Yuan Wu

Yuan Wu

Auto-generated profile, based on publicly available information

Yuan Wu

Refractive Surgery Department, Shanxi Aier Eye Hospital, Taiyuan, People’s Republic of China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
YWYuan Wu
Yuan Wu
SWShuhan Wang
Shuhan Wang
GWGuiqin Wang
Guiqin Wang
SZShaozhen Zhao
Shaozhen Zhao
RWRuihua Wei
Ruihua Wei
YHYue Huang
Yue Huang
Objective . To compare the corneal asphericity and higher‐order aberrations (HOAs) of femtosecond laser‐assisted in situ keratomileusis (FS‐LASIK) with Smart Pulse Technology (SPT) assisted transepithelial photorefractive keratectomy (Trans‐PRK) for myopia and myopic astigmatism correction. Methods . This prospective study analyzed 88 eyes of 44 patients treated with FS‐LASIK and 64 eyes of 32 patients treated with Trans‐PRK. All eyes had low to moderate myopia with or without astigmatism (spherical equivalent (SE) <−6.00 diopters). The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), SE, asphericity ( Q value) of the anterior corneal surface, index of surface variance (ISV), corneal higher‐order aberrations (HOAs), vertical coma (Z 3 −1 ), horizontal coma (Z 3 1 ), and spherical aberration ( Z 4 0 ) over a 6 mm diameter central corneal zone diameter were evaluated preoperatively and 1, 3, and 6 months postoperatively. Results . At 6 months, the UDVA and SE were −0.14 ± 0.06 and 0.33 ± 0.33D in FS‐LASIK and −0.15 ± 0.06 and 0.35 ± 0.37D in Trans‐PRK. There was no difference between the two groups in the postoperative UDVA and SE ( P > 0.05). After FS‐LASIK and Trans‐PRK, the Q values in the 6, 7, 8, and 9 mm zones and ISV of the anterior corneal surface significantly increased ( P < 0.001). At 1, 3, and 6 months after surgery, corneal HOA, Z 3 -1 , Z 3 1 , and Z 4 0 in both groups were significantly increased compared with those before surgery, with statistically significant differences ( P < 0.001). At 1, 3, and 6 months after surgery, the Z 3 −1 of the Trans‐PRK group was significantly lower than that of the FS‐LASIK group ( P < 0.001). ΔHOA and ΔZ 4 0 were dramatically correlated with the ΔQ value for both FS‐LASIK and Trans‐PRK procedures. The ΔQ was significantly correlated with the preoperative SE, AD, and AD/CCT after both two procedures (all P < 0.001). Conclusions . Both FS‐LASIK and Trans‐PRK caused the anterior corneal surface to become flatter, and the morphology of the corneal surface was irregular. Corneal HOAs were significantly increased after the two procedures. Trans‐PRK using SPT introduced less corneal vertical coma than FS‐LASIK. Corneal asphericity changes contributed to the corneal aberrations changes following FS‐LASIK and Trans‐PRK.

1 September 2026 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
PHPengfei Han
Pengfei Han
PCPeng Chen
Peng Chen
XFXiaolong Fang
Xiaolong Fang
HQHongwei Qin
Hongwei Qin
YWYuan Wu
Yuan Wu
QZQizhi Zhou
Qizhi Zhou
Purpose: Direction-dependent mechanical behavior exists in the human corneal stroma, but fixed-axis biomechanical testing may be influenced by preoperative astigmatic direction. This study evaluated whether corneal astigmatic direction, a routinely measurable clinical phenotype, corresponds to superior–inferior (SI) vs nasal–temporal (NT) mechanical anisotropy in human stromal lenticules obtained during small-incision lenticule extraction (SMILE). Patients and Methods: Fifty-three spherical stromal lenticules with a programmed cylinder correction of 0 diopters were prospectively collected. Preoperative anterior corneal astigmatism was classified as with-the-rule (WTR) or against-the-rule (ATR), and the steep-axis information was decomposed into a vertical–horizontal component matched to the SI–NT mechanical testing coordinates. Equibiaxial testing was performed along the SI and NT axes, and tangent moduli were calculated at 0.03 MPa. The signed meridional difference index (MDI) was defined as ESI − ENT. Results: WTR lenticules predominantly showed higher SI modulus, whereas ATR lenticules predominantly showed higher NT modulus. The vertical–horizontal astigmatic component was strongly correlated with signed MDI (Spearman rho = 0.875, P < 0.001), and this association remained significant after multivariable adjustment (β = 0.673 MPa/diopter, 95% CI 0.537– 0.809, P < 0.001). Corneal astigmatism magnitude was also associated with direction-independent anisotropy magnitude. Conclusion: Preoperative corneal astigmatic direction may be a clinically measurable stratification variable for interpreting fixed-axis stromal mechanical anisotropy measurements in SMILE-derived lenticules. These findings support incorporating directional clinical phenotypes into corneal biomechanical research and patient-specific modeling, while requiring validation in larger independent samples.