To investigate the effect of training on scanning accuracy of complete arch scans (CAS) performed by first-time users, with a distinction made between specific training (repeated performance of CAS) and nonspecific training (simple use of an intraoral optical scanner for a sextant scan in the context of a CAD/CAM teaching module). A total of 36 students with no experience in intraoral scanning were randomized into three groups (n = 12 per group) according to the number of CAS sessions: three sessions (3S), two sessions (2S), and one session (1S). Each student had to perform 10 CAS per scanning session. Sessions were scheduled at T0, T1, and T2 for group 3S; at T0 and T2 for group 2S; and at T2 for group 1S. Before the final scanning session in each group (ie, the first scanning session in group 1S), the students completed a CAD/CAM teaching module, which included fabrication of a monolithic crown in a fully digital chairside workflow. In all groups, repeated CAS resulted in improved scanning accuracy. Participation in the CAD/CAM module had a positive effect on initial accuracy for CAS. Mean absolute deviations in cross-arch distance were 84 μm (T0), 68 μm (T1), and 63 μm (T2) for group 3S; 79 μm (T0) and 61 μm (T2) for group 2S; and 67 μm (T2) for group 1S. To perform CAS with the best possible accuracy, specific training is highly recommended. In addition, nonspecific training leads to an improvement in initial scanning accuracy.
Objectives Evaluating structural changes in oral epithelium can assist with the diagnosis of cancerous lesions. Two-dimensional (2D) non-invasive optical coherence tomography (OCT) is an established technique for this purpose. The objective of this study was to develop and test the diagnostic accuracy of a three-dimensional (3D) evaluation method. Methods The oral lip mucosa of 10 healthy volunteers was scanned using an 870-nm spectral-domain OCT device (SD-OCT) with enhanced depth imaging (EDI). Four raters semi-automatically segmented the epithelial layer twice. Thus, eighty 3D datasets were created and analyzed for epithelial thickness. To provide a reference standard for comparison, the raters took cross-sectional 2D measurements at representative sites. The correlation between the 2D and 3D measurements, as well as intra- and inter-rater reliability, were analyzed using intraclass correlation coefficients (ICC). Results Mean epithelial thickness was 280 ± 64μm (range 178–500 μm) and 268 ± 49μm (range 163–425 μm) for the 2D and 3D analysis, respectively. The inter-modality correlation of the thickness values was good (ICC: 0.76 [0.626–0.846]), indicating that 3D analysis of epithelial thickness provides valid results. Intra-rater and inter-rater reliability were good (3D analysis) and excellent (2D analysis), suggesting high reproducibility. Conclusions Diagnostic accuracy was high for the developed 3D analysis of oral epithelia using non-invasive, radiation-free OCT imaging. Clinical significance This new 3D technique could potentially be used to improve time-efficiency and quality in the diagnosis of epithelial lesions compared with the 2D reference standard.