15 December 2023 in Science Advances
The magnetic microrobots promise benefits in minimally invasive cell-based therapy. However, they generally suffer from an inevitable compromise between their magnetic responsiveness and biomedical functions. Herein, we report a modularized microrobot consisting of magnetic actuation (MA) and cell scaffold (CS) modules. The MA module with strong magnetism and pH-responsive deformability and the CS module with cell loading-release capabilities were fabricated by three-dimensional printing technique. Subsequently, assembly of modules was performed by designing a shaft-hole structure and customizing their relative dimensions, which enabled magnetic navigation in complex environments, while not deteriorating the cellular functionalities. On-demand disassembly at targeted lesion was then realized to facilitate CS module delivery and retrieval of the MA module. Furthermore, the feasibility of proposed system was validated in an in vivo rabbit bile duct. Therefore, this work presents a modular design–based strategy that enables uncompromised fabrication of multifunctional microrobots and stimulates their development for future cell-based therapy.
23 December 2022 in Nature Communications
Miniature magnetic soft machines could significantly impact minimally invasive robotics and biomedical applications. However, most soft machines are limited to solid magnetic materials, whereas further progress also relies on fluidic constructs obtained by reconfiguring liquid magnetic materials, such as ferrofluid. Here we show how harnessing the wettability of ferrofluids allows for controlled reconfigurability and the ability to create versatile soft machines. The ferrofluid droplet exhibits multimodal motions, and a single droplet can be controlled to split into multiple sub-droplets and then re-fuse back on demand. The soft droplet machine can negotiate changing terrains in unstructured environments. In addition, the ferrofluid droplets can be configured as a liquid capsule, enabling cargo delivery; a wireless omnidirectional liquid cilia matrix capable of pumping biofluids; and a wireless liquid skin, allowing multiple types of miniature soft machine construction. This work improves small magnetic soft machines’ achievable complexity and boosts their future biomedical applications capabilities.
10 March 2023 in Science Advances
Electrical stimulation is a promising method to modulate gastrointestinal disorders. However, conventional stimulators need invasive implantation and removal surgeries associated with risks of infection and secondary injuries. Here, we report a battery-free and deformable electronic esophageal stent for wireless stimulation of the lower esophageal sphincter in a noninvasive fashion. The stent consists of an elastic receiver antenna infilled with liquid metal (eutectic gallium-indium), a superelastic nitinol stent skeleton, and a stretchable pulse generator that jointly enables 150% axial elongation and 50% radial compression for transoral delivery through the narrow esophagus. The compliant stent adaptive to the dynamic environment of the esophagus can wirelessly harvest energy through deep tissue. Continuous electrical stimulations delivered by the stent in vivo using pig models significantly increase the pressure of the lower esophageal sphincter. The electronic stent provides a noninvasive platform for bioelectronic therapies in the gastrointestinal tract without the need for open surgery.
23 July 2024 in Nature Materials
24 October 2025 in Science Advances
Endoluminal stent implantation is a common intervention strategy for treating obstructive lesions, but conventional delivery systems struggle to reach deep, tortuous ducts. To overcome this limitation, we present a magnetically controlled microrobot that integrates two functional modules: a magnetic actuation (MA) module for agile navigation and an ultrasound-responsive self-expanding stent module (ST module) for lesion-specific dilation. The system uses a dynamically tunable assembly mechanism governed by rotational direction enabling integrated locomotion (clockwise) and on-demand module separation (counterclockwise) at stenotic sites. The platform is compatible with intraoperative ultrasound, allowing real-time navigation and thermally triggered expansion in physiological environments. By synergizing programmable magnetic actuation, ultrasound-mediated expansion, and clinical workflow compatibility, the robot can navigate tortuous phantom ducts, achieving controlled stent deployment within 3 seconds and complete expansion within 30 seconds, permitting minimally invasive treatment of biliary strictures. This work advances microrobotic stent delivery by overcoming key barriers to clinical translation in endoluminal interventions.
28 March 2025 in Nature Communications
Water surface jumping motions of semi-aquatic insects are primarily rely on surface tension-dominated jumping mechanism to achieve impressive jumping performance. However, this mechanism faces an inherent physical constraint: the propulsion force must remain below the threshold required to break the water surface, limiting efficient momentum acquisition. Herein, we present a water surface jumping strategy that addresses the limitations of surface tension-dominated mechanism. Our approach allows the engineered jumper to achieve a record-breaking jumping height of 18 body lengths (63 cm) and take-off velocity of 100.6 body length/s (3.52 m/s). This strategy is built on three key design principles: (I) superhydrophobic body for floating on water surface, (II) light-weight, high-power actuation module capable of providing significant propulsion force within an ultrashort time, (III) well-engineered momentum transmission system for efficient kinetic energy transfer. The developed soft jumper based on these design principles advances the development of water environment related robotics.