Alma Biscevic

Dr. Alma Biscevic


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2018 in Seminars in Ophthalmology
Verified
Journal Article
Closed access
MBMaja Bohač
Maja Bohač
MKMateja Koncarevic
Mateja Koncarevic
APAdi Pasalic
Adi Pasalic
ABAlma Biscevic
Alma Biscevic
MMMaja Merlak
Maja Merlak
SPSudi Patel
Sudi Patel
Purpose: To report the incidence of postoperative ectasia after laser in situ keratomileusis (LASIK). Methods: A retrospective case review of 30,167 eyes (16,732 patients) was conducted following LASIK between August 2007 and August 2015. The follow-up was between 2 and 8 years. Tomography was performed after 2 years postop. After identifying cases of ectasia, the charts of these patients were examined to identify any common factors that may have predisposed them to develop ectasia. Results: Ten eyes of seven patients developed post-LASIK ectasia. Eight eyes had been treated for myopia and myopic astigmatism, two eyes for mixed astigmatism. There were no cases of ectasia after LASIK for hyperopia. All 10 cases of ectasia had a flap that was created using the Moria M2 mechanical microkeratome (average flap thickness 118.15 ± 12.88 µm) and refractive error corrected using the Wavelight Allegretto excimer laser. Retrospectively, most prevalent risk factors were thin cornea (≤ 500 µm, 50% of cases), anterior topographic map irregularities (e.g., asymmetric bow tie, 40% of cases), Ectasia Risk Score > 3 (40% of cases), percent tissue thickness alteration ≥ 40% (20% of cases) and low residual stromal bed (≤ 300 µm, 30% of cases). One eye had no identifiable risk factors. In the retrospective chart review 14.97% (4,506) of all the eyes had similar risk factors to the cases that went on to develop ectasia. Conclusion: The incidence of ectasia was 0.033% over 8 years. The incidence could be higher as some cases may destabilize beyond this period and some patients were lost to follow-up asymptomatic of any clinical signs. Other intrinsic factors may trigger the development of post LASIK ectasia. The current widely accepted risk factors are not sufficiently rigorous for screening out potential ectasia from developing after LASIK. There is a need to augment accuracy with higher sensitivity and specificity.

1 January 2019 in Acta Informatica Medica
Verified
Journal Article
Open access
APAjla Pidro
Ajla Pidro
ABAlma Biscevic
Alma Biscevic
MPMelisa Pjano
Melisa Pjano
IMIvana Mravicic
Ivana Mravicic
NBNita Bejdic
Nita Bejdic
MBMaja Bohac
Maja Bohac
In the field of ophthalmology, laser technology is used in many basic and clinical disciplines and specialities. It has played an important role in promoting the development of ophthalmology. This article is designed to review the evolution of laser technology in refractive surgeries in ophthalmology, mainly focusing on the characteristics of the excimer laser applied in corneal refractive surgery. This article was performed based on a literature review and Internet search through scientific databases such as PubMed, Scopus, Web of Science and Google Scholar. The literature on excimer laser technology addresses the technical and physical aspects of excimer lasers including types, characteristics and commercially available lasers on the market. The conclusion on this forum aims to help understand the benefits of excimer laser use in ophthalmology, with focus on correction of refractive errors.

23 August 2014 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Open access
PDF file
MBMaja Bohač
Maja Bohač
ABAlma Biscevic
Alma Biscevic
MKMateja Koncarevic
Mateja Koncarevic
MAMarija Anticic
Marija Anticic
NGNikica Gabric
Nikica Gabric
SPSudi Patel
Sudi Patel
Purpose To compare functional outcomes of Wavelight Allegretto Eye-Q 400Hz and Schwind Amaris 750S excimer laser for astigmatism between 2 and 7 diopters(D). Methods Prospective comparative non-randomized case series of 480 eyes assigned in two laser groups and further divided into myopic and mixed astigmatism subgroups. All treatments were centered on corneal vertex. One-year results were compared between the groups. Statistical analysis was performed using z-test. Results Both Allegretto and Amaris postoperative uncorrected distance visual acuity (UDVA) improved in comparison to preoperative corrected distance visual acuity (CDVA). The difference was significant in the Allegretto group for myopic astigmatism (p = 0.017). There was no difference in postoperative UDVA between lasers. Average sphere decreased in all groups for both lasers (p < 0.001) without difference in effectiveness of spherical correction between lasers for both groups. In Allegretto, average cylinder decreased from −3.30D to −0.55D in myopic astigmatism (p < 0.001) and from −3.84D to −0.85D in mixed astigmatism (p < 0.001). In Amaris average cylinder decreased from −3.21D to −0.43D in myopic astigmatism (p < 0.001) and from −3.66D to −0.58D in mixed astigmatism (p < 0.001). Amaris group had less residual astigmatism (myopic astigmatism p = 0.023, mixed astigmatism p < 0.001). Mean spherical aberration shifted from positive to negative in mixed astigmatism for both lasers. Conclusion Both lasers are effective in terms of UDVA, CDVA, spherical correction, and preservation of high-order aberrations. However, Amaris was more effective in cylinder correction.

1 January 2020 in Acta Informatica Medica
Verified
Journal Article
Open access
SGSenad Grisevic
Senad Grisevic
FGFanka Gilevska
Fanka Gilevska
ABAlma Biscevic
Alma Biscevic
MPMelisa Pjano
Melisa Pjano
MBMaja Bohac
Maja Bohac
APAjla Pidro
Ajla Pidro
Keratoconus is described as a degenerative bilateral, progressive, noninflammatory corneal disorder characterized by ectasia, thinning, and increased curvature. Keratoconus progression classification 1 year after performed crosslinking method in this study is based on the ABCD keratoconus grading system. To evaluate the possible keratoconus progression one year after performed a crosslinking (CXL) method based on the ABCD keratoconus grading system. Methods: Seventeen keratoconus patients (22 eyes) were included in this prospective study. CXL procedure was performed using the standard Dresden protocol at Eye Clinic Svjetlost Sarajevo with the inclusion period from January 2017 to January 2018. Twelve patients had monocular, and 5 patients had binocular treatments with follow up of 12 months. Preoperative and postoperative stages were compared using the ABCD keratoconus grading system measured on rotating Scheimpflug corneal tomography-based machine - Pentacam (Pentacam HR, Oculus Optikgeräte GmbH, Wetzlar, Germany). Out of 22 eyes, one eye had keratoconus stage I-II, 6 eyes had stage II, 4 eyes had stage III, and 9 eyes had stage III-IV. There was no statistically significant gradient change of keratoconus in comparison to one month after the surgery, p>0.05. There was no progression of the gradient when comparing to the preoperative stage. Corneal cross-linking could effectively stabilize the progression of keratoconus, as assessed by key corneal topographic parameters. Analyzing the trend of stage change in 12 months follow up after the crosslinking procedure of keratoconus patients there was no progression of a gradient in comparison to the preoperative stage. According to our results, we can conclude that CXL is a safe and effective procedure in treating keratoconus.

1 January 2017 in Medical Archives
Verified
Journal Article
Open access
MPMelisa Pjano
Melisa Pjano
APAjla Pidro
Ajla Pidro
ABAlma Biscevic
Alma Biscevic
SGSenad Grisevi
Senad Grisevi
BPBojana Pandzi
Bojana Pandzi
VCVesna Cerovic
Vesna Cerovic
The aim was to examine efficacy and safety after Implantable Collamer Lens (ICL) implantation for correction of myopia et myopic astigmatism. This prospective clinical study included 28 eyes of 16 patients which underwent implantation of ICL for correction of myopia up to -18,00 diopters (D) and myopic astigmatism up to -6,00 D in the Eye Clinic Svjetlost Sarajevo, from January 2013 to January 2016. Uncorrected distance visual acuity (UDVA), spherical equivalent (SE), corrected distance visual acuity (CDVA), intraocular pressure (IOP), endothelial cell (EC) density were evaluated at one, six and twelve months. For statistical analysis SPSS for Windows and Microsoft Excel were used. Out of 16 patients, with mean age of 28,21 ± 4,06 years, 12 of them had binocular and 4 of them had monocular procedure. After 12 months mean UDVA was 0,76 ± 0,16 compared to UDVA 0,04 ± 0,03 preoperatively. Mean SE preoperatively was -0,21 ± 0,27 D compared to -9,52 ± 3,69 D preoperatively. At 12 months one eye (3,57%) lost 2 Snellen lines. In this study 8 eyes (28,57%) gained 1 line, 5 eyes gained (17,56%) 2 lines, and 3 eyes (10,72%) gained 3 lines. EC loss was 5,50±4.71% after 12 months. There was no significant change of IOP by the end of 12 months follow up period. One haptic crack was reported as the only intraoperative complication. Three postoperative complications were: two lens rotations and one retinal detachment. Implantation of ICL is an effective and safe method for reducing or correcting myopia and myopic astigmatism.

1 January 2019 in Medical Archives
Verified
Journal Article
Open access
ABAlma Biscevic
Alma Biscevic
APAjla Pidro
Ajla Pidro
MPMelisa Pjano
Melisa Pjano
SGSenad Grisevic
Senad Grisevic
NZNina Ziga
Nina Ziga
MBMaja Bohac
Maja Bohac
To evaluate safety and efficacy of Laser in situ Keratomileusis (LASIK) procedure for the correction of high hypermetropia. Retrospective study of 160 patients (266 eyes) who underwent LASIK procedure for the correction of hypermetropia between +3.00 and +7.00 diopters(D) and cylinder up to 2.00D from January 2013 and August 2015. All ablations were performed with Wavelight Allegretto Eye-Q400Hzexcimer laser (Alcon, Forth Worth, TX, USA) with aberration free module and were centered on a corneal vertex. All flaps were made with Moria M2 (Moria, Antony, France) mechanical microkeratome (90μm head). Preoperative and postoperative uncorrected and corrected distant visual acuity (UDVA, CDVA), spherical equivalent (SE) and a berrometry for 5mm pupil were measured. Measurements were taken at 1 week, 1,3,6 and 12 months after the surgery. Wilcoxon Signed Ranks Test was used for statistical analysis. Postoperative UDVA was lower than preoperative CDVA at 1 week(p=0.001), at 1 month there was no difference (p=0.099), and at 3,6 and 12 months UDVA was better (p<0.0001). Preoperative SE was 4.69±1.20D (+3.75 to +7.50D). At 1 week SE was 0.03±0.67D (-0.50 to +0.63D), while at 1 year regressed to 0.58±0.56D (+0.25 to +0.88D). Sphere shifted from negative values targeted in treatment planning to compensate for regression to positive values. There was significant difference in SE at every time point (p<0.0005). There was a significant increase in coma (p<0.0001), trefoil (p<0.0001, p=0.0006) and spherical aberration (p=0.022, p=0.0052) at 1 week and 1 month postoperatively, without change throughout the rest of follow up. LASIK for high hypermetropia showed satisfactory results in postoperative refraction with reasonable regression without significant loss of lines of visual acuity. However, more test are necessary to asses optical quality.