Zhenan Jiang

Zhenan Jiang

Auto-generated profile, based on publicly available information

Zhenan Jiang

Victoria University of Wellington

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
ZJZhenan Jiang
Zhenan Jiang
KHKent Hamilton
Kent Hamilton
NANaoyuki Amemiya
Naoyuki Amemiya
RBRodney Badcock
Rodney Badcock
CBC. W. Bumby
C. W. Bumby
Superconducting flux pumps enable large currents to be injected into a superconducting circuit, without the requirement for thermally conducting current leads which bridge between the cryogenic environment and room temperature. In this work, we have built and studied a mechanically rotating flux pump which employs a coated conductor high-Tc superconducting (HTS) stator. This flux pump has been used to excite an HTS double pancake coil at 77 K. Operation of the flux pump causes the current within the superconducting circuit to increase over time, before saturating at a limiting value. Interestingly, the superconducting flux pump is found to possess an effective internal resistance, Reff, which varies linearly with frequency, and is two orders of magnitude larger than the measured series resistance of the soldered contacts within the circuit. This internal resistance sets a limit for the maximum achievable output current from the flux pump, which is independent of the operating frequency. We attribute this effect to dynamic resistance within the superconducting stator wire which is caused by the interaction between the DC transport current and the imposed alternating magnetic field. We provide an analytical expression describing the output characteristics of our rotating flux pump in the high frequency limit, and demonstrate that it describes the time-dependent behavior of our experimental circuit. Dynamic resistance is highlighted as a generic issue that must be considered when optimizing the design of an HTS flux pump.

3 November 2004 in Superconductor Science and Technology
Verified
Journal Article
Closed access
NANaoyuki Amemiya
Naoyuki Amemiya
SKSatoshi Kasai
Satoshi Kasai
KYKeiji Yoda
Keiji Yoda
ZJZhenan Jiang
Zhenan Jiang
GLGeorge A Levin
George A Levin
COCharles E Oberly
Charles E Oberly

17 January 2017 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
ZJZhenan Jiang
Zhenan Jiang
RTRyuki Toyomoto
Ryuki Toyomoto
NANaoyuki Amemiya
Naoyuki Amemiya
XZXingyou Zhang
Xingyou Zhang
CBChris W Bumby
Chris W Bumby
Superconducting high- T c coated conductor (CC) wires comprise a ceramic thin film with a large aspect ratio. This geometry can lead to significant dissipative losses when exposed to an alternating magnetic field. Here we report experimental measurements of the ‘dynamic resistance’ of commercially available SuperPower and Fujikura CC wires in an AC perpendicular field. The onset of dynamic resistance occurs at a threshold field amplitude, which is determined by the total DC transport current and the penetration field of the conductor. We show that the field-dependence of the normalised magnetisation loss provides an unambiguous value for this threshold field at zero transport current. From this insight we then obtain an expression for the dynamic resistance in perpendicular field. This approach implies a linear relationship between dynamic resistance and applied field amplitude, and also between threshold field and transport current and this is consistent with our experimental data. The analytical expression obtained yields values that closely agree with measurements obtained across a wide range of frequencies and transport currents, and for multiple CC wires produced by different wire manufacturers and with significantly differing dimensions and critical currents. We further show that at high transport currents, the measured DC resistance includes an additional nonlinear term which is due to flux-flow resistance incurred by the DC transport current. This occurs once the field-dependent critical current of the wire falls below the DC transport current for part of each field cycle. Our results provide an effective and simple approach to calculating the dynamic resistance of a CC wire, at current and field magnitudes consistent with those expected in superconducting machines.

12 January 2016 in Superconductor Science and Technology
Verified
Journal Article
Open access
PDF file
CBChris W Bumby
Chris W Bumby
RBRodney Badcock
Rodney Badcock
HSHae-Jin Sung
Hae-Jin Sung
KKKwang-Min Kim
Kwang-Min Kim
ZJZhenan Jiang
Zhenan Jiang
RBRobert G Buckley
Robert G Buckley
HTS synchronous generators, in which the rotor coils are wound from high-T c superconducting wire, are exciting attention due to their potential to deliver very high torque and power densities. However, injection of the large DC currents required by the HTS rotor coils presents a technical challenge. In this paper we discuss the development of a brushless HTS exciter which operates across the cryostat wall to inject a superconducting DC current into the rotor coil circuit. This approach fundamentally alters the thermal load upon the cryogenic system by removing the need for thermally inefficient normal-conducting current leads. We report results from an experimental laboratory device and show that it operates as a constant voltage source with an effective internal resistance. We then discuss the design of a prototype HTS-PM exciter based on our experimental device, and describe its integration with a demonstration HTS generator. This 200 RPM, 10 kW synchronous generator comprises eight double pancake HTS rotor coils which are operated at 30 K, and are energised to 1.5 T field through the injection of 85 A per pole. We show how this excitation can be achieved using an HTS-PM exciter consisting of 12 stator poles of 12 mm YBCO coated-conductor wire and an external permanent magnet rotor. We demonstrate that such an exciter can excite the rotor windings of this generator without forming a thermal-bridge across the cryostat wall. Finally, we provide estimates of the thermal load imposed by our prototype HTS-PM exciter on the rotor cryostat. We show that duty cycle operation of the device ensures that this heat load can be minimised, and that it is substantially lower than that of equivalently-rated conventional current leads.

6 June 2018 in Superconductor Science and Technology
Verified
Journal Article
Open access
PDF file
MAMark D Ainslie
Mark D Ainslie
CBChris W Bumby
Chris W Bumby
ZJZhenan Jiang
Zhenan Jiang
RTRyuki Toyomoto
Ryuki Toyomoto
NANaoyuki Amemiya
Naoyuki Amemiya

25 September 2015 in Superconductor Science and Technology
Verified
Journal Article
Closed access
ZJZhenan Jiang
Zhenan Jiang
CBChris W Bumby
Chris W Bumby
RBRodney Badcock
Rodney Badcock
HSHae-Jin Sung
Hae-Jin Sung
NLNicholas Long
Nicholas Long
NANaoyuki Amemiya
Naoyuki Amemiya
HTS flux pumps enable superconducting currents to be directly injected into a magnet coil without the requirement for thermally inefficient current leads. Here, we present results from an experimental mechanically rotating HTS flux pump employing a coated-conductor stator and operated at 77 K. We show the effect of varying the size of the flux gap between the rotor magnets and coated conductor stator from 1 to 7.5 mm. This leads to a corresponding change in the peak applied perpendicular magnetic field at the stator from approximately 350 to 50 mT. We observe that our experimental device ceases to maintain a measurable output at flux gaps above 7.5 mm, which we attribute to the presence of screening currents in the stator wire. We show that our mechanically rotating flux pump is well described by a simple circuit model which enables the output performance to be described using two simple parameters, the open-circuit voltage V oc and the internal resistance, R d . Both of these parameters are found to be directly proportional to magnet-crossing frequency and decrease with increasing flux gap. We show that the trend in R d can be understood by considering the dynamic resistance experienced at the stator due to the oscillating amplitude of the applied rotor field. We adopt a literature model for the dynamic resistance within our coated-conductor stator and show that this gives good agreement with the experimentally measured internal resistance of our flux pump.