Terry J. Harvey

Terry J. Harvey

Auto-generated profile, based on publicly available information

Terry J. Harvey

National Centre for Advanced Tribology at Southampton (nCATS), Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
DXDichu Xu
Dichu Xu
THTerence Harvey
Terence Harvey
EBEider Begiristain
Eider Begiristain
CDCristina Domínguez
Cristina Domínguez
LSLaura Sánchez-Abella
Laura Sánchez-Abella
RCRichard B. Cook
Richard B. Cook
The measurement of the elastic modulus of soft biomaterials via nanoindentation relies on the accurate determination of the zero-point of the tip-sample interaction on which the depth of penetration into the sample is based. Non-cantilever based nanoindentation systems were originally designed for hard materials, and therefore monitoring the zero-point contact presents a significant challenge for the characterisation of very soft biomaterials. This study investigates the ability of non-cantilever based nanoindentation to differentiate between hydrogels with elastic moduli on the order of single kiloPascals (kPa) using a bespoke soft contact protocol and low flexural stiffness of instrument. Polyethylene glycol (PEG) hydrogels were fabricated as a model system with a range of elastic moduli by varying the polymer concentration and degree of crosslinking. Elastic modulus values were calculated using the Oliver-Pharr method, Hertzian contact model, as well as a viscoelastic model to account for the time-dependent behaviour of the gels. The stiffness measurements were validated by measuring cantilever beams with the equivalent flexural stiffness to that of the PEG hydrogels being tested. The results demonstrated a high repeatability of the measurements, enabling differentiation between hydrogels with elastic moduli in the single kPa to hundreds of kPa range.

3 February 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BZBahareh Zaghari
Bahareh Zaghari
Alex WeddellAlex Weddell
Alex Weddell
KEKamran Esmaeili
Kamran Esmaeili
IBImran Bashir
Imran Bashir
THTerry J. Harvey
Terry J. Harvey
LWLing Wang
Ling Wang
Integrated health monitoring is beneficial but due to reliability, weight, size, wiring and other constraints, the incorporation of instrumentation onto aircraft propulsion systems is limited. Conventional wired sensing systems are not always feasible due to size, weight constraints, and issues associated with cable routing. This paper presents an integrated and self-powered wireless system for high temperature (above 125°C) environments powered by a thermoelectric generator for bearing condition monitoring. Thermoelectric generator with internal oil cooling chamber is proposed to achieve higher energy output for small temperature gradient recorded in the jet engine in comparison with other thermoelectric generators with heat sinks. The experimental results demonstrate that, under a simulated engine environment, the thermoelectric generator can provide sufficient energy for a wireless sensing system to collect environmental data every 46 s, and transmit every 260 s, during the critical take-off phase of flight and part of cruise.

5 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KEKamran Esmaeili
Kamran Esmaeili
LWLing Wang
Ling Wang
THTerry J. Harvey
Terry J. Harvey
NWNeil White
Neil White
WHWalter Holweger
Walter Holweger
The reliability of rolling element bearings has been substantially undermined by the presence of parasitic and stray currents. Electrical discharges can occur between the raceway and the rolling elements and it has been previously shown that these discharges at relatively high current density levels can result in fluting and corrugation damages. Recent publications have shown that for a bearing operating at specific mechanical conditions (load, temperature, speed, and slip), electrical discharges at low current densities (<1 mA/mm2) may substantially reduce bearing life due to the formation of white etching cracks (WECs) in bearing components, often in junction with lubricants. To date, limited studies have been conducted to understand the electrical discharges at relatively low current densities (<1 mA/mm2), partially due to the lack of robust techniques for in-situ quantification of discharges. This study, using voltage measurement and electrostatic sensors, investigates discharges in an oil-lubricated steel-steel rolling contact on a TE74 twin-roller machine under a wide range of electrical and mechanical conditions. The results show that the discharges events between the rollers are influenced by temperature, load, and speed due to changes in the lubricant film thickness and contact area, and the sensors are effective in detecting, characterizing and quantifying the discharges. Hence, these sensors can be effectively used to study the influence of discharges on WEC formation.

1 May 2009 in Vibrational Spectroscopy
Verified
Journal Article
Open access
EGE. Gazi
E. Gazi
THT.J. Harvey
T.J. Harvey
MBMichael David Brown
Michael David Brown
NLNicholas P Lockyer
Nicholas P Lockyer
PGPeter Gardner
Peter Gardner
NCNoel Clarke
Noel Clarke

21 August 2020 in RSC Advances
Verified
Journal Article
Open access
PDF file
ANAdrian Nightingale
Adrian Nightingale
SHSammer Ul Hassan
Sammer Ul Hassan
KMKyriacos Makris
Kyriacos Makris
WBWahida T. Bhuiyan
Wahida T. Bhuiyan
THTerry J. Harvey
Terry J. Harvey
XNXize Niu
Xize Niu
We present a widely accessible method for fabricating monolithic fluoropolymer microfluidic chips, which allows droplet absorbance measurement over multi-month periods.

4 October 2018 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Closed access
PDF file
CBCharles Burson-Thomas
Charles Burson-Thomas
RWRichard Wellman
Richard Wellman
THTerry J. Harvey
Terry J. Harvey
Robert James WoodRobert James Wood
Robert James Wood
When modeling a droplet impingement, it is reasonable to assume a surface is flat when the radius of curvature of the surface is significantly larger than the droplet radius. In other contexts where water droplet erosion (WDE) has been investigated, the typical droplet size has either been sufficiently small, or the radius of curvature of the surface sufficiently large, that it has been sensible to make this assumption. The equations describing the kinematics of an impinging water droplet on a flat surface were reformulated for a curved surface. The results suggest the relatively similar radii of curvature, of the leading-edge of a fan blade and the impinging water droplet, will significantly affect the application of the initial high-pressures, along with the onset of lateral outflow jetting. Jetting is predicted to commence substantially sooner and not in unison along the contact periphery, leading to an asymmetric flow stage. This is likely to have significant implications for the WDE that occurs, and thus, the engineering approaches to minimize the WDE of fan blades.