David Oyedokun

Prof. David Oyedokun


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020
Verified
Conference Paper
Closed access
DODavid Oyedokun
David Oyedokun
MHMichael Heyns
Michael Heyns
PCPierre Cilliers
Pierre Cilliers
CGCt Gaunt
Ct Gaunt
Geomagnetically induced currents (GICs) in power systems are conventionally modelled as direct currents, based on their commonly described quasi-DC nature. For more representative power system dynamic response modelling, it is necessary to model GICs using low-frequency AC. After analysing spectra of geomagnetic field measurements and GICs in several power systems, preliminary results indicate that the GIC spectra depend on the magnitude and frequency spectrum of the geomagnetic disturbance, the earth conductivity and the electrical characteristics of the network. In this paper, analysis based on measured GIC power spectra suggests that the dominant frequencies to use in GIC modelling and simulation are typically below 50 mHz. The associated error introduced by only using these frequencies is also quantified. The results have implications for modelling the geoelectric fields inducing GICs, dynamic models of power system response and the need for GICs and their associated driving fields to be measured at intervals not exceeding 10 s.

29 February 2016 in Space Weather
Verified
Journal Article
Open access
PDF file
EMElectdom Matandirotya
Electdom Matandirotya
PCPierre Cilliers
Pierre Cilliers
RZRobert R Van Zyl
Robert R Van Zyl
DODavid Oyedokun
David Oyedokun
JVJean de Villiers
Jean de Villiers
Geomagnetically induced currents (GICs) in conductors connected to the Earth are driven by an electric field produced by a time‐varying magnetic field linked to magnetospheric‐ionospheric current perturbations during geomagnetic storms. The GIC measurements are traditionally done on the neutral‐to‐ground connections of power transformers. A method of inferring the characteristics of GIC in power lines using differential magnetic field measurements is presented. Measurements of the GIC in the power lines connected to a particular power transformer are valuable in the verification of the modeling of GIC in the power transmission network. The differential magnetometer method (DMM) is an indirect method used to estimate the GIC in a power line. With the DMM, low‐frequency GIC in the power line is estimated from the difference between magnetic field recordings made directly underneath the power line and at some distance away, where the magnetic field of the GIC in the transmission line has negligible effect. Results of the first application of the DMM to two selected sites of the Southern African power transmission network are presented. The results show that good quality GIC measurements are achieved through the DMM using Commercially‐Off‐The‐Shelf magnetometers.

1 June 2017
Verified
Conference Paper
Closed access
OAOluwagbenga Apata
Oluwagbenga Apata
DODavid Oyedokun
David Oyedokun
This paper discusses the currently used generator systems in wind energy conversion systems and some of the newer concepts with their technical features. The Brushless doubly fed induction generator, Brushless doubly fed reluctance generator and the Switched reluctance generator are viable alternatives for wind power applications. This paper also highlights the hybrid wind generator solutions which is an emerging trend in hybrid renewable energy solutions. Using the appropriate control techniques, these generator technologies unlike the conventional wind turbine generator can produce constant wind power irrespective of the changes in velocity of wind speed. This has tremendous application in Africa as the installed capacity increases and the need to provide remote communities with electricity remains paramount. The merits and demerits of the various technologies are uniquely grouped in a novel way to aid decision making based on available resources.

1 September 2009
Verified
Conference Paper
Closed access
DODavid Oyedokun
David Oyedokun
KFKomla Folly
Komla Folly
SCS.P. Chowdhury
S.P. Chowdhury
This paper deals with the effect of DC faults on the transient stability of a multi-machine power system with two transmission line configurations; HVDC and a hybrid HVAC-HVDC transmission line. The faults are located at the DC terminals of the HVDC converter station. In order to carry out this study, two case studies are presented. In the first case study a double HVDC transmission line is used to transmit 2000 MW to an area of the power system called Pookland which has a total load demand of 2440 MW. In case two, a parallel hybrid HVAC-HVDC transmission line is used to transmit the same amount of power to Pookland. In both cases, the impact of a short term converter DC fault on the transient stability of the entire system was investigated. This was done by studying the response of the rotor angle of G2 in Pookland, G3 in the Bing Coal plant and the voltage profile at the terminals of the generators to the DC fault at the HVDC converter station. Amongst other results, it was established that in case 1 which has a double HVDC transmission line, the rectifier side (in the Bing coal plant) has less rotor angle oscillations when compared to the inverter side (in Pookland), but the rectifier side took longer than the inverter side for the rotor angle of the generators to stabilize. In case 2, the voltage at G2 in Pookland took six times the amount of time it took G3 in the Bing coal plant to stabilize while the voltage in the Bing Coal plant dipped by 0.35 pu (smaller than case 1 which dipped by 0.4 pu). In conclusion, the converter DC fault had a smaller impact on the transient stability of the multi-machine power system when the hybrid HVAC-HVDC transmission line was adopted.

13 June 2022 in IEEE Access
Verified
Journal Article
Open access
PJPitambar Jankee
Pitambar Jankee
DODavid Oyedokun
David Oyedokun
MSMaysam Soltanian
Maysam Soltanian
HCHilary K. Chisepo
Hilary K. Chisepo
MHMichael Heyns
Michael Heyns
Geomagnetically Induced Currents (GICs) are induced after a complex interaction between the sun and earth’s magnetic field. GICs may cripple power systems leading to voltage collapse and a drop in power quality. While the commonly-used dc model for GICs is valid for steady-state analyses of power systems and transformer responses, GICs must be represented with their continuously varying magnitudes and frequency components to understand the dynamic power system’s response to solar storms. In this paper, we used measured GIC data from the 2003 Halloween storm to compare several signal processing techniques. The Fast Fourier Transform (FFT) with a fixed window size, Short-Time Fourier Transform (STFT) with a variable window size, wavelet transform, and Particle-Swarm Optimization (PSO) methods were used to identify the GIC frequency characteristics. To understand the effects of these GIC characteristics on voltage stability, a multi-machine network was modelled on a digital real-time simulator (OPAL-RT). The results reveal the limitations of fixed window FFT in capturing the dominant high-frequency GIC bandwidth arising during peak solar activity. Wavelet and STFT are recommended for GIC data analysis as they provide time-frequency localization. High-frequency GICs during sudden storm commencements and pulsation activity are more of a concern for voltage stability than lower frequency components. Novel results from this study suggest that limiting contingency analysis to only high magnitudes of dc/GIC does not cater for the underlining GIC dynamics. In addition to magnitude thresholds, contingency analysis should incorporate GIC characteristics such as frequency which affect voltage dynamics and thus power system stability.

21 November 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Oludamilare Bode AdewuyiOludamilare Bode Adewuyi
Oludamilare Bode Adewuyi
KFKomla Folly
Komla Folly
DODavid Oyedokun
David Oyedokun
EOEmmanuel Idowu Ogunwole
Emmanuel Idowu Ogunwole
In the current era of e-mobility and for the planning of sustainable grid infrastructures, developing new efficient tools for real-time grid performance monitoring is essential. Thus, this paper presents the prediction of the voltage stability margin (VSM) of power systems by the critical boundary index (CBI) approach using the machine learning technique. Prediction models are based on an adaptive neuro-fuzzy inference system (ANFIS) and its enhanced model with particle swarm optimization (PSO). Standalone ANFIS and PSO-ANFIS models are implemented using the fuzzy ‘c-means’ clustering method (FCM) to predict the expected values of CBI as a veritable tool for measuring the VSM of power systems under different loading conditions. Six vital power system parameters, including the transmission line and bus parameters, the power injection, and the system voltage derived from load flow analysis, are used as the ANFIS model implementation input. The performances of the two ANFIS models on the standard IEEE 30-bus and the Nigerian 28-bus systems are evaluated using error and regression analysis metrics. The performance metrics are the root mean square error (RMSE), mean absolute percentage error (MAPE), and Pearson correlation coefficient (R) analyses. For the IEEE 30-bus system, RMSE is estimated to be 0.5833 for standalone ANFIS and 0.1795 for PSO-ANFIS; MAPE is estimated to be 13.6002% for ANFIS and 5.5876% for PSO-ANFIS; and R is estimated to be 0.9518 and 0.9829 for ANFIS and PSO-ANFIS, respectively. For the NIGERIAN 28-bus system, the RMSE values for ANFIS and PSO-ANFIS are 5.5024 and 2.3247, respectively; MAPE is 19.9504% and 8.1705% for both ANFIS and PSO-ANFIS variants, respectively, and the R is estimated to be 0.9277 for ANFIS and 0.9519 for ANFIS-PSO, respectively. Thus, the PSO-ANFIS model shows a superior performance for both test cases, as indicated by the percentage reduction in prediction error, although at the cost of a higher simulation time.