Ross Aaron Petrella

Ross Aaron Petrella

Auto-generated profile, based on publicly available information

Ross Aaron Petrella

UNCNCSU Joint Department of Biomedical Engineering, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2016 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
RPRoss A. Petrella
Ross A. Petrella
KSKarl H. Schoenbach
Karl H. Schoenbach
SXShu Xiao
Shu Xiao
A dielectrically loaded wideband rod antenna has been studied as a pulse delivery system to subcutaneous tissues. Simulation results applying 100-ps electrical pulse show that it allows us to generate a critical electric field for biological effects, such as brain stimulation, in the range of several centimeters. In order to reach the critical electric field for biological effects, which is ~20 kV/cm, at a depth of 2 cm, the input voltage needs to be 175 kV. The electric field spot size in the brain at this position is ~1 cm 2 . Experimental studies in free space with a conical antenna (part of the antenna system) with aluminum nitride as the dielectric have confirmed the accuracy of the simulation. These results set the foundation for high-voltage in situ experiments on the complete antenna system and the delivery of pulses to a biological tissue.

13 May 2016 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
SXShu Xiao
Shu Xiao
ISIurii Semenov
Iurii Semenov
RPRoss Petrella
Ross Petrella
Andrei PakhomovAndrei Pakhomov
Andrei Pakhomov
KSKarl H. Schoenbach
Karl H. Schoenbach

13 August 2018 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
RPRoss A Petrella
Ross A Petrella
PMPeter Mollica
Peter Mollica
MZMartina Zamponi
Martina Zamponi
JRJohn A Reid
John A Reid
SXShu Xiao
Shu Xiao
PSPatrick Sachs
Patrick Sachs
Objective . Picosecond pulse electric fields (psPEF) have the potential to elicit functional changes in mammalian cells in a non-contact manner. Such electro-manipulation of pluripotent and multipotent cells could be a tool in both neural interface and tissue engineering. Here, we describe the potential of psPEF in directing neural stem cells (NSCs) gene expression, metabolism, and proliferation. As a comparison mesenchymal stem cells (MSCs) were also tested. Approach . A psPEF electrode was anchored on a customized commercially available 3D printer, which allowed us to deliver pulses with high spatial precision and systematically control the electrode position in three-axes. When the electrodes are continuously energized and their position is shifted by the 3D printer, large numbers of cells on a surface can be exposed to a uniform psPEF. With two electric field strengths (20 and 40 kV cm −1 ), cell responses, including cell viability, proliferation, and gene expression assays, were quantified and analyzed. Main results . Analysis revealed both NSCs and MSCs showed no significant cell death after treatments. Both cell types exhibited an increased metabolic reduction; however, the response rate for MSCs was sensitive to the change of electric field strength, but for NSCs, it appeared independent of electric field strength. The change in proliferation rate was cell-type specific. MSCs underwent no significant change in proliferation whereas NSCs exhibited an electric field dependent response with the higher electric field producing less proliferation. Further, NSCs showed an upregulation of glial fibrillary acidic protein (GFAP) after 24 h to 40 kV cm −1 , which is characteristic of astrocyte specific differentiation. Significance . Changes in cell metabolism, proliferation, and gene expression after picosecond pulsed electric field exposure are cell type specific.

15 May 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RPRoss Aaron Petrella
Ross Aaron Petrella
CFChristopher C. Fesmire
Christopher C. Fesmire
JKJacob D. Kaufman
Jacob D. Kaufman
NTNomi Topasna
Nomi Topasna
MSMichael B. Sano
Michael B. Sano
Objective: To evaluate the effect of a closed-loop temperature based feedback algorithm on ablative outcomes for pulsed electric field treatments. Methods: A 3D tumor model of glioblastoma was used to assess the impact of 2 μs duration bipolar waveforms on viability following exposure to open and closed-loop protocols. Closed-loop treatments evaluated transient temperature increases of 5, 10, 15, or 22°C above baseline. Results: The temperature controlled ablation diameters were conditionally different than the open-loop treatments and closed-loop treatments generally produced smaller ablations. Closed-loop control enabled the investigation of treatments with steady state 42°C hyperthermic conditions which were not feasible without active feedback. Baseline closed-loop treatments at 20°C resulted in ablations measuring 9.9±0.3 mm in diameter while 37°C treatments were 20% larger (p < 0.0001) measuring 11.8±0.3 mm indicating that this protocol induces a thermally mediated biological response. Conclusion: A closed-loop control algorithm which modulated the delay between successive pulse waveforms to achieve stable target temperatures was demonstrated. Algorithmic control enabled the evaluation of specific treatment parameters at physiological temperatures not possible with open-loop systems due to excessive Joule heating. Significance: Irreversible electroporation is generally considered to be a non-thermal ablation modality and temperature monitoring is not part of the standard clinical practice. The results of this study indicate ablative outcomes due to exposure to pulses on the order of one microsecond may be thermally mediated and dependent on local tissue temperatures. The results of this study set the foundation for experiments in vivo utilizing temperature control algorithms.

8 September 2016 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
RPRoss A. Petrella
Ross A. Petrella
SXShu Xiao
Shu Xiao
SKSunao Katsuki
Sunao Katsuki
An air core transformer that linearly integrates a capacitor bank as well as a selfclosing switch into the primary winding (LIP) was designed to achieve ultrafast charging. Limiting stray inductance and maximizing the uncoupled dual resonance of the primary and secondary windings were the primary design criteria. To show this concept, two transformers with an uncoupled resonant frequency of approximately 8 MHz were designed for a low voltage output (several kV) and a high voltage output (>100 kV). The design was simulated in a Multisim discrete circuit model and a CST hybrid model which includes the transformer's 3-D structure as well as discrete circuit components. The discrete output (voltage and current) as well as the distributed parameters (electric field distribution and surface current density distribution) for the transformer were obtained. These designs were validated by experimental results. We show that their respective resonance characteristic and voltage gain are accurately predicted by the simulated values, demonstrating the design procedure is valid for both low voltage and high voltage applications. For the high voltage transformer, it has a voltage gain of 3-4. The maximum output voltage was tested up to 120 kV. A charging pulse with a rise time of less than 100 ns was obtained.

25 December 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CFChristopher C. Fesmire
Christopher C. Fesmire
RWRobert Williamson
Robert Williamson
RPRoss A. Petrella
Ross A. Petrella
JKJacob D. Kaufman
Jacob D. Kaufman
NTNomi Topasna
Nomi Topasna
MSMichael B. Sano
Michael B. Sano
Objective: This study sought to investigate a novel strategy using temperature-controlled delivery of nanosecond pulsed electric fields as an alternative to the 50-100 microsecond pulses used for irreversible electroporation. Methods: INSPIRE treatments were carried out at two temperatures in 3D tumor models using doses between 0.001 s and 0.1 s. The resulting treatment zones were quantified using viability staining and lethal electric field intensities were determined numerically. Computational modeling was then used to determine parameters necessary for INSPIRE treatments to achieve equivalent treatment zones to clinical electroporation treatments and evaluate the potential for these treatments to induce deleterious thermal damage. Results: Lethal thresholds between 1109 and 709 V/cm were found for nominal 0.01 s treatments with pulses between 350 ns and 2000 ns at physiological temperatures. Further increases in dose resulted in significant decreases in lethal thresholds. Given these experimental results, treatment zones comparable to clinical electroporation are possible by increasing the dose and voltage used with nanosecond duration pulses. Temperature-controlled simulations indicate minimal thermal cell death while achieving equivalent treatment volumes to clinical electroporation. Conclusion: Nanosecond electrical pulses can achieve comparable outcomes to traditional electroporation provided sufficient electrical doses or voltages are applied. The use of temperature-controlled delivery may minimize thermal damage during treatment. Significance: Intense muscle stimulation and the need for cardiac gating have limited irreversible electroporation. Nanosecond pulses can alleviate these challenges, but traditionally have produced significantly smaller treatment zones. This study suggests that larger ablation volumes may be possible with the INSPIRE approach and that future in vivo studies are warranted.