4 September 2024 in Physica Scripta
The fast circuit breaker can achieve the rapid removal of short-circuit faults, which is of paramount significance for ensuring the safe and stable operation of the power system. This paper proposes a design scheme for the arc extinguishing chamber of the 550 kV fast circuit breaker, establishes a mathematical model of magneto-hydro-dynamics (MHD) arc, and calculates the trends of gas pressure, arc temperature, and nozzle airflow velocity inside the fast interruption arc extinguishing chamber under different arcing times. It compares and analyzes key interruption parameters such as airflow field characteristics, arc conductance, and post-arc current, researches the interruption performance of fast circuit breakers under different arcing times, and determines the prototype design scheme. It is found that the design scheme of the arc extinguishing chamber with the opening speed of 13.5 m s−1, inflation pressure of 0.6 MPa, overtravel of 33 mm, cylinder radius of 80 mm, and nozzle throat length of 27 mm can compress the short arcing time to 6 ms, while maintaining good interruption performance for medium and long arcing, meeting the requirements of fast interruption. The prototype successfully passed the T100(s) interruption test, achieving a short arcing time of 6.2 ms, as well as corresponding medium and long arcing interruptions, verifying the effectiveness of the simulation calculations. The 550 kV fast circuit breaker successfully reduced the total interruption time to within 25 ms, and the research results successfully guided the development of the fast circuit breaker prototype.
26 September 2025 in IEEE Transactions on Power Delivery
Conventional operating mechanisms suffer from inherent limitations including prolonged response time and inadequate driving speed, which fail to satisfy the stringent opening time requirements of 550 kV fast circuit breakers. To address this, we propose a novel operating mechanism with fast response and high-speed motion, establishing a coupling relationship between the repulsion mechanism and the hydraulic mechanism. A simulation model of the dynamic characteristics of the novel operating mechanism was constructed, and a multi-objective optimization algorithm was used to refine the repulsion mechanism’s design. The fast response characteristics, high-speed drive characteristics, and cushioning characteristics of the operating mechanism are analyzed. The research shows that with a repulsion mechanism design featuring an energy storage capacitor capacity of 7787 μF, a charging voltage of 1033 V, 45 coil turns, a coil thickness of 9 mm, a coil width of 2 mm, a repulsion plate thickness of 8 mm, and a repulsion plate radius of 103 mm, fast response is achieved in coordination with the hydraulic valve, reducing start-up time to 2.35 ms. With a hydraulic mechanism piston rod action area of 3160 mm2, the opening speed increases to 13.63 m/s, and the mechanical separation time of the contacts is reduced to 4.45 ms. An ideal cushioning structure was proposed. The research results successfully guided the development of a prototype fast operating mechanism.
22 July 2022 in IET Conference Proceedings
The mechanical properties of the transmission system have a great influence on the operation stability of high-speed breaking circuit breakers. This paper designs a 550kV high-speed breaking circuit breaker drive system, establishes a transient dynamics simulation model of the drive system, and compares and analyzes the contact movement characteristics and the force of each component during normal and high-speed opening processes. The research results show that the moving contact displacement and speed simulation results are highly consistent with the experimental test data, and the maximum error does not exceed 5%; the peak stress of each component of the high-speed circuit breaker transmission mechanism is far greater than that of the normal-speed circuit breaker, and the maximum load occurs in the substation The starting time of the brake; the stress peaks of the components of the transmission mechanism of the constant-speed circuit breaker are within the safety margin, and the maximum stress values of the guide rod joint and the crank arm in the transmission mechanism of the highspeed circuit breaker during the entire opening process are respectively 1003.6MPa and 717.44MPa, exceeding the yield strength of the material itself, there is a risk of damage.