23 August 2014 in Graefe's Archive for Clinical and Experimental Ophthalmology
Purpose To compare functional outcomes of Wavelight Allegretto Eye-Q 400Hz and Schwind Amaris 750S excimer laser for astigmatism between 2 and 7 diopters(D). Methods Prospective comparative non-randomized case series of 480 eyes assigned in two laser groups and further divided into myopic and mixed astigmatism subgroups. All treatments were centered on corneal vertex. One-year results were compared between the groups. Statistical analysis was performed using z-test. Results Both Allegretto and Amaris postoperative uncorrected distance visual acuity (UDVA) improved in comparison to preoperative corrected distance visual acuity (CDVA). The difference was significant in the Allegretto group for myopic astigmatism (p = 0.017). There was no difference in postoperative UDVA between lasers. Average sphere decreased in all groups for both lasers (p < 0.001) without difference in effectiveness of spherical correction between lasers for both groups. In Allegretto, average cylinder decreased from −3.30D to −0.55D in myopic astigmatism (p < 0.001) and from −3.84D to −0.85D in mixed astigmatism (p < 0.001). In Amaris average cylinder decreased from −3.21D to −0.43D in myopic astigmatism (p < 0.001) and from −3.66D to −0.58D in mixed astigmatism (p < 0.001). Amaris group had less residual astigmatism (myopic astigmatism p = 0.023, mixed astigmatism p < 0.001). Mean spherical aberration shifted from positive to negative in mixed astigmatism for both lasers. Conclusion Both lasers are effective in terms of UDVA, CDVA, spherical correction, and preservation of high-order aberrations. However, Amaris was more effective in cylinder correction.
24 September 2015 in Graefe's Archive for Clinical and Experimental Ophthalmology
1 February 2017 in Journal of Refractive Surgery
The predicted SIA power was up to 12% less than expected in cases of -6.00 diopters cylinder treated for myopic astigmatism using the Allegretto platform. The mean predicted angle of error (the angle between the SIA and TIA axes) was less than 4°, increasing to 12° for against-the-rule astigmatism. The Allegretto platform tended toward a clockwise axis rotational error, whereas the Amaris platform tended toward the opposite. [J Refract Surg. 2017;33(2):104-109.].
1 November 2016 in Cornea
To report a case of apparent corneal ectasia after intrastromal femtosecond laser treatment for presbyopia (INTRACOR). A healthy 56-year-old male with low hyperopia underwent an unremarkable bilateral INTRACOR procedure in March/April 2011. The patient was discharged after follow-up and returned 5 years later. Before discharge, the monocular logarithm of the minimal angle of resolution uncorrected distance visual acuity (UDVA) values were R, 0.0 and L, 0.10. In both eyes near (UNVA) visual acuities were 0.0. There were signs of slight posterior central corneal steepening without loss of corneal stability. Five years postop, monocular UDVA and UNVA values were 0.4 and 0.0, respectively. Ectasia was observed in both eyes, and the centrally placed 5 concentric rings after the INTRACOR procedure were visible under slit-lamp biomicroscopy. There is no clear reason to explain why the patient developed bilateral corneal steepening. It could be that the patient's corneal stromal fibers gradually weakened over this 5-year period.