John Maidens

John Maidens

Auto-generated profile, based on publicly available information

John Maidens

Department of Electrical Engineering & Computer Sciences University of California 253 Cory Hall 94720 Berkeley Berkeley CA USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2013 in Automatica
Verified
Journal Article
Closed access
JMJohn N. Maidens
John N. Maidens
SKShahab Kaynama
Shahab Kaynama
IMIan M. Mitchell
Ian M. Mitchell
MOMeeko M.K. Oishi
Meeko M.K. Oishi
GDGuy Dumont
Guy Dumont

4 May 2021 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
JCJohn S. Chorba
John S. Chorba
ASAvi M. Shapiro
Avi M. Shapiro
LLLe Le
Le Le
JMJohn Maidens
John Maidens
JPJohn Prince
John Prince
JTJames D. Thomas
James D. Thomas
Background: Clinicians vary markedly in their ability to detect murmurs during cardiac auscultation and identify the underlying pathological features. Deep learning approaches have shown promise in medicine by transforming collected data into clinically significant information. The objective of this research is to assess the performance of a deep learning algorithm to detect murmurs and clinically significant valvular heart disease using recordings from a commercial digital stethoscope platform. Methods and Results: Using >34 hours of previously acquired and annotated heart sound recordings, we trained a deep neural network to detect murmurs. To test the algorithm, we enrolled 962 patients in a clinical study and collected recordings at the 4 primary auscultation locations. Ground truth was established using patient echocardiograms and annotations by 3 expert cardiologists. Algorithm performance for detecting murmurs has sensitivity and specificity of 76.3% and 91.4%, respectively. By omitting softer murmurs, those with grade 1 intensity, sensitivity increased to 90.0%. Application of the algorithm at the appropriate anatomic auscultation location detected moderate‐to‐severe or greater aortic stenosis, with sensitivity of 93.2% and specificity of 86.0%, and moderate‐to‐severe or greater mitral regurgitation, with sensitivity of 66.2% and specificity of 94.6%. Conclusions: The deep learning algorithm’s ability to detect murmurs and clinically significant aortic stenosis and mitral regurgitation is comparable to expert cardiologists based on the annotated subset of our database. The findings suggest that such algorithms would have utility as front‐line clinical support tools to aid clinicians in screening for cardiac murmurs caused by valvular heart disease. Registration: URL: https://clinicaltrials.gov ; Unique Identifier: NCT03458806.

19 September 2018 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
PLPeder Larson
Peder Larson
HCHsin-Yu Chen
Hsin-Yu Chen
JGJeremy W. Gordon
Jeremy W. Gordon
NKNatalie Korn
Natalie Korn
JMJohn Maidens
John Maidens
DVDaniel B. Vigneron
Daniel B. Vigneron

19 May 2014 in IEEE Transactions on Automatic Control
Verified
Journal Article
Closed access
JMJohn Maidens
John Maidens
MAMurat Arcak
Murat Arcak
Matrix measures, also known as logarithmic norms, have historically been used to provide bounds on the divergence of trajectories of a system of ordinary differential equations. In this technical note we use them to compute guaranteed overapproximations of reachable sets for nonlinear continuous-time systems using numerically simulated trajectories and to bound the accumulation of numerical simulation errors along simulation traces. Our method employs a user-supplied bound on the matrix measure of the system's Jacobian matrix to compute bounds on the behavior of nearby trajectories, leading to efficient computation of reachable sets when such bounds are available. We demonstrate that the proposed technique scales well to systems with a large number of states.

17 October 2023 in Journal of the American Heart Association
Verified
Journal Article
Open access
JPJohn Prince
John Prince
JMJohn Maidens
John Maidens
SKSpencer Kieu
Spencer Kieu
CCCaroline Currie
Caroline Currie
DBDaniel Barbosa
Daniel Barbosa
SVSubramaniam Venkatraman
Subramaniam Venkatraman
Background: The success of cardiac auscultation varies widely among medical professionals, which can lead to missed treatments for structural heart disease. Applying machine learning to cardiac auscultation could address this problem, but despite recent interest, few algorithms have been brought to clinical practice. We evaluated a novel suite of Food and Drug Administration‐cleared algorithms trained via deep learning on >15 000 heart sound recordings. Methods and Results: We validated the algorithms on a data set of 2375 recordings from 615 unique subjects. This data set was collected in real clinical environments using commercially available digital stethoscopes, annotated by board‐certified cardiologists, and paired with echocardiograms as the gold standard. To model the algorithm in clinical practice, we compared its performance against 10 clinicians on a subset of the validation database. Our algorithm reliably detected structural murmurs with a sensitivity of 85.6% and specificity of 84.4%. When limiting the analysis to clearly audible murmurs in adults, performance improved to a sensitivity of 97.9% and specificity of 90.6%. The algorithm also reported timing within the cardiac cycle, differentiating between systolic and diastolic murmurs. Despite optimizing acoustics for the clinicians, the algorithm substantially outperformed the clinicians (average clinician accuracy, 77.9%; algorithm accuracy, 84.7%.) Conclusions: The algorithms accurately identified murmurs associated with structural heart disease. Our results illustrate a marked contrast between the consistency of the algorithm and the substantial interobserver variability of clinicians. Our results suggest that adopting machine learning algorithms into clinical practice could improve the detection of structural heart disease to facilitate patient care.

17 April 2012
Verified
Conference Paper
Open access
PDF file
SKShahab Kaynama
Shahab Kaynama
JMJohn Maidens
John Maidens
MOMeeko Oishi
Meeko Oishi
IMIan M. Mitchell
Ian M. Mitchell
GDGuy Dumont
Guy Dumont
We present a connection between the viability kernel and maximal reachable sets. Current numerical schemes that compute the viability kernel suffer from a complexity that is exponential in the dimension of the state space. In contrast, extremely efficient and scalable techniques are available that compute maximal reachable sets. We show that under certain conditions these techniques can be used to conservatively approximate the viability kernel for possibly high-dimensional systems. We demonstrate the results on two practical examples, one of which is a seven-dimensional problem of safety in anesthesia.