Hafsa Qamar

Hafsa Qamar

Auto-generated profile, based on publicly available information

Hafsa Qamar

Syed Babar Ali School of Science and Engineering, Lahore University of Management Sciences, Lahore, Pakistan

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DWDeliang Wu
Deliang Wu
HQHafsa Qamar
Hafsa Qamar
HQHaleema Qamar
Haleema Qamar
RARajapandian Ayyanar
Rajapandian Ayyanar
A bus-clamping space vector pulsewidth modulation (PWM) called 240°-clamped PWM (240CPWM) is analyzed for three-phase converters that have a cascaded connection of a dc-dc stage and a dc-ac stage. A direct application of the proposed concept is electric vehicle (EV) traction inverters that employ a dc-dc stage to interface a relatively low-voltage battery to a high-voltage motor. The 240CPWM method has the major advantages of clamping a phase to the positive or negative rail for 240° in a fundamental period, clamping of two phases simultaneously at any given instant, and use of only active states, completely eliminating the use of zero states. These characteristics lead to more than seven times reduction in switching losses of the inverter at unity power factor compared to CSVPWM, comparable or better total harmonic distortion (THD) performance, significant reduction in common-mode voltage and high efficiency. The THD of the line current is analyzed using the notion of stator flux ripple and compared with conventional and discontinuous PWM methods. The switching loss characteristics under different power factor conditions are discussed. Experimental results from a 10-kW hardware prototype are presented. The full load efficiency with the proposed 240CPWM for the dc-ac stage exceeds 99% even with Si insulated-gate bipolar transistors (IGBTs).

30 August 2021 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
HQHafsa Qamar
Hafsa Qamar
HQHaleema Qamar
Haleema Qamar
RARajapandian Ayyanar
Rajapandian Ayyanar
High switching frequency inverters in hybrid electric vehicle/electric vehicle (HEV/EV) drivetrains present problems such as common mode voltage (CMV) and leakage current that have negative impacts on the performance of the drivetrain. Various reduced CMV PWM (RCMV-PWM) methods have been introduced in the literature that reduces the CMV but typically at the expense of increased total harmonic distortion (THD) and switching loss simultaneously. In this article, a low-loss PWM method called 240°-clamped space vector PWM (240CPWM) is discussed in terms of its CMV and leakage current characteristics. It is analytically shown that 240CPWM reduces the peak CMV and the number of CMV pulses in a switching period by 66.7% each, and RMS CMV by 21%, while simultaneously reducing the switching loss by 85%, and achieving similar THD at maximum speed (and lower THD at other speeds) as compared to conventional space vector PWM (CSVPWM). Detailed analysis of CMV and leakage current is presented for 240CPWM and compared with CSVPWM and discontinuous PWM (DPWM1) with constant and variable dc-link voltage control. Experimental results from a 10-kW hardware prototype are presented that conform to the analytical discussions and validate the superior performance of 240CPWM.

19 July 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
HQHaleema Qamar
Haleema Qamar
HQHafsa Qamar
Hafsa Qamar
NKNikhil Korada
Nikhil Korada
RARajapandian Ayyanar
Rajapandian Ayyanar
This paper evaluates the performance of relatively new PWM method i.e., 240$^\circ$-Clamped Space Vector PWM (240CPWM) in three phase grid-connected photovoltaic (PV) converters under various grid voltage conditions. 240CPWM is a minimum switching loss PWM method that reduces the switching loss by 85% at unity power factor and has better THD as compared to conventional space vector PWM (CSVPWM). A unique six-pulse dynamically varying DC link voltage is required for 240CPWM. Typically, a three-phase grid-connected PV system consists of a DC-DC stage followed by a DC-AC stage. In this work, DC-DC stage is operated in close loop control to shape the dynamic DC link voltage required for 240CPWM. DC-AC stage is operated in current control mode using proportional integral (PI) along with harmonic compensator (HC) to ensure sinusoidal grid currents along with maximum power point tracking. The modulation index of DC-AC stage is uncontrolled and fixed at the maximum value, and the primary control mechanism is changing the magnitude, phase and waveshape of the DC link voltage. The coordinated control of DC-DC and DC-AC stage is ensured for better dynamic performance and grid support functions. Finally, the performance of grid connected PV converter with 240CPWM is validated using a three-phase 3 kW, 208 V hardware prototype under non-unity power factors, voltage unbalance and voltage sag/swell conditions for the first time. The implemented control with 240CPWM achieves smooth operation under non-unity power factor and grid voltage disturbance conditions with THD as low as 3.5% and peak combined efficiency of DC-DC and DC-AC stage as 96.4%.

28 February 2022 in IEEE Open Journal of Power Electronics
Verified
Journal Article
Open access
HQHaleema Qamar
Haleema Qamar
HQHafsa Qamar
Hafsa Qamar
NKNikhil Korada
Nikhil Korada
RARajapandian Ayyanar
Rajapandian Ayyanar
Transformerless voltage source inverters (VSIs) are one of the popular topologies for photovoltaic (PV) grid-connected applications due to the lowest component count and simple design. Because of the absence of galvanic isolation in such systems, problem of electromagnetic interference (EMI) due to high leakage current is highly pronounced. Recently various reduced common mode voltage (CMV) PWM (RCMV-PWM) methods which address these issues of CMV, and leakage current have been proposed. These schemes typically function at the expense of increased total harmonic distortion (THD), higher switching loss, high DC link current stress along with limited modulation index range. In this work, 240 $^\circ$ clamped PWM (240CPWM) is selected as an ideal candidate for grid connected VSIs in terms of all round performance of switching loss, THD, DC link current stress, CMV and leakage current. 240CPWM is a relatively new space vector based PWM method which can attain much superior performance by avoiding the zero states. After a brief overview of the 240CPWM concept, the paper provides a detailed comparison of 240CPWM with conventional space vector PWM (CSVPWM) and discontinuous PWM (DPWM1) methods in terms of each of the above metrics. A 3-phase 208 V 3 kW silicon IGBT based hardware prototype is built to validate the performance of 240CPWM and compared with other popular schemes under grid-connected mode. Experimental results show a 66.7% reduction in the peak CMV and 50% reduction in leakage current with the proposed scheme as compared to CSVPWM. Also, THD, DC link current stress and inverter switching loss are greatly reduced as an added advantage using the proposed method. A new, combined performance index is proposed to compare the performance of different PWM schemes, and it is shown that the 240CPWM achieves the best value for this index among the PWM methods studied.

12 June 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HQHafsa Qamar
Hafsa Qamar
HQHaleema Qamar
Haleema Qamar
RARajapandian Ayyanar
Rajapandian Ayyanar
240°-Clamped Pulse Width Modulation (240CPWM) is the lowest switching-loss PWM for cascaded architectures consisting of a DC-DC stage followed by a DC-AC stage. At unity power factor, 240CPWM reduces switching losses in the DC-AC stage by 85% compared to conventional Space Vector PWM (CSVPWM). This method requires a six-pulse, dynamically varying DC link voltage, which is shaped by the front-end DC-DC converter, making it suitable for two-stage architectures. However, an extra power stage (DC-DC converter) in cascaded architecture reduces overall efficiency in electric and hybrid electric vehicle (EV/HEV) powertrains compared to single-stage topologies. To address this, we propose a high-efficiency powertrain that minimizes losses in both stages simultaneously. The DC-DC stage employs a soft-switching technique while the DC-AC stage uses 240CPWM. The coordinated control of both the stages is implemented for seamless operation. The detailed loss breakdown of both the DC-DC and DC-AC stages is presented analytically and then verified experimentally. Experimental results demonstrate that the proposed architecture achieves an overall efficiency of 96.16% for the DC-DC and DC-AC stages combined, compared to 92.65% for a cascaded architecture with a hard-switched DC-DC stage followed by a DC-AC stage with CSVPWM, demonstrating 3.51% improvement in overall powertrain efficiency. This efficiency improvement is achieved while maintaining a similar total harmonic distortion (THD) of around 5% in the line currents compared to the conventional architecture.

25 May 2023 in IEEE Open Journal of Power Electronics
Verified
Journal Article
Open access
HQHafsa Qamar
Hafsa Qamar
HQHaleema Qamar
Haleema Qamar
NKNikhil Korada
Nikhil Korada
RARajapandian Ayyanar
Rajapandian Ayyanar
240 $^\circ$ -Clamped Space Vector PWM (240CPWM) is a lowest switching loss PWM method in cascaded architecture of DC-DC stage followed by DC-AC stage that reduces the switching loss by 85% in the DC-AC stage at unity power factor as compared to conventional space vector PWM (CSVPWM). 240CPWM requires unique six-pulse dynamically varying DC link voltage instead of constant DC link voltage which introduces low frequency harmonics predominantly around six times the fundamental frequency ( $6f_{1}$ ). These low frequency harmonics distort the input DC current and AC line currents. Moreover, they change the operating point of maximum power point tracking (MPPT), reducing the efficiency of grid-connected Photovoltaic (PV) converter. In this paper, three topologies are proposed to reduce the low frequency ripple in input DC current and AC line currents in three-phase grid-connected PV systems with 240CPWM. A three-phase 1.5 kW Silicon Carbide based hardware prototype in grid-connected mode is developed to validate the performance of the proposed topologies. Experimental results show that the maximum reduction of 68.8% in ( $6f_{1}$ ) harmonic component in DC input current is achieved in active filter based Topology II without any significant detrimental effect on THD in AC line currents and inverter efficiency as compared to standard topology.