Alexey G. Nikolaev

Alexey G. Nikolaev

Auto-generated profile, based on publicly available information

Alexey G. Nikolaev

Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk, Russia

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2005 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
AAAndre Anders
Andre Anders
EOE.M. Oks
E.M. Oks
YYYury Yushkov
Yury Yushkov
KSKonstantin Savkin
Konstantin Savkin
IBI.G. Brown
I.G. Brown
ANA.G. Nikolaev
A.G. Nikolaev
The ion current from different cathode materials was measured for 50-500 A of arc current. The ion current normalized by the arc current was found to depend on the cathode material, with values in the range from 5% to 19%. The normalized ion current was generally greater for elements of low cohesive energy. The ion erosion rates were determined from values of ion current and ion charge states, which were previously measured in the same ion source. The absolute ion erosion rates ranged from 16-173 /spl mu/g/C.

1 February 2012 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ANA. G. Nikolaev
A. G. Nikolaev
EOE. M. Oks
E. M. Oks
KSKonstantin Savkin
Konstantin Savkin
YYYury Yushkov
Yury Yushkov
IBI. G. Brown
I. G. Brown
Vacuum arc ion sources have been made and used by a large number of research groups around the world over the past twenty years. The first generation of vacuum arc ion sources (dubbed “Mevva,” for metal vapor vacuum arc) was developed at Lawrence Berkeley National Laboratory in the 1980s. This paper considers the design, performance parameters, and some applications of a new modified version of this kind of source which we have called Mevva-V.Ru. The source produces broad beams of metal ions at an extraction voltage of up to 60 kV and a time-averaged ion beam current in the milliampere range. Here, we describe the Mevva-V.Ru vacuum arc ion source that we have developed at Tomsk and summarize its beam characteristics along with some of the applications to which we have put it. We also describe the source performance using compound cathodes.

1 June 2006 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
VGV. I. Gushenets
V. I. Gushenets
ANA. G. Nikolaev
A. G. Nikolaev
EOE. M. Oks
E. M. Oks
LVL. G. Vintizenko
L. G. Vintizenko
YYYury Yushkov
Yury Yushkov
IBI. G. Brown
I. G. Brown
We describe the design, electronics, and test results of a simple and low-cost time-of-flight ion charge-to-mass analyzer that is suitable for ion source characterization. The method selects a short-time sample of the beam whose charge-to-mass composition is then separated according to ion velocity and detected by a remote Faraday cup. The analyzer is a detachable device that has been used for rapid analysis of charge-to-mass composition of ion beams accelerated by voltages of up to about 100kV .

1 October 1994 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SBS. P. Bugaev
S. P. Bugaev
ANA. G. Nikolaev
A. G. Nikolaev
EOE. M. Oks
E. M. Oks
PSP. M. Schanin
P. M. Schanin
YYYury Yushkov
Yury Yushkov
TITAN is a new type of ion source capable of generating high current, wide aperture beams of gas and metal ions from a broad range of elements: Mg, Al, Ti, Cr, Fe, Co, Ni, Sm, Zn, W, Pb, Ta, Re, Y, C, He, N, Ar, and Xe. A specific feature of the TITAN ion source is the use of two kinds of arc discharges, each with cold cathodes, to produce plasma for ion beam extraction. Metal ions are generated by means of the vacuum arc in the metal vapor formed in cathode spots. Gas ions, on the other hand, are provided by a low-pressure constricted arc discharge. In a pulsed mode of operation the extraction voltage of the source ranges from 10 to 100 kV. The pulsed beam current for gas and metal ions is on the order of 1 A at pulse repetition rates up to 50 pulses per second and pulse duration of ∼400 μs. For dc operation and at an extraction voltage up to 10 kV, the ion current is as high as hundreds of milliamperes. This work outlines briefly the ion source, its design, and certain physical peculiarities observed when a high current ion beam is generated and transported.

5 December 2014 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
ANA. G. Nikolaev
A. G. Nikolaev
EOE. M. Oks
E. M. Oks
KSKonstantin Savkin
Konstantin Savkin
YYYury Yushkov
Yury Yushkov
VFV. P. Frolova
V. P. Frolova
SBS. A. Barengolts
S. A. Barengolts
We present research results on vacuum arc plasma produced with multicomponent cathode made of several different elements. The ion mass-to-charge-state spectra of the plasmas were studied by time-of-flight spectrometry. The angular distributions of different ion species were measured, and the kinetic energy of their directed (streaming) motion was determined. It is shown that the fractional composition of ions of different cathode components in the plasma flow from the cathode spot closely matches the fractional content of these components in the composite cathode. The charge states of ions of the various cathode components are determined by the average electron temperature in the cathode spot plasma. The angular distribution of lower mass ions in the plasma from a multicomponent cathode is less isotropic and broader than for the plasma from a single-component cathode of the same light element. The directed kinetic energies of the ions of the different components for plasma from a multicomponent cathode are lower for lighter elements and greater for heavier elements compared to the ion directed energy for plasmas from single-component cathodes made of the same materials. The physical processes responsible for these changes in the ion charge states in multicomponent-cathode vacuum arc plasma are discussed.

1 February 2010 in Review of Scientific Instruments
Verified
Journal Article
Closed access
KSKonstantin Savkin
Konstantin Savkin
YYYu. G. Yushkov
Yu. G. Yushkov
ANA. G. Nikolaev
A. G. Nikolaev
EOE. M. Oks
E. M. Oks
YYYury Yushkov
Yury Yushkov
This paper presents the results of time-of-flight mass spectrometry studies of the elemental and mass-to-charge state compositions of metal ion beams produced by a vacuum arc ion source with compound cathode (WC–Co0.5, Cu–Cr0.25, Ti–Cu0.1). We found that the ion beam composition agrees well with the stoichiometric composition of the cathode material from which the beam is derived, and the maximum ion charge state of the different plasma components is determined by the ionization capability of electrons within the cathode spot plasma, which is common to all components. The beam mass-to-charge state spectrum from a compound cathode features a greater fraction of multiply charged ions for those materials with lower electron temperature in the vacuum arc cathode spot, and a smaller fraction for those with higher electron temperature within the spot. We propose a potential diagram method for determination of attainable ion charge states for all components of the compound cathodes.