Roger Shuttleworth

Roger Shuttleworth

Auto-generated profile, based on publicly available information

Roger Shuttleworth

Department of Electrical and Electronic Engineering, The University of Manchester, Manchester, U.K.

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Christos ZachariadesChristos Zachariades
Christos Zachariades
RSRoger Shuttleworth
Roger Shuttleworth
RGRiccardo Giussani
Riccardo Giussani
This paper reports on the development and testing of a novel barrier sensor for UHF Partial Discharge (PD) detection in gas-insulated equipment. The sensor features a unique dual-slot planar antenna backed by an air-filled cavity. The dual-slot arrangement allows different parts of the antenna to resonate at different frequency ranges in the UHF spectrum. As a result, the sensor exhibits broader bandwidth and higher sensitivity than other barrier sensors. Finite Element Analysis simulations have been used to optimize the sensor design. Furthermore, testing using a specially made PD test rig, GTEM cell testing and testing on a gas-insulated line section in the high voltage laboratory, have validated the simulation results and the capabilities of the sensor. The Dual-Slot Barrier (DSB) sensor exhibits a bandwidth of 0.3 -2.0 GHz with a mean effective height of 13 mm, and an effective height above 2 mm for 90% of the frequency range. The sensor can be used with both wideband instruments, such as oscilloscopes, and narrow band instruments such as frequency downconverters. Additionally, its optimized dimensions and unique replaceable sealing attachment ensure maximum compatibility for retrofitting on a wide range of equipment.

29 April 2016 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
QLQi Li
Qi Li
SRSimon M. Rowland
Simon M. Rowland
IDIain Dupere
Iain Dupere
RSRoger Shuttleworth
Roger Shuttleworth
Emerging technologies associated with conductors and transmission towers require a re-evaluation of models of audible noise generated by overhead line conductors. Measurements on which existing commercial models were developed were typically performed on a single, classical design of conductor around 50 years ago. Within this paper, an ac testing facility employing a semianechoic chamber and a novel measurement procedure are proposed to give accurate determination of acoustic emission from overhead line conductors. The reproducibility of these measurements is significantly above traditional testing methods, but is shown to be heavily dependent on the chosen wetting technique. It is found that to achieve an accurate result, background acoustic noise control is essential especially for lower frequencies of power frequency harmonics. A direct comparison is reported for conductor samples with various physical characteristics. The analysis of results gives power utilities valuable information for selecting quieter conductors for overhead lines. The magnitude of high-frequency audible noise generated above 1 kHz is shown to be closely related to corona discharge activity, while the acoustic emission below 1 kHz is determined by the size distribution of droplets.

17 March 2019 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Open access
DVDamian Sergio Vilchis-Rodriguez
Damian Sergio Vilchis-Rodriguez
RSRoger Shuttleworth
Roger Shuttleworth
ASAlexander C. Smith
Alexander C. Smith
MBMike Barnes
Mike Barnes
This paper details the design, construction, and test of a lightweight, low energy usage Thomson Coil actuator for the operation of a commercial medium-voltage vacuum switch. A novel latching design, directly linked to the actuator armature, helps to keep the actuator mass at minimum. Experimental results show that 125 J of electric energy is sufficient for operation of a commercial 27 kV vacuum interrupter in times suitable for medium-voltage dc protection applications. The use of high conductor density coils is shown to play a key role on the observed actuator performance. Finite element simulations are used to demonstrate that shorter operation times are feasible, without augmenting the consumed electrical energy, by further increasing coil conductor density.

1 January 2011
Verified
Conference Paper
Closed access
Thaiyal Naayagi RamasamyThaiyal Naayagi Ramasamy
Thaiyal Naayagi Ramasamy
AFAndrew Forsyth
Andrew Forsyth
RSR. Shuttleworth
R. Shuttleworth
This paper investigates the effect of snubber capacitor on the zero voltage switching (ZVS) boundary of the dual active bridge (DAB) DC-DC converter. The analysis is performed to determine the minimum current required during transistor turn-off to achieve successful ZVS and the ZVS boundary operating conditions of the converter are obtained. The operation of the converter during transistor turn-off with snubber capacitor is explained. SABER simulations verify the operation of the converter under ZVS thereby confirming the accuracy of the analysis. Experimental results corresponding to the ZVS boundary of the converter prototype for 6.4kW, 390V/175V, 20 kHz operation are included to support the analysis.

11 March 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MZMin Zhang
Min Zhang
ABAlexey Bodrov
Alexey Bodrov
RSRoger Shuttleworth
Roger Shuttleworth
MIMatteo Felice Iacchetti
Matteo Felice Iacchetti
Linear Generators (LGs) are frequently used for energy harvesting with free-piston Stirling engines, thermoacoustic engines and wave energy converters. This paper presents a control strategy to track and maintain LG resonance conditions in real time. The algorithm is based on the LG response to a low-frequency amplitude modulation of the current component in phase with the instantaneous position (d-axis). The averaged product of modulated airgap power and modulation signal is fed into a controller to adjust the d-axis current and restore resonance. The use of airgap power instead of dc power improves resonance tracking accuracy and eliminates steady-state low-frequency stroke oscillations. The paper presents a full theoretical analysis providing accurate steady-state and small-signal models for control synthesis. The broad experimental validation included in the paper proves that the control is able to restore resonance even when the force-source introduces significant additional mechanical impedance.

1 March 1995 in IEE Proceedings - Electric Power Applications
Verified
Journal Article
Closed access
DAD.W. Auckland
D.W. Auckland
RSR. Shuttleworth
R. Shuttleworth
ALA.C. Luff
A.C. Luff
BAB.P. Axcell
B.P. Axcell
ARAbdul Rashid Abdul Rahman
Abdul Rashid Abdul Rahman