power resources. The current control method was used to control active and reactive power. The advantage of current control is resistance to variations in the parameters of the inverter and the external grid, excellent dynamic performance, and higher control accuracy. The proposed approach for building an automatic control system using the Internal model control strategy and taking into account restrictions on the control variable. The advantages of a system with an Internal model control controller compared to a conventional Proportional-Integral controller are the use of a powerful control method based on the object model, the ability to influence the roughness of the system with a separate setting parameter, increased speed with almost complete absence of over-regulation, simplified setup procedure. Such a system is proposed for use in facilities with strict requirements to minimize over-regulation and the speed of working out disturbances and tasks. The PSCAD software app was used to model the work results.