Biofilm infections in submillimeter interstices at soft tissue-implant/hard tissue interfaces (infection pockets) pose substantial health risks. Traditional surgical and microrobotic strategies struggle to address biofilms in these multicurvature spaces. Here, we report the bridging effect of microswarm self-assembled from magnetic hydrogel particles to eradicate biofilms in infection pockets. The microswarm dynamically bridges dual surfaces within infection pockets, enabling continuous, stable contact and force delivery across concave, plane, and convex surfaces through optimized thickness and shear force. The synergy of enzymatic degradation and mechanical disruption enhances biofilm eradication efficiency by eightfold compared to mechanical disruption alone. A multifunctional hydrogel filler is further used to remove biofilm debris and inhibit microbial recolonization, eventually achieving >99% biofilm elimination in ex vivo and in vivo models. This strategy uses the bridging effect, shape reconfigurability, and enzymatic-mechanical synergy of microswarm, offering a minimally invasive, site-specific solution for deep-tissue infections and persistent biofilms, with reduced reliance on antibiotics.
Iontronic pressure sensors featuring high sensitivity are promising across different emerging fields. In applications requiring high-fidelity sensing such as surgeries, reliable pressure monitoring necessitates sensitivity and stability at the same time to ensure safety. However, existing iontronic sensors often face a trade-off between them—soft ionic materials with high conductivity often present pronounced viscoelasticity, resulting in a low sensitivity–to–drift-rate ( S/D ) ratio. Here, we report a polyelectrolyte-based iontronic pressure sensor that achieves a nearly one order-of-magnitude improvement in S/D ratio over state-of-the-art designs using a polarity-balance strategy in the polyelectrolyte to simultaneously regulate ionic conductivity and viscoelasticity. The resulting sensor exhibits ultrahigh sensitivity (119.5 per kilopascal) and exceptional stability (drift rate < 1%) under prolonged pressures up to 450 kilopascals, enabling nearly drift-free pressure detection for high-precision surgical operations in both surgeon-operated and robotic-assisted procedures. This work provides an extensible material design strategy to enhance sensitivity while suppressing signal drift in soft pressure sensors, with broad relevance to robotics, medical devices, and wearables.