Ziqian Zeng

Ziqian Zeng

Auto-generated profile, based on publicly available information

Ziqian Zeng

Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114 USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2024 in Science Advances
Verified
Journal Article
Open access
NLNichaluk Leartprapun
Nichaluk Leartprapun
ZZZiqian Zeng
Ziqian Zeng
ZHZeinab Hajjarian
Zeinab Hajjarian
VBVeerle Bossuyt
Veerle Bossuyt
SNSeemantini K. Nadkarni
Seemantini K. Nadkarni
Viscoelastic transformation of tissue drives aberrant cellular functions and is an early biomarker of disease pathogenesis. Tissues scale a range of viscoelastic moduli, from biofluids to bone. Moreover, viscoelastic behavior is governed by the frequency at which tissue is probed, yielding distinct viscous and elastic responses modulated over a wide frequency band. Existing tools do not quantify wideband viscoelastic spectra in tissues, leaving a vast knowledge gap. We present wideband laser speckle rheological microscopy (WB-SHEAR) that reveals elastic and viscous response over sub-megahertz frequencies previously not investigated in tissue. WB-SHEAR uses an optical, noncontact approach to quantify wideband viscoelastic spectra in specimens spanning a range of moduli from low-viscosity fibrin to highly elastic bone. Via laser scanning, micromechanical imaging is enabled to access wideband viscoelastic spectra in heterogeneous tumor specimens with high spatial resolution (25 micrometers). The ability to interrogate the viscoelastic landscape of diverse biospecimens could transform our understanding of mechanobiological processes in various diseases.

10 October 2022 in ChemMedChem
Verified
Journal Article
Open access
TCTanmaye Nallan Chakravarthula
Tanmaye Nallan Chakravarthula
ZZZiqian Zeng
Ziqian Zeng
NANathan J. J Alves
Nathan J. J Alves
There is an emerging interest in utilizing synthetic multivalent inhibitors that comprise of multiple inhibitor moieties linked on a common scaffold to achieve strong and selective enzyme inhibition. As multivalent inhibition is impacted by valency and linker length, in this study, we explore the effect of multivalent benzamidine inhibitors of varying valency and linker length on plasmin inhibition. Plasmin is an endogenous enzyme responsible for digesting fibrin present in blood clots. Monovalent plasmin(ogen) inhibitors are utilized clinically to treat hyperfibrinolysis‐associated bleeding events. Benzamidine is a reversible inhibitor that binds to plasmin's active site. Herein, multivalent benzamidine inhibitors of varying valencies (mono‐, bi‐ and tri‐valent) and linker lengths (∼1–12 nm) were synthesized to systematically study their effect on plasmin inhibition. Inhibition assays were performed using a plasmin substrate (S‐2251) to determine inhibition constants (Ki). Pentamidine (shortest bivalent) and Tri‐AMB (shortest trivalent) were the strongest inhibitors with Ki values of 2.1±0.8 and 3.9±1.7 μM, respectively. Overall, increasing valency and decreasing linker length, increases effective local concentration of the inhibitor and therefore, resulted in stronger inhibition of plasmin via statistical rebinding. This study aids in the design of multivalent inhibitors that can achieve desired enzyme inhibition by means of modulating valency and linker length.

26 September 2025 in Science Advances
Verified
Journal Article
Open access
ZHZeinab Hajjarian
Zeinab Hajjarian
NLNichaluk Leartprapun
Nichaluk Leartprapun
ZZZiqian Zeng
Ziqian Zeng
SNSeemantini K. Nadkarni
Seemantini K. Nadkarni
Tissues and biomaterials are composed of particles, including cells, nuclei, organelles, protein aggregates, lipid vesicles, and fibers. The size distribution of tissue particles and granularities is altered in various pathologies. These granularities span a wide range from nano- to micrometer scale, posing a unique challenge in quantifying the continuum of particles sizes in intact tissue. We introduce laser Speckle PARticle SizEr (SPARSE), a noncontact optical technique that enables particle sizing over 10 nanometer–to–10 micrometer range, through analyzing the spatiotemporal attributes of polarized laser speckle, back-scattered from biofluids and tissues. We demonstrate that SPARSE effectively quantifies the average particle sizes in milk, blood, and intact tissue without a prior knowledge of particles’ refractive indices or concentrations. Through beam scanning, particle size distribution is mapped in benign and malignant breast tissues with high resolution (~100 micrometer), mirroring histopathological microstructures. By enabling particle sizing in intact biomaterials and tissues, SPARSE holds broad potential for applications across nanomedicine, diagnostics, and biotechnology.

19 November 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
ZZZiqian Zeng
Ziqian Zeng
LXLinxiao Xia
Linxiao Xia
YLYalei Liu
Yalei Liu
JWJianjun Wu
Jianjun Wu
QCQi Chen
Qi Chen
ZTZhifeng Tang
Zhifeng Tang
Wideband laser speckle rheological microscopy (WBSHEAR) enables frequency-resolved characterization of blood viscoelasticity, yet its potential for quantitative blood-composition sensing remains largely unexplored. This study investigated whether different representations of laser-speckle dynamics could support task-specific prediction of blood constituents through machine learning. Four signal representations, including temporal autocorrelation (G2), local scaling exponent (Alpha), viscoelastic spectrum (Spectrum), and manually extracted spectral descriptors (Manual), were evaluated individually and in combination. Using controlled porcine blood suspensions, 378 task-specific measurement records were collected across four compositional perturbations: red blood cell (RBC) fraction, Intralipid, fibrinogen, and albumin. Seven representation pathways and six regression models were systematically compared using acquisition-provenance-grouped nested cross-validation. Record-level out-of-fold predictions achieved R2 values of 0.802, 0.956, 0.949, and 0.936 for RBC fraction, Intralipid, fibrinogen, and albumin, respectively. The most frequently selected representations differed across tasks: Alpha + Spectrum for RBC fraction (75.0% of outer folds), Spectrum for Intralipid (55.6%), and G2 for fibrinogen (91.7%) and albumin (92.3%). These findings demonstrate that different representations of the same laser-speckle measurements retain distinct predictive information associated with blood-composition changes. Task-adaptive representation selection therefore provides a promising computational framework for extending WBSHEAR beyond viscoelastic characterization toward quantitative blood-composition sensing.