Felix Schwab

Felix Schwab

Auto-generated profile, based on publicly available information

Felix Schwab

Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Marchioninistr. 15, 81377 München, Germany

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2014 in Physica Medica
Verified
Journal Article
Closed access
FMFelix G. Meinel
Felix G. Meinel
FSFelix Schwab
Felix Schwab
AYAndre Yaroshenko
Andre Yaroshenko
AVAstrid Velroyen
Astrid Velroyen
MBMartin Bech
Martin Bech
KNKonstantin Nikolaou
Konstantin Nikolaou

1 September 2013 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Open access
FSF. Schwab
F. Schwab
SSS. Schleede
S. Schleede
DHD. Hahn
D. Hahn
MBM. Bech
M. Bech
JHJ. Herzen
J. Herzen
FMFelix G. Meinel
Felix G. Meinel
An experimental comparison of the contrast-to-noise ratio (CNR) between transmission and dark-field signals in grating-based X-ray imaging for ex-vivo murine lung tissue. Lungs from three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Background noise of transmission and dark-field signal was quantified by measuring the standard deviation in a region of interest (ROI) placed in a homogeneous area outside the specimen. Image contrast was quantified by measuring the signal range in rectangular ROIs placed in central and peripheral lung parenchyma. The relative contrast gain (RCG) of dark-field over transmission images was calculated as CNRDF / CNRT. In all images, there was a trend for contrast-to-noise ratios of dark-field images (CNRDF) to be higher than for transmission images (CNRT) for all ROIs (median 61 vs. 38, p=0.10), but the difference was statistically significant only for peripheral ROIs (61 vs. 32, p=0.03). Median RCG was >1 for all ROIs (1.84). RCG values were significantly smaller for central ROIs than for peripheral ROIs (1.34 vs. 2.43, p=0.03). The contrast-to-noise ratio of dark-field images compares more favorably to the contrast-to-noise ratio of transmission images for peripheral lung regions as compared to central regions. For any specific specimen, a calculation of the RCG allows comparing which X-ray modality (dark-field or transmission imaging) produces better contrast-to-noise characteristics in a well-defined ROI.

31 March 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
FSFelix Schwab
Felix Schwab
MIMichael Ingrisch
Michael Ingrisch
RMRoy Marcus
Roy Marcus
FBFabian Bamberg
Fabian Bamberg
KHKristof Hildebrandt
Kristof Hildebrandt
DTDaniel Theisen
Daniel Theisen

1 March 2013 in Investigative Radiology
Verified
Journal Article
Closed access
FSFelix Schwab
Felix Schwab
FSFlorian Schwarz
Florian Schwarz
ODOlaf Dietrich
Olaf Dietrich
TLTitus Lanz
Titus Lanz
FRFrank Resmer
Frank Resmer
DTDaniel Theisen
Daniel Theisen
Objectives The aim of this study was to evaluate free-breathing single-shot real-time cine imaging for functional cardiac imaging at 3 T with increased spatial resolution. Special emphasis of this study was placed on the influence of parallel imaging techniques. Materials and Methods Gradient echo phantom images were acquired with GRAPPA and modified SENSE reconstruction using both integrated and separate reference scans as well as TGRAPPA and TSENSE. In vivo measurements were performed for GRAPPA reconstruction with an integrated and a separate reference scan, as well as TGRAPPA using balanced steady-state free precession protocols. Three clinical protocols, rtLRInt (Tres = 51.3 milliseconds; voxel, 2.5 × 5.0 × 10 mm3), rtMRSep (Tres = 48.8 milliseconds; voxel, 1.9 × 3.1 × 10 mm3), and rtHRSep (Tres = 48.3 milliseconds; voxel, 1.6 × 2.6 × 10 mm3), were investigated on 20 volunteers using GRAPPA reconstruction with internal as well as separate reference scans. End-diastolic volume, end-systolic volume, ejection fraction, peak ejection rate, peak filling rate, and myocardial mass were evaluated for the left ventricle and compared with an electrocardiogram-triggered segmented readout cine protocol used as standard of reference. All studies were performed at 3 T. Results Phantom and in vivo data demonstrate that the combination of GRAPPA reconstruction with a separate reference scan provides an optimal compromise of image quality as well as spatial and temporal resolution. Functional values (P values) for the standard of reference, rtLRInt, rtMRSep, and rtHRSep end-diastolic volume were 141 ± 24 mL, 138 ± 21 mL, 138 ± 19 mL, and 128 ± 33 mL, respectively (P = 0.7, 0.7, 0.4); end-systolic volume, 55 ± 15 mL, 61 ± 14 mL, 58 ± 12 mL, and 55 ± 20 mL, respectively (P = 0.23, 0.43, 0.62); ejection fraction, 61% ± 5%, 57% ± 5%, 58% ± 4%, and 56% ± 8%, respectively (P = 0.01, 0.11, 0.06); peak ejection rate, 481 ± 73 mL/s, 425 ± 62 mL/s, 434 ± 67 mL/s, and 381 ± 86 mL/s, respectively (P = 0.03, 0.04, 0.01); peak filling rate, 555 ± 80 mL/s, 480 ± 70 mL/s, 500 ± 70 mL/s, and 438 ± 108 mL/s, respectively (P= 0.007, 0.05, 0.004); and myocardial mass, 137 ± 26 g, 141 ± 25 g, 141 ± 23 g, and 130 ± 31 g, respectively (P = 0.62, 0.54, 0.99). Conclusions Using a separate reference scan and high acceleration factors up to R = 6, single-shot real-time cardiac imaging offers adequate temporal and spatial resolution for accurate assessment of global left ventricular function in free breathing with short examination times.