8 January 2024 in Applied Physics Letters
We investigate the bulk passivation of the dilute bismide alloy InAsSbBi by plasma-assisted hydrogenation. InAsSbBi is of significant interest for mid- to long-wave infrared photodetection due to its bandgap flexibility and potential integration with heterostructured photodetector architectures. Epitaxially grown InAsSbBi samples are characterized by photoluminescence and time-resolved photoluminescence measurements for a range of hydrogenation conditions. Increases in the minority carrier lifetime of over 3× are reported, with no degradation over a period of months following the treatment. Photoluminescence measurements confirm that the hydrogenation process improves the InAsSbBi optical properties. These results offer a path toward the improved performance of InAsSbBi-based photodetectors and potentially other narrow bandgap semiconductor materials and material systems.
7 February 2025 in IEEE Transactions on Nuclear Science
The detector that converts X-ray intensity into a digitized electronic signal, processed into an image, often limits the performance of modern X-ray imaging systems, whether for medical, research, or industrial applications. Digital radiography (DR) uses the following two types of detectors: 1) indirect detectors, where a scintillating film converts X-rays into an optical signal read by an optical detector, and 2) direct detectors using semiconductors. Semiconductor X-ray detector technology typically uses a silicon wafer, an amorphous selenium (a-Se) film, or a relatively thin cadmium zinc telluride (CZT) crystal bump bonded to a readout platform. Although the use of a-Se and CZT improves the attenuation coefficient beyond that of silicon, a further increase in performance is highly desirable for improved imaging of higher-energy X-rays (greater than 20 keV). This article presents results on thallium bromide (TlBr) films coupled to a read-out integrated circuit (ROIC). TlBr, an attractive material for hard X-ray imaging due to its high atomic number and high density, achieves an image resolution of $20 \mu $ m as a 1 cm ${}^{2} \times 100$ - $\mu $ m-thick columnar film deposited on CMOS ROIC.
1 May 2026 in IEEE Transactions on Nuclear Science
This work explores the fabrication and characterization of X-ray imaging devices using a single-crystal TlBr sample (8 mm × 8 mm × 10 mm) and polycrystalline TlBr film (approximately 0.38-mm thick), both bonded to a Libra-1 Complementary Metal-Oxide-Semiconductor (CMOS) readout chip connected to the BrillianSe 1M readout system. The BrillianSe 1M, designed for X-ray radiography by KA Imaging, features a 10 mm × 11 mm readout chip with a 7.8 μm pixel pitch and a 7.8 mm × 7.8 mm active area. The work below describes the characterization of test and imaging devices. The characterization includes current-voltage (IV) curves and impedance spectra, longevity measurements of the X-ray response and leakage current, and imaging characterization with light-emitting diodes (LED) and X-rays. The resistivity of 3x1010 Ω-cm was estimated for a polycrystalline film sample. Following five weeks, the leakage current decreased from 670 to 6.4 nA, while the X-ray photocurrent decreased from 28 to 4 nA. Both the single crystal and polycrystalline imaging devices resolved 0.3-mm-diameter holes in a Tungsten composite mask when irradiated with 90 kVp (100 μA tube current) X-rays. Effects at the interface can be seen with both LED and X-rays. The images provide critical information for optimizing the fabrication process and device longevity.