13 June 2022 in IEEE Access
Geomagnetically Induced Currents (GICs) are induced after a complex interaction between the sun and earth’s magnetic field. GICs may cripple power systems leading to voltage collapse and a drop in power quality. While the commonly-used dc model for GICs is valid for steady-state analyses of power systems and transformer responses, GICs must be represented with their continuously varying magnitudes and frequency components to understand the dynamic power system’s response to solar storms. In this paper, we used measured GIC data from the 2003 Halloween storm to compare several signal processing techniques. The Fast Fourier Transform (FFT) with a fixed window size, Short-Time Fourier Transform (STFT) with a variable window size, wavelet transform, and Particle-Swarm Optimization (PSO) methods were used to identify the GIC frequency characteristics. To understand the effects of these GIC characteristics on voltage stability, a multi-machine network was modelled on a digital real-time simulator (OPAL-RT). The results reveal the limitations of fixed window FFT in capturing the dominant high-frequency GIC bandwidth arising during peak solar activity. Wavelet and STFT are recommended for GIC data analysis as they provide time-frequency localization. High-frequency GICs during sudden storm commencements and pulsation activity are more of a concern for voltage stability than lower frequency components. Novel results from this study suggest that limiting contingency analysis to only high magnitudes of dc/GIC does not cater for the underlining GIC dynamics. In addition to magnitude thresholds, contingency analysis should incorporate GIC characteristics such as frequency which affect voltage dynamics and thus power system stability.
29 March 2022 in IEEE Transactions on Power Delivery
Geomagneticallyinduced current (GIC) studies usually focus on transformer response to dc but seldom analyze generator excitation systems. A GIC is driven by an electric field which is induced by a very low-frequency geomagnetic field. It is widely acceptable to model GICs with dc, mostly suitable for static voltage stability analysis, but this does not adequately characterize a power system's dynamic response. Considering this, we studied a multi-machine power system on an OPAL-RT digital real-time simulator (DRTS)-MATLAB/Simulink system. We used real GIC measurement data from high and mid-latitude regions. Wavelet analysis related the frequency components of the GIC to the power system's response. A dynamic generator model with excitation voltage control modelled the source. Our main finding is that excitation system control contributes to reducing the voltage drop caused by increased var demand in saturated transformers with GICs. Measured GICs revealed non-negligible short-term dynamics affecting bus voltages that are not captured with dc-modelling assumptions, yet they are important for voltage stability analysis. This study implies that excitation control creates a buffer for high GICs to flow without violating the grid codes for minimum operating voltages and this paper demonstrates the optimization of this novel approach.
27 October 2023 in Scientific African
It is well understood that geomagnetically induced currents (GICs) flow through the grounded neutrals of wye-connected transformers, generating harmonic currents that flow along frequency-dependent transmission lines. Harmonic currents affect protection systems and cause harmonic voltage drops that disturb power system voltage stability. In the literature, GICs are modelled as dc-currents for harmonic analysis. However, GICs are multi-frequency currents having both positive and negative polarities. Therefore, a representative harmonic analysis of power systems is only possible when GICs are modelled as multi-frequency AC currents. In this paper, the authors subject a multi-machine power system model to real GICs from the 2003 Halloween storm. Representative time intervals within the storm were selected, and a harmonic analysis of transmission line and generator stator currents was carried out. The results showed that the harmonic spectrum of currents fluctuated with a real GIC instead of reaching a steady state with a DC model for GIC. Moreover, harmonics induced on generator windings increase the risk of dynamic voltage and power system instability. The results confirm the susceptibility of power system generators to GICs and validate the use of synthetic GIC for modelling the effect of power system stability.