Saba Adabi

Saba Adabi

Auto-generated profile, based on publicly available information

Saba Adabi

Roma Tre Univ. (Italy)

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
AMAli Mahloojifar
Ali Mahloojifar
MOMahdi Orooji
Mahdi Orooji
SASaba Adabi
Saba Adabi
MNMohammadreza Nasiriavanaki
Mohammadreza Nasiriavanaki
Photoacoustic imaging (PAI) is an emerging medical imaging modality capable of providing high spatial resolution of Ultrasound (US) imaging and high contrast of optical imaging. Delay-and-Sum (DAS) is the most common beamforming algorithm in PAI. However, using DAS beamformer leads to low resolution images and considerable contribution of offaxis signals. A new paradigm namely Delay-Multiply-and-Sum (DMAS), which was originally used as a reconstruction algorithm in confocal microwave imaging, was introduced to overcome the challenges in DAS. DMAS was used in PAI systems and it was shown that this algorithm results in resolution improvement and sidelobe degrading. However, DMAS is still sensitive to high levels of noise, and resolution improvement is not satisfying. Here, we propose a novel algorithm based on DAS algebra inside DMAS formula expansion, Double Stage DMAS (DSDMAS), which improves the image resolution and levels of sidelobe, and is much less sensitive to high level of noise compared to DMAS. The performance of DS-DMAS algorithm is evaluated numerically and experimentally. The resulted images are evaluated qualitatively and quantitatively using established quality metrics including signal-to-noise ratio (SNR), full-widthhalf- maximum (FWHM) and contrast ratio (CR). It is shown that DS-DMAS outperforms DAS and DMAS at the expense of higher computational load. DS-DMAS reduces the lateral valley for about 15 dB and improves the SNR and FWHM better than 13% and 30%, respectively. Moreover, the levels of sidelobe are reduced for about 10 dB in comparison with those in DMAS.

6 February 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
AMAli Mahloojifar
Ali Mahloojifar
MOMahdi Orooji
Mahdi Orooji
KKKarl Kratkiewicz
Karl Kratkiewicz
SASaba Adabi
Saba Adabi
MNMohammadreza Nasiriavanaki
Mohammadreza Nasiriavanaki
The Journal of Biomedical Optics (JBO) publishes peer-reviewed papers on the use of novel optical systems and techniques for improved health care and biomedical research.

20 December 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SASaba Adabi
Saba Adabi
MHMatin Hosseinzadeh
Matin Hosseinzadeh
SNShahryar Noei
Shahryar Noei
SCSilvia Conforto
Silvia Conforto
SDSteven Daveluy
Steven Daveluy
KAKamran Avanaki
Kamran Avanaki
Currently, diagnosis of skin diseases is based primarily on the visual pattern recognition skills and expertise of the physician observing the lesion. Even though dermatologists are trained to recognize patterns of morphology, it is still a subjective visual assessment. Tools for automated pattern recognition can provide objective information to support clinical decision-making. Noninvasive skin imaging techniques provide complementary information to the clinician. In recent years, optical coherence tomography (OCT) has become a powerful skin imaging technique. According to specific functional needs, skin architecture varies across different parts of the body, as do the textural characteristics in OCT images. There is, therefore, a critical need to systematically analyze OCT images from different body sites, to identify their significant qualitative and quantitative differences. Sixty-three optical and textural features extracted from OCT images of healthy and diseased skin are analyzed and, in conjunction with decision-theoretic approaches, used to create computational models of the diseases. We demonstrate that these models provide objective information to the clinician to assist in the diagnosis of abnormalities of cutaneous microstructure, and hence, aid in the determination of treatment. Specifically, we demonstrate the performance of this methodology on differentiating basal cell carcinoma (BCC) and squamous cell carcinoma (SCC) from healthy tissue.

7 April 2017 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ATAdeleh Taghavikhalilbad
Adeleh Taghavikhalilbad
SASaba Adabi
Saba Adabi
ACAnne Clayton
Anne Clayton
HSHadi Soltanizadeh
Hadi Soltanizadeh
DMDarius Mehregan
Darius Mehregan
KAKamran Avanaki
Kamran Avanaki
Identifying the location of the dermal epidermal junction (DEJ) in skin images is essential in several clinical applications of dermatology such as epidermal thickness determination in healthy versus unhealthy skins, such as basal cell carcinoma. Optical coherence tomography (OCT) facilitates the visual detection of DEJ in vivo. However, due to the granular texture of speckle and a low contrast between dermis and epidermis, a skin border detection method is required for DEJ localization. Current DEJ algorithms work well for skins with a visible differentiable epidermal layer but not for the skins of different body sites. In this paper, we present a semi-automated DEJ localization algorithm based on graph theory for OCT images of skin. The proposed algorithm is performed in an interactive framework by a graphical representation of an attenuation coefficient map through a uniform-cost search method. For border thinning, a fuzzy-based nonlinear smoothing technique is used. For evaluation, the DEJ detection method is used by several experts, and the results are compared with manual segmentation. The mean thickness error between the proposed algorithm and the experts’ opinion in the Bland–Altman plot is computed as 14 μm; this is comparable to the resolution of the OCT. The results suggest that the proposed image processing method successfully detects DEJ.

24 January 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
SASaba Adabi
Saba Adabi
ERElaheh Rashedi
Elaheh Rashedi
ACAnne Clayton
Anne Clayton
Hamed Mohebbi-KalkhoranHamed Mohebbi-Kalkhoran
Hamed Mohebbi-Kalkhoran
XCXue-Wen Chen
Xue-Wen Chen
MNMohammadreza Nasiriavanaki
Mohammadreza Nasiriavanaki
Optical coherence tomography (OCT) is a prevalent, interferometric, high-resolution imaging method with broad biomedical applications. Nonetheless, OCT images suffer from an artifact called speckle, which degrades the image quality. Digital filters offer an opportunity for image improvement in clinical OCT devices, where hardware modification to enhance images is expensive. To reduce speckle, a wide variety of digital filters have been proposed; selecting the most appropriate filter for an OCT image/image set is a challenging decision, especially in dermatology applications of OCT where a different variety of tissues are imaged. To tackle this challenge, we propose an expandable learnable despeckling framework, we call LDF. LDF decides which speckle reduction algorithm is most effective on a given image by learning a figure of merit (FOM) as a single quantitative image assessment measure. LDF is learnable, which means when implemented on an OCT machine, each given image/image set is retrained and its performance is improved. Also, LDF is expandable, meaning that any despeckling algorithm can easily be added to it. The architecture of LDF includes two main parts: (i) an autoencoder neural network and (ii) filter classifier. The autoencoder learns the FOM based on several quality assessment measures obtained from the OCT image including signal-to-noise ratio, contrast-to-noise ratio, equivalent number of looks, edge preservation index, and mean structural similarity index. Subsequently, the filter classifier identifies the most efficient filter from the following categories: (a) sliding window filters including median, mean, and symmetric nearest neighborhood, (b) adaptive statistical-based filters including Wiener, homomorphic Lee, and Kuwahara, and (c) edge preserved patch or pixel correlation-based filters including nonlocal mean, total variation, and block matching three-dimensional filtering.

16 November 2017 in Skin Research and Technology
Verified
Journal Article
Closed access
PDF file
SASaba Adabi
Saba Adabi
AFAudrey Fotouhi
Audrey Fotouhi
QXQiuyun Xu
Qiuyun Xu
SDSteve Daveluy
Steve Daveluy
DMDarius Mehregan
Darius Mehregan
KAKamran Avanaki
Kamran Avanaki