Ana Prates Soares

Ana Prates Soares

Auto-generated profile, based on publicly available information

Ana Prates Soares

Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2022 in Acta Biomaterialia
Verified
Journal Article
Open access
AKAlexander Kopp
Alexander Kopp
HFHeilwig Fischer
Heilwig Fischer
ASAna Prates Soares
Ana Prates Soares
KSKatharina Schmidt-Bleek
Katharina Schmidt-Bleek
CLChristoph Leber
Christoph Leber
CRCarsten Rendenbach
Carsten Rendenbach
Bioabsorbable magnesium implants for orthopedic fixation of bone have recently become available for different fields of indication. While general questions of biocompatibility have been answered, tailoring suitable degradation kinetics for specific applications as well as long-term tissue integration remain the focus of current research. The aim of this study was the evaluation of the long-term degradation behavior and osseointegration of Mg-Ca-Zn (ZX00MEO) based magnesium implants with plasma-electrolytic oxidation (PEO) surface modification (ZX00MEO-PEO) in comparison to non-surface modified implants in vivo and in vitro. Besides a general evaluation of the biological performance of the alloy over a prolonged period, the main hypothesis was that PEO surface modification significantly reduces implant degradation rate and improves tissue interaction. In vitro, the microstructure and surface of the bioabsorbable screws were characterized by SEM/EDS, cytocompatibility and degradation testing facilitating hydrogen gas evolution, carried out following ISO 10993-5/-12 and ASTM F3268-18a/ASTM G1-03 (E1:2017). In vivo, screws were implanted in the frontal bone of Minipigs for 6, 12, and 18 months, following radiological and histomorphometric analysis. A slower and more uniform degradation and improved cytocompatibility could be shown for the ZX00MEO-PEO group in vitro. A significant reduction of degradation rate and enhanced bone formation around the ZX00MEO-PEO screws in vivo was confirmed. Proficient biocompatibility and tissue integration could generally be shown in vivo regardless of surface state. The tested magnesium alloy shows generally beneficial properties as an implant material, while PEO-surface modification further improves the bioabsorption behavior both in vitro and in vivo. STATEMENT OF SIGNIFICANCE: Devices from bioabsorbable Magnesium have recently been introduced to orthopedic applications. However, the vast degradation of Magnesium within the human body still gives limitations. While reliable in-vivo data on most promising surface treatments such as Plasma-electrolytic-Oxidation is generally scarce, long-time results in large animals are to this date completely missing. To overcome this lack of evidence, we studied a Magnesium-Calzium-Zinc-alloy with surface enhancement by PEO for the first time ever over a period of 18 months in a large animal model. In-vitro, surface-modified screws showed significantly improved cytocompatibility and reduction of degradation confirmed by hydrogen gas evolution testing, while in-vivo radiological and histological evaluation generally showed good biocompatibility and bioabsorption as well as significantly enhanced reduction of degradation and faster bone regeneration in the PEO-surface-modified group.

8 June 2020 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
HMHawshan Abdulrahman Mustafa
Hawshan Abdulrahman Mustafa
ASAna Prates Soares
Ana Prates Soares
SPSebastian Paris
Sebastian Paris
KEKarim Elhennawy
Karim Elhennawy
PZPaul Zaslansky
Paul Zaslansky
Objective: To reevaluate proven strengths and weakness of glass ionomer cements (GICs) and to identify agreement versus conflicting evidence in previous reports regarding the transition between GIC and the tooth, and the existence of an “interphase”. Materials and methods: Relevant electronic databases (PubMed, Embase via Ovid and Medline via Web of science) were searched for publications of evidence relating to the transition zone at the GIC-tooth interphase. Studies were examined and grouped according to characteristics of GIC-tooth attachment area quantified by X-ray and optical microscopy techniques in 2D and 3D. Results: Inclusion criteria comprised of in vitro studies that showed images of the conventional GIC-tooth substrate attachments using at least one of the following techniques: SEM, CLSM, or μCT. The search identified 419 studies, from which 33 were included. Ten studies demonstrated the existence of an interphase layer and five studies quantified the layer thickness (1–15 μ). Twenty-nine publications studied different failure modes of the GIC-tooth interphase. Eleven studies described discontinuities inside the GIC bulk. Conclusion: The GIC-tooth interphase attributes evolve with time. Good attachment is evident even under compromised surface preparation. The GIC-tooth attachment area is resistant to acidic dissolution as compared to both tooth and GIC bulk. In general, studies revealed mostly intact GIC-tooth interphases with only some cracked interphases. Clinical significance: GIC bonds to the tooth structure and forms an acid resistant attachment zone that might enhance caries inhibition. Due to fluoride release and ease of use, GIC provides a cost effective treatment, ideal for low income or high caries populations.

17 March 2023 in Frontiers in Physiology
Verified
Journal Article
Open access
ASAna Prates Soares
Ana Prates Soares
HFHeilwig Fischer
Heilwig Fischer
SASabrin Aydin
Sabrin Aydin
CSClaudius Steffen
Claudius Steffen
KSKatharina Schmidt-Bleek
Katharina Schmidt-Bleek
CRCarsten Rendenbach
Carsten Rendenbach
The mandible (lower jaw) bone is aesthetically responsible for shaping the lower face, physiologically in charge of the masticatory movements, and phonetically accountable for the articulation of different phonemes. Thus, pathologies that result in great damage to the mandible severely impact the lives of patients. Mandibular reconstruction techniques are mainly based on the use of flaps, most notably free vascularized fibula flaps. However, the mandible is a craniofacial bone with unique characteristics. Its morphogenesis, morphology, physiology, biomechanics, genetic profile, and osteoimmune environment are different from any other non-craniofacial bone. This fact is especially important to consider during mandibular reconstruction, as all these differences result in unique clinical traits of the mandible that can impact the results of jaw reconstructions. Furthermore, overall changes in the mandible and the flap post-reconstruction may be dissimilar, and the replacement process of the bone graft tissue during healing can take years, which in some cases can result in postsurgical complications. Therefore, the present review highlights the uniqueness of the jaw and how this factor can influence the outcome of its reconstruction while using an exemplary clinical case of pseudoarthrosis in a free vascularized fibula flap.

6 October 2019 in International Endodontic Journal
Verified
Journal Article
Open access
PDF file
ASA. P. Soares
A. P. Soares
KBK. Bitter
K. Bitter
ALA. Lagrange
A. Lagrange
ARA. Rack
A. Rack
HSH. Shemesh
H. Shemesh
PZPaul Zaslansky
Paul Zaslansky
Aim: To assess the extent of gaps between root dentine and titanium or fibreglass post restorations following cementation with a self‐adhesive resin cement.Methodology: Fourteen root filled maxillary central incisors restored with prefabricated posts made of Fibreglass (n = 7) or Titanium (n = 7) and cemented with RelyX Unicem 2 were imaged by rapid, high‐resolution phase contrast‐enhanced micro‐CT (PCE‐CT) in a synchrotron X‐ray imaging facility (ID19, ESRF, 34 KeV, 0.65 µm pixel resolution). Reconstructions were used to measure canal, cement and post perimeters and cross‐sectional areas and interfacial gaps at 0.1 mm increments in the root canal space, along the cervical region of the tooth. Remnants of endodontic sealer (AH Plus), when present, were also quantified. Mann–Whitney and 2‐way ANOVA tests were used to compare findings within slices and between the two post groups. Pearson correlation coefficients (r) were determined between the interfacial gaps and the other measured parameters.Results: Clearly detectable gaps were found in 45% (±14%) of the interfaces between dentine and cement, along the canal in the cervical area of the tooth beneath the core. The length of interfacial gaps was moderately correlated to the canal cross‐sectional area, to the canal perimeter and to the canal area filled by cement (R = 0.52 ~ 0.55, P < 0.001). There was no significant difference between samples with fibreglass or titanium (P > 0.01). Both post types had defect‐free interfaces with cement. Endodontic sealer remnants were found on ~10% of the canal walls and were moderately correlated to the presence of gaps. Approximately 30% of the sealer‐affected interfaces exhibited no detachment between dentine, sealer and cement.Conclusions: Self‐adhesive cements had interfacial gaps along substantial regions of the root canal surface, which was not correlated with the amount of cement in the canal. PCE‐CT proved to be an excellent non‐destructive method to study root canal restorations of hydrated samples in 3D.

24 February 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
CSClaudius Steffen
Claudius Steffen
KSKay Sellenschloh
Kay Sellenschloh
MWMagdalena Willsch
Magdalena Willsch
ASAna Prates Soares
Ana Prates Soares
MMMichael Morlock
Michael Morlock
CRCarsten Rendenbach
Carsten Rendenbach

11 July 2024 in Acta Biomaterialia
Verified
Journal Article
Open access
PHPaulina Herzog
Paulina Herzog
CRCarsten Rendenbach
Carsten Rendenbach
MTMarta Turostowski
Marta Turostowski
AEAgnes Ellinghaus
Agnes Ellinghaus
ASAna Prates Soares
Ana Prates Soares
HFHeilwig Fischer
Heilwig Fischer
Magnesium as a biodegradable material offers promising results in recent studies of different maxillo-facial fracture models. To overcome adverse effects caused by the fast corrosion of pure magnesium in fluid surroundings, various alloys, and surface modifications are tested in animal models. In specified cases, magnesium screws already appeared for clinical use in maxillofacial surgery. The present study aims to compare the bone healing outcome in a non-load-bearing fracture scenario of the forehead in sheep when fixed with standard-sized WE43 magnesium fixation plates and screws with plasma electrolytic oxidation (PEO) surface modification in contrast to titanium osteosynthesis. Surgery was performed on 24 merino mix sheep. The plates and screws were explanted en-bloc with the surrounding tissue after four and twelve weeks. The outcome of bone healing was investigated with micro-computed tomography, histological, immunohistological, and fluorescence analysis. There was no significant difference between groups concerning the bone volume, bone volume/ total volume, and newly formed bone in volumetric and histological analysis at both times of investigation. The fluorescence analysis revealed a significantly lower signal in the magnesium group after one week, although there was no difference in the number of osteoclasts per mm2. The magnesium group had significantly fewer vessels per mm2 in the healing tissue. In conclusion, the non-inferiority of WE43-based magnesium implants with PEO surface modification was verified concerning fracture healing under non-load-bearing conditions in a defect model. STATEMENT OF SIGNIFICANCE: Titanium implants, the current gold standard of fracture fixation, can lead to adverse effects linked to the implant material and often require surgical removal. Therefore, degradable metals like the magnesium alloy WE43 with plasma electrolytic oxidation (PEO) surface modification gained interest. Yet, miniplates of this alloy with PEO surface modification have not been examined in a fracture defect model of the facial skeleton in a large animal model. This study shows, for the first time, the non-inferiority of magnesium miniplates compared to titanium miniplates. In radiological and histological analysis, bone healing was undisturbed. Magnesium miniplates can reduce the number of interventions for implant removal, thus reducing the risk for the patient and minimizing the costs.