In this study, a distributed multi-channel fiber-optic sensor for simultaneous measurement of relative humidity (RH) and temperature with finer gauge length based on spatial-domain time-delayed multiplexing is proposed and experimentally demonstrated. Simultaneous acquisition of multi-channel signals can be realized by reconfiguring the system layout in a spatial-domain time-delayed multiplexing manner by re-routing the Rayleigh backscattered signals for split-channel processing using only extra delay fibers and couplers instead of any optical switches extending the acquisition time or acquisition unit increasing the system cost. Sensing units comprised of copper (Cu)-coated fiber and polyimide (PI)-coated fiber are used to extract the changes of RH and temperature in the environment simultaneously thanks to the distinct sensitivities on RH and temperature of the two fibers. Experimental results show that the sensing system is able to realize multi-channel simultaneous measurement of RH and temperature with gauge length up to 10 mm. Besides, the system is proved to have excellent stability and reliability in high humidity environments. This novel and simple sensing technique for multi-channel dual-parameter simultaneous measurement will provide new ideas for development of economical, reliable, and practical RH and temperature sensing network.
A low-dose X-ray detector based on a novel Ce 3+ , Tb 3+ and Gd 3+ co-doped YAG crystal-derived scintillation fiber (CTGYCF) was demonstrated. The CTGYCF, featuring an yttrium aluminosilicate glass core and SiO 2 cladding, was prepared using the melt-in-tube (MIT) method. The effective atomic number ( Zeff ) of the CTGYCF core reaches 29.59, and the average insertion loss of the splicing between CTGYCF and commercial transmission quartz fiber (MMF) is 0.013 dB. The CTGYCF exhibits higher luminescence intensity under 245 nm excitation due to efficient energy transfer from Gd 3+ and Ce 3+ to Tb 3+ . Leveraging the CTGYCF’s high Zeff , high optical-yield, and low connection-loss, the detector realized real-time monitoring of low-dose X-ray. For low-dose X-rays in the range of 1.13 to 3.06 μGy/s, the detector demonstrated an excellent linear response with an R² values of ~0.997. Its X-ray response remained highly stable as the dose rate increased from 12.24 to 30.74 μGy/s. Given its performance, the CTGYCF-based detector shows great potential for remote real-time monitoring of low-dose X-ray in inaccessible or hazardous environments.