1 December 2023 in Bulletin of Electrical Engineering and Informatics
Utilization of elevation angles and azimuth angles is a very important part in maximizing solar energy into electrical energy in photovoltaic (PV). One way to maximize PV power output is to design a single axis tracker system and take into account the azimuth and elevation angles of the sun using the sun position calculator application. The single axis tracker system is set based on the position of the angle of inclination of the surface of the PV 45°, then the angle of 90° and the angle of inclination of 135°. The test results show that the single axis tracker PV system design can work based on the angle settings that have been programmed. Then the use of a battery control system to support the PV reliability system automatically cuts off electricity when the battery voltage drops below 12 V during cloudy weather conditions and excessive battery usage. The integration of the PZEM-017 module with the battery will support monitoring of battery power usage in real time. PV energy data conversion performance uses single axis tracker technology for maximum power reaching 631.72 Watt DC at 12.00 pm and the lowest power reaching 56.02 Watt DC at 6.00 pm.
1 December 2024 in International Journal of Applied Power Engineering (IJAPE)
Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.
17 April 2023 in ULIL ALBAB : Jurnal Ilmiah Multidisiplin
One way to reduce carbon dioxide emissions from power plants powered by fossil fuels is by utilizing new renewable energy sources to generate the electrical energy needed each day. The Faculty of Engineering 03 UNTIDAR Building has a roof area of 997.4 m2 and a solar irradiation potential of 4.89 kWh/m2 per day, so it is very probable to build a rooftop PLTS to supply the building's lighting demand. Therefore, a plan for installing a rooftop PLTS system was implemented in this study in order to contribute to the utilization of new, renewable energy and the reduction of carbon dioxide emissions. The method employed in this planning is descriptive analysis, which includes analyses of the locations for installing solar modules, the building's daily electricity usage, the technical design of the rooftop PLTS system, analyses of the energy produced, and analyses of the potential to lower carbon dioxide emissions. According to the planning results, the rooftop PLTS has a capacity of 124 kWp and can generate 135,299,299.29 kWh of electrical energy annually utilizing 231 units of 540 W solar modules that are divided into 10 strings. 8,267.97 kWh are typically exported each month to PT. PLN as electrical energy. While the potential reduction in carbon dioxide emissions is calculated to be 135,299.29 tons of CO2 annually.
30 September 2022 in Journal of Renewable Energy, Electrical, and Computer Engineering
The focus of this research is to utilize wind energy for power generation as an electric power service for shrimp farming in the Kulon Progo district of Yogyakarta. This is done in order to minimize the use of diesel fuel in daily operations to drive the aerator pump that produces air bubbles and needs lighting. The method used is to calculate the need for electrical power in 24 hours, plan the windmill according to the local average wind speed. Parameters for measuring the final result are net present cost (NPC), cost of energy (CoE), and payback period. The scenario is used by installing a wind power generator compared to a generator from a diesel engine. The results of the study with a wind power generation system capable of producing 41755,07kW/year of power with the NPC value having a more efficient economic value of Rp. 158,254,000.00, a more efficient CoE value of Rp. 477.41, and for a diesel power plant of Rp. 1,569,015,240.00 and CoE worth Rp5,867,45. The payback period for the scenario with wind power is 3 years and 9 months and and 15 years 7 months for the scenario with diesel power plants.
13 May 2023 in PROtek : Jurnal Ilmiah Teknik Elektro
The focus of this research is optimizing a wind power plant using a Permanent Magnet Synchronous Generator (PMSG). The backpropagation method of the artificial neural network system was chosen to optimize the output power of the wind power generator. Based on the simulation results, the backpropagation algorithm of the artificial neural network obtains the output power based on the input variable in the form of changing wind speed. The results show that the best value is learning rate = 0.5, error = 0.0001, max. epoch= 100000, neuron hidden layer = 5. The Mean Square Error (MSE) value obtained is 0.1026 reaching the goal at epoch 14845. The reverse training regretion reaches 0.99917. The optimization results are close to the specified error, which is 0.0001, while what is obtained is 0.0145. The power generated by the wind speed is 10.7 m/s before being optimized using the back propagation neural network method worth 321 watts, while the optimized power results are 409 watts. The difference in the average target power obtained is 88 watts compared to the power of the Artificial Neural Network (ANN).