Maria Engel

Maria Engel

Auto-generated profile, based on publicly available information

Maria Engel

Cardiff University Brain Research Imaging Centre (CUBRIC) Cardiff University Cardiff UK

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
MEMaria Engel
Maria Engel
LKLars Kasper
Lars Kasper
BWBertram Wilm
Bertram Wilm
BDBenjamin Dietrich
Benjamin Dietrich
LVLaetitia Vionnet
Laetitia Vionnet
KPKlaas P. Pruessmann
Klaas P. Pruessmann

22 April 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MAMaryam Afzali
Maryam Afzali
LMLars Mueller
Lars Mueller
SCSam Coveney
Sam Coveney
Fabrizio FasanoFabrizio Fasano
Fabrizio Fasano
CEChristopher John Evans
Christopher John Evans
JSJürgen E. Schneider
Jürgen E. Schneider
Purpose: This work reports for the first time on the implementation and application of cardiac diffusion‐weighted MRI on a Connectom MR scanner with a maximum gradient strength of 300 mT/m. It evaluates the benefits of the increased gradient performance for the investigation of the myocardial microstructure.Methods: Cardiac diffusion‐weighted imaging (DWI) experiments were performed on 10 healthy volunteers using a spin‐echo sequence with up to second‐ and third‐order motion compensation ( and ) and , and 1000 (twice the commonly used on clinical scanners). Mean diffusivity (MD), fractional anisotropy (FA), helix angle (HA), and secondary eigenvector angle (E2A) were calculated for b = [100, 450] and b = [100, 1000] for both and .Results: The MD values with are slightly higher than with with for and for . A reduction in MD is observed by increasing the from 450 to 1000 ( for and for ). The difference between FA, E2A, and HA was not significant in different schemes ().Conclusion: This work demonstrates cardiac DWI in vivo with higher b‐value and higher order of motion compensated diffusion gradient waveforms than is commonly used. Increasing the motion compensation order from to and the maximum b‐value from 450 to 1000 affected the MD values but FA and the angular metrics (HA and E2A) remained unchanged. Our work paves the way for cardiac DWI on the next‐generation MR scanners with high‐performance gradient systems.

29 December 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MEMaria Engel
Maria Engel
LMLars Mueller
Lars Mueller
ADAndré Döring
André Döring
MAMaryam Afzali
Maryam Afzali
DJDerek K. Jones
Derek K. Jones
Purpose: The characterization of tissue microstructure using diffusion MRI (dMRI) signals is rapidly evolving, with increasing sophistication of signal representations and microstructure models. However, this progress often requires signals to be acquired with very high b‐values (e.g., b > 30 ms/μm2), along many directions, and using multiple b‐values, leading to long scan times and extremely low SNR in dMRI images. The purpose of this work is to boost the SNR efficiency of dMRI by combining three particularly efficient spatial encoding techniques and utilizing a high‐performance gradient system (Gmax ≤ 300 mT/m) for efficient diffusion encoding.Methods: Spiral readouts, multiband imaging, and sampling on tilted hexagonal grids (T‐Hex) are combined and implemented on a 3T MRI system with ultra‐strong gradients. Image reconstruction is performed through an iterative cg‐SENSE algorithm incorporating static off‐resonance distributions and field dynamics as measured with an NMR field camera. Additionally, T‐Hex multiband is combined with a more conventional EPI‐readout and compared with state‐of‐the‐art blipped‐CAIPIRINHA sampling. The advantage of the proposed approach is furthermore investigated for clinically available gradient performance and diffusion kurtosis imaging.Results: High fidelity in vivo images with b‐values up to 40 ms/μm2 are obtained. The approach provides superior SNR efficiency over other state‐of‐the‐art multiband diffusion readout schemes.Conclusion: The demonstrated gains hold promise for the widespread dissemination of advanced microstructural scans, especially in clinical populations.

4 November 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MMMalwina Molendowska
Malwina Molendowska
LMLars Mueller
Lars Mueller
FFFabrizio Fasano
Fabrizio Fasano
DJDerek K. Jones
Derek K. Jones
CTChantal M. W. Tax
Chantal M. W. Tax
MEMaria Engel
Maria Engel
Purpose: To address key issues of low SNR and image distortions in prostate diffusion MRI (dMRI) by means of using strong gradients, single‐shot spiral readouts and an expanded encoding model for image reconstruction.Methods: Diffusion‐weighted spin echo imaging with EPI and spiral readouts is performed on a whole‐body system equipped with strong gradients (up to 250 mT/m). An expanded encoding model including static off‐resonance, coil sensitivities, and magnetic field dynamics is employed for image reconstruction. The acquisitions are performed on a phantom and in vivo (one healthy volunteer and one patient with prostate cancer). The resulting images are compared to conventional dMRI EPI with navigator‐based image reconstruction and assessed in terms of their congruence, SNR, tissue contrast, and quantitative parameters.Results: Using the expanded encoding model, high‐quality images of the prostate gland are obtained across all b‐values (up to 3 ms/μm2), clearly outperforming the results obtained with conventional image reconstruction. Compared to EPI, spiral imaging provides an SNR gain up to 45% within the gland and even higher in the lesion. In addition, prostate dMRI with single‐shot spirals at submillimeter in‐plane resolution (0.85 mm) is accomplished.Conclusion: The combination of strong gradients and an expanded encoding model enables imaging of the prostate with unprecedented image quality. Replacing the commonly used EPI with spirals provides the inherent benefit of shorter echo times and superior readout efficiency and results in higher SNR, which is in particular relevant for considered applications.

15 November 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
LKLars Kasper
Lars Kasper
MEMaria Engel
Maria Engel
JHJakob Heinzle
Jakob Heinzle
MMMatthias Müller-Schrader
Matthias Müller-Schrader
NGNadine N. Graedel
Nadine N. Graedel
KPKlaas Paul Pruessmann
Klaas Paul Pruessmann
Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging, in particular due to its enhanced average k-space speed and thus high acquisition efficiency. This renders spirals attractive for contemporary fMRI applications that require high spatiotemporal resolution, such as laminar or columnar fMRI. However, in practice, spiral fMRI is typically hampered by its reduced robustness and ensuing blurring artifacts, which arise from imperfections in both static and dynamic magnetic fields. Recently, these limitations have been overcome by the concerted application of an expanded signal model that accounts for such field imperfections, and its inversion by iterative image reconstruction. In the challenging ultra-high field environment of 7 Tesla, where field inhomogeneity effects are aggravated, both multi-shot and single-shot 2D spiral imaging at sub-millimeter resolution was demonstrated with high depiction quality and anatomical congruency. In this work, we further these advances towards a time series application of spiral readouts, namely, single-shot spiral BOLD fMRI at 0.8 mm in-plane resolution. We demonstrate that high-resolution spiral fMRI at 7 T is not only feasible, but delivers both excellent image quality, BOLD sensitivity, and spatial specificity of the activation maps, with little artifactual blurring. Furthermore, we show the versatility of the approach with a combined in/out spiral readout at a more typical resolution (1.5 mm), where the high acquisition efficiency allows to acquire two images per shot for improved sensitivity by echo combination. Highlights: This work reports the first fMRI study at 7T with high-resolution spiral readout gradient waveforms. We achieve spiral fMRI with sub-millimeter resolution (0.8 mm, FOV 230 mm), acquired in a single shot (36 slices in 3.3 s). Spiral images exhibit intrinsic geometric congruency to anatomical scans, and spatially specific activation patterns. Image reconstruction rests on a signal model expanded by measured trajectories and static field maps, inverted by cg-SENSE. We assess generalizability of the approach for spiral in/out readouts, providing two images per shot (1.5 mm resolution).

4 August 2023 in Applied Magnetic Resonance
Verified
Journal Article
Open access
PDF file
SESebastian Endt
Sebastian Endt
MEMaria Engel
Maria Engel
ENEmanuele Naldi
Emanuele Naldi
RARodolfo Assereto
Rodolfo Assereto
MMMalwina Molendowska
Malwina Molendowska
MMMarion I. Menzel
Marion I. Menzel
Multidimensional Magnetic Resonance Imaging (MRI) is a versatile tool for microstructure mapping. We use a diffusion weighted inversion recovery spin echo (DW-IR-SE) sequence with spiral readouts at ultra-strong gradients to acquire a rich diffusion–relaxation data set with sensitivity to myelin water. We reconstruct 1D and 2D spectra with a two-step convex optimization approach and investigate a variety of multidimensional MRI methods, including 1D multi-component relaxometry, 1D multi-component diffusometry, 2D relaxation correlation imaging, and 2D diffusion-relaxation correlation spectroscopic imaging (DR-CSI), in terms of their potential to quantify tissue microstructure, including the myelin water fraction (MWF). We observe a distinct spectral peak that we attribute to myelin water in multi-component T1 relaxometry, T1-T2 correlation, T1-D correlation, and T2-D correlation imaging. Due to lower achievable echo times compared to diffusometry, MWF maps from relaxometry have higher quality. Whilst 1D multi-component T1 data allows much faster myelin mapping, 2D approaches could offer unique insights into tissue microstructure and especially myelin diffusion.