Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Sohag University, New Sohag, 82524, Egypt; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Sohag National University, New Sohag, 82524, Egypt
Auto-generated profile, based on publicly available information
Mohamed A. Abdelshakour
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Sohag University, New Sohag, 82524, Egypt; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Sohag National University, New Sohag, 82524, Egypt
Computationally-designed molecular imprinted polymers (MIP) incorporation into electrochemical sensors has many advantages to the performance of the designed sensors. The innovative self-validated ensemble modeling (SVEM) approach is a smart machine learning-based technique that enabled the design of more accurate predictive models utilizing smaller data sets. The novel SVEM experimental design methodology is exploited here exclusively to optimize the composition of four eco-friendly PVC membranes augmented by a computationally designed magnetic molecularly imprinted polymer to quantitatively determine drotaverine hydrochloride in its combined dosage form and human plasma. Besides, the application of hybrid computational simulations such as molecular dynamics and quantum mechanical calculations (MD/QM) is a time-saving and eco-friendly provider for the tailored design of the MIP particles. Here, for the first time, the predictive power of machine learning is assembled with computational simulations to develop four PVC-based sensors decorated by computationally designed MIP particles utilizing four different experimental designs known as central composite, SVEM-LASSO, SVEM-FWD, and SVEM-PFWD. The pioneering Agree approach further assessed the greenness of the analytical methods, proving their eco-friendliness. The proposed sensors showed decent Nernstian responses towards drotaverine hydrochloride in the range of (58.60—59.09 mV/decade) with a linear quantitative range of (1 x 10−7—1 x 10−2 M) and limits of detection in the range of (9.55 x 10−8 – 7.08 x 10−8 M). Moreover, the proposed sensors showed ultimate eco-friendliness and selectivity for their target in its combined dosage form and spiked human plasma. The proposed sensors were validated as per IUPAC recommendations proving their sensitivity and selectivity for drotaverine determination in dosage form and human plasma. This work presents the first ever application of both the innovative SVEM designs and MD/QM simulations in the optimization and fabrication of drotaverine-sensitive and selective MIP-decorated PVC sensors.
Background: Solid phase extraction (SPE) techniques, based on computationally designed magnetic-based multi-targeting molecular imprinted polymer (MT-MIP), combined with UV spectrophotometric approaches provide advantages in the examination of counterfeit samples. Objective: The current work describes an innovative and sustainable methodology for the simultaneous determination of tadalafil (TAD) and dapoxetine hydrochloride (DAP) in aphrodisiac counterfeit products (honey and instant coffee) utilizing SPE exploiting MT-MIP. Additionally, an innovative UV spectrophotometric method capable of resolving TAD in its pharmaceutical binary mixtures with DAP was developed. A novel computational approach was implemented to tailor the synthesis and design of the MT-MIP particles. Methods: We applied a newly developed UV spectrophotometric method which was based on a Fourier self-deconvolution (FSD) method coupled with the isoabsorptive point for determination of TAD and DAP in pharmaceutical dosage form. We also applied an SPE process based on MT-MIP designed particles, assisting in the analysis of both drugs in counterfeit food samples. The SPE process and the UV spectroscopic methodology were assessed regarding their greenness using the pioneering green analytical procedure index (GAPI), analytical greeness including sample preparation (AGREEprep) and AGREE tools. The synthesized MT-MIP particles were characterized by scanning electron microscopy and energy-dispersive x-ray spectroscopy. Results: The suggested spectrophotometric methods revealed a wide linear concentration range of 2–50 µg/mL with lower LODs in the range of 0.604–0.994 µg/mL. Additionally, the suggested method demonstrated the utmost sensitivity and eco-friendliness for their target in its mixed dosage form and counterfeit food products. Conclusion: The SPE process and the developed analytical UV spectroscopic methodology were validated as per the ICH guidelines, and were found to be suitable for overseeing some counterfeiting activities in commercially available honey and instant coffee aphrodisiac products. Highlights: An SPE method based on MT-MIP magnetic-based polymer and a UV spectroscopic method were successfully developed for analysis of TAD and DAP in different matrices.
1 September 2018 in Records of Pharmaceutical and Biomedical Sciences
Water is very essential for the human, animal and agriculture existence. Water supplies are exposed to contamination by different sources from industrial, pharmaceutical, agricultural and natural origins. Traditionally, analytical methods based on gas chromatography or liquid chromatography were used tomonitor water quality. The objective of this research was to monitor some OPPs and OCPs pesticides residues in Ismailia freshwater canal in the three governorates (Ismailia, Port Said and Suez) over a period started from May 2008 to January 2011 by GC using flame photometric detector (FPD) for OPPs and electron capture detector for OCPs pesticides. No OCPs pesticides residues were found in freshwater at quantification level of the GC method, however OPPs pesticides methamidophos (1.97 ngL-1) and ethoprophos (1.73 ngL-1) were detected in freshwater samples collected from Port Said governorate in February 2009.