Deliang Wu

Prof. Deliang Wu

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DWDeliang Wu
Deliang Wu
HQHafsa Qamar
Hafsa Qamar
HQHaleema Qamar
Haleema Qamar
RARajapandian Ayyanar
Rajapandian Ayyanar
A bus-clamping space vector pulsewidth modulation (PWM) called 240°-clamped PWM (240CPWM) is analyzed for three-phase converters that have a cascaded connection of a dc-dc stage and a dc-ac stage. A direct application of the proposed concept is electric vehicle (EV) traction inverters that employ a dc-dc stage to interface a relatively low-voltage battery to a high-voltage motor. The 240CPWM method has the major advantages of clamping a phase to the positive or negative rail for 240° in a fundamental period, clamping of two phases simultaneously at any given instant, and use of only active states, completely eliminating the use of zero states. These characteristics lead to more than seven times reduction in switching losses of the inverter at unity power factor compared to CSVPWM, comparable or better total harmonic distortion (THD) performance, significant reduction in common-mode voltage and high efficiency. The THD of the line current is analyzed using the notion of stator flux ripple and compared with conventional and discontinuous PWM methods. The switching loss characteristics under different power factor conditions are discussed. Experimental results from a 10-kW hardware prototype are presented. The full load efficiency with the proposed 240CPWM for the dc-ac stage exceeds 99% even with Si insulated-gate bipolar transistors (IGBTs).

30 September 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
DWDeliang Wu
Deliang Wu
RARajapandian Ayyanar
Rajapandian Ayyanar
MSMadhura Sondharangalla
Madhura Sondharangalla
TMTobin Meyers
Tobin Meyers
An isolated active-clamped single-ended primary-inductor converter (SEPIC) power factor correction (PFC) converter based on SiC devices is presented. The impact of the resonant inductance on the switch voltage stress and range of zero-voltage switching is analyzed. Analytical expressions for the operating points of the switches over the line cycle are derived and used to evaluate the switching loss. Resonant inductance and snubber capacitance are chosen based on the analysis to reduce the switching loss without overstress of the switches. Lossless diode clamp circuits are designed for the output diode so that the peak voltage and extra losses due to device parasitics-induced oscillation are significantly reduced. The analysis is validated with a 2-kW single-phase PFC rectifier module with a peak efficiency of 96.56% at the 200-kHz switching frequency, total harmonic distortion (THD) < 2%, and power density of 58 W/in 3 .

23 May 2017 in BMC Bioinformatics
Verified
Journal Article
Open access
PDF file
ZWzhuo wang
zhuo wang
SJShuilin Jin
Shuilin Jin
GLGuiyou Liu
Guiyou Liu
XZXiurui Zhang
Xiurui Zhang
NWNan Wang
Nan Wang
YWYadong Wang
Yadong Wang
The development of single-cell RNA sequencing has enabled profound discoveries in biology, ranging from the dissection of the composition of complex tissues to the identification of novel cell types and dynamics in some specialized cellular environments. However, the large-scale generation of single-cell RNA-seq (scRNA-seq) data collected at multiple time points remains a challenge to effective measurement gene expression patterns in transcriptome analysis. We present an algorithm based on the Dynamic Time Warping score (DTWscore) combined with time-series data, that enables the detection of gene expression changes across scRNA-seq samples and recovery of potential cell types from complex mixtures of multiple cell types. The DTWscore successfully classify cells of different types with the most highly variable genes from time-series scRNA-seq data. The study was confined to methods that are implemented and available within the R framework. Sample datasets and R packages are available at https://github.com/xiaoxiaoxier/DTWscore .

20 July 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SWShuang Wang
Shuang Wang
ZLZhiwei Li
Zhiwei Li
DWDeliang Wu
Deliang Wu
JZJianfei Zhao
Jianfei Zhao
In surface-mounted permanent magnet synchronous motor (SPMSM) low-speed sensorless control, the high-frequency sinusoidal voltage injection method for rotor position estimation is affected by the low saturation salient rate of SPMSM and the system delay, resulting in estimation error. This article proposes a dual-demodulation method utilizing the high-frequency positive- and negative-sequence stator current of the motor. This method is based on the principle of maximizing the effect of the salient inductance component and minimizing the significant component of noise, which improves the utilization of the current containing angle information and increases the signal-to-noise ratio of the position angle error fed to the rotor position observer. The dc bias of the current caused by system delay is also eliminated so that the accuracy of position estimation is improved. The proposed method is verified by experiment, and the results show that the accuracy of the estimated rotor position and dynamic performance of the estimator is greatly improved compared to existing methods.

11 July 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SWShuang Wang
Shuang Wang
JLJunwei Li
Junwei Li
JZJianfei Zhao
Jianfei Zhao
DWDeliang Wu
Deliang Wu
Resolvers are commonly utilized as position sensors to gather angular data. The accuracy of resolver-to-digital conversion (RDC) may be hampered by response times and systematic errors in the demodulation and decoding of resolvers, though. A demodulation technique based on a multistage notch filter is proposed for the phase delay caused by employing a low-pass filter (LPF) in the signal demodulation process. This demodulation algorithm can enhance the decoding system’s response capacity while also removing the specified harmonics. An improved double second-order generalized integrator with frequency-locked loop (IDSOGI-FLL) is developed to extract the positive sequence components of the sine and cosine signals of the resolver in order to address the systematic faults present in the resolver. In comparison to traditional DSOGI-FLL, IDSOGI-FLL has the same amplitude and phase error suppression capabilities as DSOGI-FLL, but it makes up for the DC offset error suppression capability that is lacking in DSOGI-FLL. The effectiveness of the strategy is demonstrated by the experimental results.

27 October 2021 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
SWShuang Wang
Shuang Wang
YZYuanyuan Zhang
Yuanyuan Zhang
DWDeliang Wu
Deliang Wu
JZJianfei Zhao
Jianfei Zhao
YHYayuan Hu
Yayuan Hu
The model predictive current control (MPCC) technique has been an effective alternative for motor drive applications requiring fast dynamic response. However, the conventional MPCC suffers from high switching losses due to high switching frequency of the inverter. This study proposes a low average switching frequency MPCC method based on boundary‐constrained quadratically extrapolated current trajectory for a permanent magnet synchronous motor drive. First, a quadratic function‐based current prediction model is constructed to obtain the current trajectory in the long‐term future. Second, the boundary constraint is designed to obtain the prediction horizon which is changing in real‐time in order to ensure the validity of the predicted current trajectory. Finally, the cost function established according to the value of the prediction horizon is used to reduce the average switching frequency. In comparison with the conventional MPCC method, the proposed method can significantly reduce the switching frequency of the inverter. In the meantime, fast dynamic response and high steady‐state performance of the conventional MPCC method are preserved. Both simulation and experimental results of the proposed method and the conventional MPCC method are presented to verify the feasibility and advantages of the proposed method.