The two-dimensional nature of mammography makes estimation of the overall breast density challenging, and estimation of the true patient-specific radiation dose impossible. Digital breast tomosynthesis (DBT), a pseudo-3D technique, is now commonly used in breast cancer screening and diagnostics. Still, the severely limited 3rd dimension information in DBT has not been used, until now, to estimate the true breast density or the patient-specific dose. This study proposes a reconstruction algorithm for DBT based on deep learning specifically optimized for these tasks. The algorithm, which we name DBToR, is based on unrolling a proximal-dual optimization method. The proximal operators are replaced with convolutional neural networks and prior knowledge is included in the model. This extends previous work on a deep learning-based reconstruction model by providing both the primal and the dual blocks with breast thickness information, which is available in DBT. Training and testing of the model were performed using virtual patient phantoms from two different sources. Reconstruction performance, and accuracy in estimation of breast density and radiation dose, were estimated, showing high accuracy (density <±3%; dose <±20%) without bias, significantly improving on the current state-of-the-art. This work also lays the groundwork for developing a deep learning-based reconstruction algorithm for the task of image interpretation by radiologists.
Purpose: The purpose of this study is to measure the effectiveness of local curvature measures as novel image features for classifying breast tumors.Methods: A total of 119 breast lesions from 104 noncontrast dedicated breast computed tomography images of women were used in this study. Volumetric segmentation was done using a seed‐based segmentation algorithm and then a triangulated surface was extracted from the resulting segmentation. Total, mean, and Gaussian curvatures were then computed. Normalized curvatures were used as classification features. In addition, traditional image features were also extracted and a forward feature selection scheme was used to select the optimal feature set. Logistic regression was used as a classifier and leave‐one‐out cross‐validation was utilized to evaluate the classification performances of the features. The area under the receiver operating characteristic curve (AUC, area under curve) was used as a figure of merit.Results: Among curvature measures, the normalized total curvature (CT) showed the best classification performance (AUC of 0.74), while the others showed no classification power individually. Five traditional image features (two shape, two margin, and one texture descriptors) were selected via the feature selection scheme and its resulting classifier achieved an AUC of 0.83. Among those five features, the radial gradient index (RGI), which is a margin descriptor, showed the best classification performance (AUC of 0.73). A classifier combining RGI and CT yielded an AUC of 0.81, which showed similar performance (i.e., no statistically significant difference) to the classifier with the above five traditional image features. Additional comparisons in AUC values between classifiers using different combinations of traditional image features and CT were conducted. The results showed that CT was able to replace the other four image features for the classification task.Conclusions: The normalized curvature measure contains useful information in classifying breast tumors. Using this, one can reduce the number of features in a classifier, which may result in more robust classifiers for different datasets.
1 November 2025 in Radiology: Artificial Intelligence
Objective . To develop a pathlength recovery method for material decomposition to address the challenge of nonunique mappings from fluence transmission to basis material pathlengths in dual-energy computed tomography (DECT) and implement it into a two-step algorithm to reconstruct material basis maps and virtual monochromatic images (VMIs). Approach. By formulating the DECT imaging model as a system of implicit equations to form level curves, we present a projection-based decomposition method that explicitly accounts for cases of fluence transmissions mapping to multiple material pathlength combinations. Using numerical simulations, we investigate the method’s capability to recover and analyze multiple pathlength solutions, resulting in improved material basis map reconstruction and VMI synthesis. Main Results. Examples of nonunique fluence mappings are demonstrated using polychromatic spectra (70 and 120 kV), demonstrating the potential for degraded material basis maps and VMI accuracy. We apply the pathlength recovery method to simulated DECT measurements of a digital phantom and demonstrate artifacts introduced by nonunique mappings if not properly resolved. A simulation with the VICTRE breast phantom is conducted to evaluate the quantitative accuracy of the method. Significance. This work develops a method for resolving nonunique fluence transmission to material pathlength mappings in DECT material decomposition while furthering the theoretical understanding of DECT system behaviors. Our method address efforts to enhance reliability and accuracy of material decomposition that has implications relevant to general spectral CT imaging.
The primal-dual hybrid gradient (PDHG) algorithm for solving convex optimization problems that arise in tomographic imaging is revisited. In particular, simplification of the selection of step-size parameters is developed for optimization problems with multiple terms, each containing a linear transform subject to splitting. This simplification maintains algorithm efficiency while avoiding massive grid searches for the optimal parameter settings. The PDHG framework is demonstrated on an image reconstruction problem for wide-angle digital breast tomosynthesis (DBT); use of the proposed optimization problem is enabled by the framework and it is demonstrated to have some advantage in quantitative accuracy of the reconstructed volume and in improving DBT depth resolution.
A realistic computer-simulation of a breast computed tomography (CT) system and subject is constructed. The model is used to investigate the optimal number of views for the scan given a fixed total X-ray fluence. The reconstruction algorithm is based on accurate solution to a constrained, TV-minimization problem, which has received much interest recently for sparse-view CT data.