Amir Owrangi

Amir Owrangi

Auto-generated profile, based on publicly available information

Amir Owrangi

Baylor College of Medicine

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
AOAmir M Owrangi
Amir M Owrangi
PGPeter Greer
Peter Greer
CGCarri K Glide-Hurst
Carri K Glide-Hurst
Over the past decade, the application of magnetic resonance imaging (MRI) has increased, and there is growing evidence to suggest that improvements in the accuracy of target delineation in MRI-guided radiation therapy may improve clinical outcomes in a variety of cancer types. However, some considerations should be recognized including patient motion during image acquisition and geometric accuracy of images. Moreover, MR-compatible immobilization devices need to be used when acquiring images in the treatment position while minimizing patient motion during the scan time. Finally, synthetic CT images (i.e. electron density maps) and digitally reconstructed radiograph images should be generated from MRI images for dose calculation and image guidance prior to treatment. A short review of the concepts and techniques that have been developed for implementation of MRI-only workflows in radiation therapy is provided in this document.

1 July 2019 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
SKSamaneh Kazemifar
Samaneh Kazemifar
SMSarah McGuire
Sarah McGuire
RTRobert Timmerman
Robert Timmerman
ZWZabi Wardak
Zabi Wardak
DNDan Nguyen
Dan Nguyen
AOAmir Owrangi
Amir Owrangi

1 December 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
ABAnjali Balagopal
Anjali Balagopal
SKSamaneh Kazemifar
Samaneh Kazemifar
DNDan Nguyen
Dan Nguyen
MLMu-Han Lin
Mu-Han Lin
RHRaquibul Hannan
Raquibul Hannan
SJSteve B Jiang
Steve B Jiang
Accurate segmentation of prostate and surrounding organs at risk is important for prostate cancer radiotherapy treatment planning. We present a fully automated workflow for male pelvic CT image segmentation using deep learning. The architecture consists of a 2D organ volume localization network followed by a 3D segmentation network for volumetric segmentation of prostate, bladder, rectum, and femoral heads. We used a multi-channel 2D U-Net followed by a 3D U-Net with encoding arm modified with aggregated residual networks, known as ResNeXt. The models were trained and tested on a pelvic CT image dataset comprising 136 patients. Test results show that 3D U-Net based segmentation achieves mean (±SD) Dice coefficient values of 90 (±2.0)%, 96 (±3.0)%, 95 (±1.3)%, 95 (±1.5)%, and 84 (±3.7)% for prostate, left femoral head, right femoral head, bladder, and rectum, respectively, using the proposed fully automated segmentation method.

23 July 2018 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
SKSamaneh Kazemifar
Samaneh Kazemifar
ABAnjali Balagopal
Anjali Balagopal
DNDan Nguyen
Dan Nguyen
SMSarah McGuire
Sarah McGuire
RHRaquibul Hannan
Raquibul Hannan
AOAmir M Owrangi
Amir M Owrangi
Inter-and intra-observer variation in delineating regions of interest (ROIs) occurs because of differences in expertise level and preferences of the radiation oncologists. We evaluated the accuracy of a segmentation model using the U-Net structure to delineate the prostate, bladder, and rectum in male pelvic CT images. The dataset used for training and testing the model consisted of raw CT scan images of 85 prostate cancer patients. We designed a 2D U-Net model to directly learn a mapping function that converts a 2D CT grayscale image to its corresponding 2D OAR segmented image. Our network contains blocks of convolution 2D layers with variable kernel sizes, channel number, and activation functions. On the left side of the U-Net model, we used three 3 × 3 convolutions, each followed by a rectified linear unit (ReLu) (activation function), and one max pooling operation. On the right side of the U-Net model, we used a 2 × 2 transposed convolution and two 3 × 3 convolution networks followed by a ReLu activation function. The automatic segmentation using the U-Net generated an average dice similarity coefficient (DC) and standard deviation (SD) of the following: DC ± SD (0.88 ± 0.12), (0.95 ± 0.04), and (0.92 ± 0.06) for the prostate, bladder, and rectum, respectively. Furthermore, the mean of average surface Hausdorff distance (ASHD) and SD were 1.2 ± 0.9 mm, 1.08 ± 0.8 mm, and 0.8 ± 0.6 mm for the prostate, bladder, and rectum, respectively. Our proposed method, which employs the U-Net structure, is highly accurate and reproducible for automated ROI segmentation. This provides a foundation to improve automatic delineation of the boundaries between the target and surrounding normal soft tissues on a standard radiation therapy planning CT scan.

24 February 2021 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
WLWen Li
Wen Li
SKSamaneh Kazemifar
Samaneh Kazemifar
TBTi Bai
Ti Bai
DNDan Nguyen
Dan Nguyen
YWYaochung Weng
Yaochung Weng
SJSteve B Jiang
Steve B Jiang
Background and purpose. Replacing CT imaging with MR imaging for MR-only radiotherapy has sparked the interest of many scientists and is being increasingly adopted in radiation oncology. Although many studies have focused on generating CT images from MR images, only models on data with the same dataset were tested. Therefore, how well the trained model will work for data from different hospitals and MR protocols is still unknown. In this study, we addressed the model generalization problem for the MR-to-CT conversion task. Materials and methods. Brain T2 MR and corresponding CT images were collected from SZSPH (source domain dataset), brain T1-FLAIR, T1-POST MR, and corresponding CT images were collected from The University of Texas Southwestern (UTSW) (target domain dataset). To investigate the model’s generalizability ability, four potential solutions were proposed: source model, target model, combined model, and adapted model. All models were trained using the CycleGAN network. The source model was trained with a source domain dataset from scratch and tested with a target domain dataset. The target model was trained with a target domain dataset and tested with a target domain dataset. The combined model was trained with both source domain and target domain datasets, and tested with the target domain dataset. The adapted model used a transfer learning strategy to train a CycleGAN model with a source domain dataset and retrain the pre-trained model with a target domain dataset. MAE, RMSE, PSNR, and SSIM were used to quantitatively evaluate model performance on a target domain dataset. Results. The adapted model achieved best quantitative results of 74.56 ± 8.61, 193.18 ± 17.98, 28.30 ± 0.83, and 0.84 ± 0.01 for MAE, RMSE, PSNR, and SSIM using the T1-FLAIR dataset and 74.89 ± 15.64, 195.73 ± 31.29, 27.72 ± 1.43, and 0.83 ± 0.04 for MAE, RMSE, PSNR, and SSIM using the T1-POST dataset. The source model had the poorest performance. Conclusions. This work indicates high generalization ability to generate synthetic CT images from small training datasets of MR images using pre-trained CycleGAN. The quantitative results of the test data, including different scanning protocols and different acquisition centers, indicated the proof of this concept.

24 January 2012 in Medical Physics
Verified
Journal Article
Closed access
JAJoseph Awad
Joseph Awad
AOAmir Owrangi
Amir Owrangi
LVLauren Villemaire
Lauren Villemaire
EOElaine O'RIordan
Elaine O'RIordan
GPGrace Parraga
Grace Parraga
Aaron FensterAaron Fenster
Aaron Fenster