Sapto Nisworo

Sapto Nisworo

Auto-generated profile, based on publicly available information

Sapto Nisworo

Universitas Tidar

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2023 in Bulletin of Electrical Engineering and Informatics
Verified
Journal Article
Open access
PDF file
HSHabib Satria
Habib Satria
SNSapto Nisworo
Sapto Nisworo
JWJaka Windarta
Jaka Windarta
RSRahmad B.Y Syah
Rahmad B.Y Syah
Utilization of elevation angles and azimuth angles is a very important part in maximizing solar energy into electrical energy in photovoltaic (PV). One way to maximize PV power output is to design a single axis tracker system and take into account the azimuth and elevation angles of the sun using the sun position calculator application. The single axis tracker system is set based on the position of the angle of inclination of the surface of the PV 45°, then the angle of 90° and the angle of inclination of 135°. The test results show that the single axis tracker PV system design can work based on the angle settings that have been programmed. Then the use of a battery control system to support the PV reliability system automatically cuts off electricity when the battery voltage drops below 12 V during cloudy weather conditions and excessive battery usage. The integration of the PZEM-017 module with the battery will support monitoring of battery power usage in real time. PV energy data conversion performance uses single axis tracker technology for maximum power reaching 631.72 Watt DC at 12.00 pm and the lowest power reaching 56.02 Watt DC at 6.00 pm.

1 December 2024 in International Journal of Applied Power Engineering (IJAPE)
Verified
Journal Article
Open access
PDF file
SNSapto Nisworo
Sapto Nisworo
AHArnawan Hasibuan
Arnawan Hasibuan
MIMuzamir Isa
Muzamir Isa
INI Made Ari Nrartha
I Made Ari Nrartha
MJMisbahul Jannah
Misbahul Jannah
MMMuhammad Muhammad
Muhammad Muhammad
Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.

1 October 2015
Verified
Conference Paper
Closed access
SNSapto Nisworo
Sapto Nisworo
HBHamzah Berahim
Hamzah Berahim
TUTumiran
Tumiran
SUSuharyanto
Suharyanto
The quality of electrical power basically is all issues relating to the electrical power, including deviation of the normal condition of voltage, current and frequency. The electronic equipment currently used in households generate significant current harmonic distortion. The objective of this research is to map and reduce the harmonic distortion on household electricity customers 450 VA and 900 VA. This research was conducted in several areas in Magelang City, Temanggung Regency, Purworejo Regency, Salatiga City, Karanganyar Regency, Banjarnegara Regency, Semarang Regency and Pekalongan Regency of Central Java randomly, using loads that are used for daily household. The average percentage of THDi for an installed power of 900 VA is 37.94 percent, while customers with 450 VA percentage of THDi is 49.84 percent. A group of households in a network with industry, the average percentage of THDi of installed power capacity of 900 VA is 38.94 percent and for the customer with 450VA has percentage THDi value of 41.29 percent. The results of measurement, percentage THDi on household electricity customers, then performed a simulation with PSIM software. Electric power source used and load voltage 220 V household appliances analogous to a full wave rectifier with resistive load of 100 ohms and 28 uF capacitor. Passive filter used is the type LLCL. The simulation resulted from using LLCL filter tuned to the harmonic order 3 with a frequency of 150 Hz to get a reduction of percentage THDi from 45.6204 percent dropped to 9.1444 percent with 16 volt voltage drop.

17 April 2023 in ULIL ALBAB : Jurnal Ilmiah Multidisiplin
Verified
Journal Article
Open access
PDF file
MAMuhammad Amrullah
Muhammad Amrullah
DPDeria Pravitasari
Deria Pravitasari
SNSapto Nisworo
Sapto Nisworo
One way to reduce carbon dioxide emissions from power plants powered by fossil fuels is by utilizing new renewable energy sources to generate the electrical energy needed each day. The Faculty of Engineering 03 UNTIDAR Building has a roof area of 997.4 m2 and a solar irradiation potential of 4.89 kWh/m2 per day, so it is very probable to build a rooftop PLTS to supply the building's lighting demand. Therefore, a plan for installing a rooftop PLTS system was implemented in this study in order to contribute to the utilization of new, renewable energy and the reduction of carbon dioxide emissions. The method employed in this planning is descriptive analysis, which includes analyses of the locations for installing solar modules, the building's daily electricity usage, the technical design of the rooftop PLTS system, analyses of the energy produced, and analyses of the potential to lower carbon dioxide emissions. According to the planning results, the rooftop PLTS has a capacity of 124 kWp and can generate 135,299,299.29 kWh of electrical energy annually utilizing 231 units of 540 W solar modules that are divided into 10 strings. 8,267.97 kWh are typically exported each month to PT. PLN as electrical energy. While the potential reduction in carbon dioxide emissions is calculated to be 135,299.29 tons of CO2 annually.

30 September 2022 in Journal of Renewable Energy, Electrical, and Computer Engineering
Verified
Journal Article
Open access
PDF file
SNSapto Nisworo
Sapto Nisworo
DPDeria Pravitasari
Deria Pravitasari
ZKZulfikar Aji Kusworo
Zulfikar Aji Kusworo
AAAshari Ashari
Ashari Ashari
NKNaseer A Khan
Naseer A Khan
The focus of this research is to utilize wind energy for power generation as an electric power service for shrimp farming in the Kulon Progo district of Yogyakarta. This is done in order to minimize the use of diesel fuel in daily operations to drive the aerator pump that produces air bubbles and needs lighting. The method used is to calculate the need for electrical power in 24 hours, plan the windmill according to the local average wind speed. Parameters for measuring the final result are net present cost (NPC), cost of energy (CoE), and payback period. The scenario is used by installing a wind power generator compared to a generator from a diesel engine. The results of the study with a wind power generation system capable of producing 41755,07kW/year of power with the NPC value having a more efficient economic value of Rp. 158,254,000.00, a more efficient CoE value of Rp. 477.41, and for a diesel power plant of Rp. 1,569,015,240.00 and CoE worth Rp5,867,45. The payback period for the scenario with wind power is 3 years and 9 months and and 15 years 7 months for the scenario with diesel power plants.

13 May 2023 in PROtek : Jurnal Ilmiah Teknik Elektro
Verified
Journal Article
Open access
PDF file
SNSapto Nisworo
Sapto Nisworo
DPDeria Pravitasari
Deria Pravitasari
IWIis Hamsir Ayub Wahab
Iis Hamsir Ayub Wahab
The focus of this research is optimizing a wind power plant using a Permanent Magnet Synchronous Generator (PMSG). The backpropagation method of the artificial neural network system was chosen to optimize the output power of the wind power generator. Based on the simulation results, the backpropagation algorithm of the artificial neural network obtains the output power based on the input variable in the form of changing wind speed. The results show that the best value is learning rate = 0.5, error = 0.0001, max. epoch= 100000, neuron hidden layer = 5. The Mean Square Error (MSE) value obtained is 0.1026 reaching the goal at epoch 14845. The reverse training regretion reaches 0.99917. The optimization results are close to the specified error, which is 0.0001, while what is obtained is 0.0145. The power generated by the wind speed is 10.7 m/s before being optimized using the back propagation neural network method worth 321 watts, while the optimized power results are 409 watts. The difference in the average target power obtained is 88 watts compared to the power of the Artificial Neural Network (ANN).