Dimitra Flouri

Dimitra Flouri

Auto-generated profile, based on publicly available information

Dimitra Flouri

In Silico Modelling Group, Department of Mechanical and Manufacturing Engineering University of Cyprus Nicosia Cyprus

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
DFDimitra Flouri
Dimitra Flouri
DODavid Owen
David Owen
RARosalind Aughwane
Rosalind Aughwane
NMNada Mufti
Nada Mufti
KMKasia Maksym
Kasia Maksym
AMAndrew Melbourne
Andrew Melbourne
Purpose: Motion correction in placental DW‐MRI is challenging due to maternal breathing motion, maternal movements, and rapid intensity changes. Parameter estimates are usually obtained using least‐squares methods for voxel‐wise fitting; however, they typically give noisy estimates due to low signal‐to‐noise ratio. We introduce a model‐driven registration (MDR) technique which incorporates a placenta‐specific signal model into the registration process, and we present a Bayesian approach for Diffusion‐rElaxation Combined Imaging for Detailed placental Evaluation model to obtain individual and population trends in estimated parameters.Methods: MDR exploits the fact that a placenta signal model is available and thus we incorporate it into the registration to generate a series of target images. The proposed registration method is compared to a pre‐existing method used for DCE‐MRI data making use of principal components analysis. The Bayesian shrinkage prior (BSP) method has no user‐defined parameters and therefore measures of parameter variation in a region of interest are determined by the data alone. The MDR method and the Bayesian approach were evaluated on 10 control 4D DW‐MRI singleton placental data.Results: MDR method improves the alignment of placenta data compared to the pre‐existing method. It also shows a further reduction of the residual error between the data and the fit. BSP approach showed higher precision leading to more clearly apparent spatial features in the parameter maps. Placental fetal oxygen saturation (FO2) showed a negative linear correlation with gestational age.Conclusions: The proposed pipeline provides a robust framework for registering DW‐MRI data and analyzing longitudinal changes of placental function.

15 March 2022 in British Journal of Radiology
Verified
Journal Article
Open access
ACAlys Clark
Alys Clark
DFDimitra Flouri
Dimitra Flouri
NMNada Mufti
Nada Mufti
JJJoanna James
Joanna James
ECEleanor Clements
Eleanor Clements
AMAndrew Melbourne
Andrew Melbourne
The placenta is both the literal and metaphorical black box of pregnancy. Measurement of the function of the placenta has the potential to enhance our understanding of this enigmatic organ and serve to support obstetric decision making. Advanced imaging techniques are key to support these measurements. This review summarises emerging imaging technology being used to measure the function of the placenta and new developments in the computational analysis of these data. We address three important examples where functional imaging is supporting our understanding of these conditions: fetal growth restriction, placenta accreta, and twin-twin transfusion syndrome.

28 August 2022 in Advanced Science
Verified
Journal Article
Open access
DFDimitra Flouri
Dimitra Flouri
JDJack R. T. Darby
Jack R. T. Darby
SHStacey L. Holman
Stacey L. Holman
SCSteven K. S. Cho
Steven K. S. Cho
CDCatherine G. Dimasi
Catherine G. Dimasi
JMJanna Morrison
Janna Morrison
Magnetic resonance imaging (MRI) assessment of fetal blood oxygen saturation (SO2) can transform the clinical management of high‐risk pregnancies affected by fetal growth restriction (FGR). Here, a novel MRI method assesses the feasibility of identifying normally grown and FGR fetuses in sheep and is then applied to humans. MRI scans are performed in pregnant ewes at 110 and 140 days (term = 150d) gestation and in pregnant women at 28+3 ± 2+5 weeks to measure feto‐placental SO2. Birth weight is collected and, in sheep, fetal blood SO2 is measured with a blood gas analyzer (BGA). Fetal arterial SO2 measured by BGA predicts fetal birth weight in sheep and distinguishes between fetuses that are normally grown, small for gestational age, and FGR. MRI feto‐placental SO2 in late gestation is related to fetal blood SO2 measured by BGA and body weight. In sheep, MRI feto‐placental SO2 in mid‐gestation is related to fetal SO2 later in gestation. MRI feto‐placental SO2 distinguishes between normally grown and FGR fetuses, as well as distinguishing FGR fetuses with and without normal Doppler in humans. Thus, a multi‐compartment placental MRI model detects low placental SO2 and distinguishes between small hypoxemic fetuses and normally grown fetuses.

1 February 2021 in Placenta
Verified
Journal Article
Open access
DFDimitra Flouri
Dimitra Flouri
JDJack R.T. Darby
Jack R.T. Darby
SHStacey L. Holman
Stacey L. Holman
SPSunthara R. Perumal
Sunthara R. Perumal
ADAnna L. David
Anna L. David
AMAndrew Melbourne
Andrew Melbourne
Novel imaging measurements of placental development are difficult to validate due to the invasive nature of gold-standard procedures. Animal studies have been important in validation of magnetic resonance imaging (MRI) measurements in invasive preclinical studies, as they allow for controlled experiments and analysis of multiple time-points during pregnancy. This study characterises the longitudinal diffusion and perfusion properties of sheep placentomes using MRI, measurements that are required for future validation studies. Pregnant ewes were anaesthetised for a MRI session on a 3T scanner. Placental MRI was used to classify placentomes morphologically into three types based on their shape and size at two gestational ages. To validate classification accuracy, placentome type derived from MRI data were compared with placentome categorisation results after delivery. Diffusion-Weighted MRI and T2-relaxometry were used to measure a broad range of biophysical properties of the placentomes. MRI morphological classification results showed consistent gestational age changes in placentome shape, as supported by post-delivery gold standard data. The mean apparent diffusion coefficient was significantly higher at 110 days gestation than at late gestation (~140 days; term, 150 days). Mean T2 was higher at mid gestation (152.2 ± 58.1 ms) compared to late gestation (127.8 ms ± 52.0). Significantly higher perfusion fraction was measured in late gestation placentomes that also had a significantly higher fractional anisotropy when compared to the earlier gestational age. We report baseline measurements of techniques common in placental MRI for the sheep placenta. These measurements are essential to support future validation measurements of placental MRI techniques.

19 November 2025 in Scientific Data
Verified
Journal Article
Open access
DFDimitra Flouri
Dimitra Flouri
CPChristos-Panagiotis Papanikas
Christos-Panagiotis Papanikas
GMGeorgios C. Manikis
Georgios C. Manikis
EIEleftherios Ioannou
Eleftherios Ioannou
GKGeorgia Karaoli
Georgia Karaoli
VVVasileios Vavourakis
Vasileios Vavourakis
Brain metastases (BM) are a severe complication of multiple primary malignancies and constitute the most frequent tumors of the central nervous system. Clinical imaging plays a crucial role in the management of BMs, serving as an essential tool for accurate diagnosis, effective treatment planning, and systematic follow-up care. However, progress in improving BM diagnosis and treatment is hindered by the limited availability of high-quality, annotated imaging datasets that reflect clinical variability in morphology, treatment planning, and patient characteristics. This study presents a comprehensive longitudinal dataset of 40 patients, including 744 MRI scans (baseline and follow-up), as well as 45 radiotherapy plans and 45 computed tomography scans. Detailed segmentations of 65 BMs are provided, defining three key tumor regions: enhancing tumor, edema, and necrotic core, offering a precise representation of tumor morphology for advanced quantitative analysis. This data-sharing initiative aims to support research efforts in automated BM detection, lesion segmentation, disease assessment, treatment planning, while contributing to the development of pertinent predictive and prognostic tools to enhance clinical decision-making.

23 June 2021 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
DFDimitra Flouri
Dimitra Flouri
DLDaniel Lesnic
Daniel Lesnic
CCConstantina Chrysochou
Constantina Chrysochou
JPJehill Parikh
Jehill Parikh
PTPeter Thelwall
Peter Thelwall
SSSteven P. Sourbron
Steven P. Sourbron
Introduction: Model-driven registration (MDR) is a general approach to remove patient motion in quantitative imaging. In this study, we investigate whether MDR can effectively correct the motion in free-breathing MR renography (MRR). Materials and methods: MDR was generalised to linear tracer-kinetic models and implemented using 2D or 3D free-form deformations (FFD) with multi-resolution and gradient descent optimization. MDR was evaluated using a kidney-mimicking digital reference object (DRO) and free-breathing patient data acquired at high temporal resolution in multi-slice 2D (5 patients) and 3D acquisitions (8 patients). Registration accuracy was assessed using comparison to ground truth DRO, calculating the Hausdorff distance (HD) between ground truth masks with segmentations and visual evaluation of dynamic images, signal-time courses and parametric maps (all data). Results: DRO data showed that the bias and precision of parameter maps after MDR are indistinguishable from motion-free data. MDR led to reduction in HD (HDunregistered = 9.98 ± 9.76, HDregistered = 1.63 ± 0.49). Visual inspection showed that MDR effectively removed motion effects in the dynamic data, leading to a clear improvement in anatomical delineation on parametric maps and a reduction in motion-induced oscillations on signal-time courses. Discussion: MDR provides effective motion correction of MRR in synthetic and patient data. Future work is needed to compare the performance against other more established methods.