When modeling a droplet impingement, it is reasonable to assume a surface is flat when the radius of curvature of the surface is significantly larger than the droplet radius. In other contexts where water droplet erosion (WDE) has been investigated, the typical droplet size has either been sufficiently small, or the radius of curvature of the surface sufficiently large, that it has been sensible to make this assumption. The equations describing the kinematics of an impinging water droplet on a flat surface were reformulated for a curved surface. The results suggest the relatively similar radii of curvature, of the leading-edge of a fan blade and the impinging water droplet, will significantly affect the application of the initial high-pressures, along with the onset of lateral outflow jetting. Jetting is predicted to commence substantially sooner and not in unison along the contact periphery, leading to an asymmetric flow stage. This is likely to have significant implications for the WDE that occurs, and thus, the engineering approaches to minimize the WDE of fan blades.
The survivorship of cementless orthopaedic implants may be related to their initial stability; insufficient press-fit can lead to excessive micromotion between the implant and bone, joint pain, and surgical revision. However, too much interference between implant and bone can produce excessive strains and damage the bone, which also compromises stability. An understanding of the nature and mechanisms of strain generation during implantation would therefore be valuable. Previous measurements of implantation strain have been limited to local discrete or surface measurements. In this work, we devise a Digital Volume Correlation (DVC) methodology to measure the implantation strain throughout the volume. A simplified implant model was implanted into analogue bone media using a customised loading rig, and a micro-CT protocol optimised to minimise artefacts due to the presence of the implant. The measured strains were interpreted by FE modelling of the displacement-controlled implantation, using a bilinear elastoplastic constitutive model for the analogue bone. The coefficient of friction between the implant and bone was determined using the experimental measurements of the reaction force. Large strains at the interface between the analogue bone and implant produced localised deterioration of the correlation coefficient, compromising the ability to measure strains in this region. Following correlation coefficient thresholding (removing strains with a coefficient less than 0.9), the observed strain patterns were similar between the DVC and FE. However, the magnitude of FE strains was approximately double those measured experimentally. This difference suggests the need for improvements in the interface failure model, for example, to account for localised buckling of the cellular analogue bone structure. A further recommendation from this work is that future DVC experiments involving similar geometries and structures should employ a subvolume size of 0.97 mm as a starting point.
23 November 2022 in Journal of Medical Internet Research
Repeated high-speed liquid impingement on solid surfaces results in erosion that can have undesirable consequences. In recent years, the capacity of model predictions has exceeded the experimental measurements of an impingement; this work closes the gap. Using the grid method, tens of thousands of individual measurements of surface displacement were taken of the response of a polymethylmethacrylate test specimen to the impingement of a high-speed ( ) curved-fronted water jet. The full-field measurements were taken at a rate of 5 MHz and interpreted using two models based on differing sets of assumptions. The results support the current qualitative description of a high-speed impingement. However, the widespread assumption of a rigid solid surface in existing analysis and modelling was found to be inaccurate: only the model that recognized the effect of the compliance of the solid surface was successful in predicting the measured temporal and spatial variation in displacement and acceleration. This model predicted that the energy absorbed by the solid surface was less than 0.3% of the total kinetic energy of the equivalent droplet impingement.